Effects of Configurations of Internal Walls on the Threshold Value of Operation Hours for Intermittent Heating Systems
Source abstract
Abstract
The heating load of intermittent heating is not always lower than that of continuous heating for heat storage and release of internal walls. Therefore, the threshold value of daily operation hours exists, and is affected by the configuration of internal walls. A comparative study is performed between continuous and intermittent heating modes to investigate the threshold value of daily operation hours for different internal wall configurations by employing computational fluid dynamic (CFD) models. Meanwhile, field tests on the temperature distribution within a thermal mass was carried out to validate the simulation. The results show that the heating load index of intermittent heating is larger than that of continuous heating with increased amplitude ranging from 31.58% to 152.63%. The threshold value of daily operation hours is, respectively, 18.04 h, 15.80 h, 14.59 h, and 13.46 h for four internal wall configurations. Moreover, with the increase in the insulation level of internal walls, the threshold value of daily operation hours decreases. In addition, the results indicate that it is more economical to use continuous heating when the daily operation hours are more than the threshold values.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Building Energy and Comfort Optimization · Solar Energy Systems and Technologies · Heat Transfer and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Environmental Science and Engineering, Donghua University, Shanghai 201620, China
Funding
Fundamental Research Funds for the Central Universities
References (26)
Show source-provided references
1. Indoor thermal environment and energy saving for urban residential buildings in China10.1016/j.enbuild.2006.04.006 ↗
2. Analysis on urban residential energy consumption of Hot Summer & Cold Winter Zone in China10.1016/j.scs.2012.09.001 ↗
3. Investigation and analyses of residential heating in the HSCW climate zone of China: Status quo and key features10.1016/j.buildenv.2015.10.004 ↗
4. Low-energy envelope design of residential building in hot summer and cold winter zone in China10.1016/j.enbuild.2008.02.020 ↗
5. (2016). Code for Thermal Design of Civil Building, China Architecture and Building Press. (In Chinese).
6. Indoor thermal environment of urban residential buildings in China: Winter investigation in five major cities10.1016/j.enbuild.2003.09.015 ↗
7. Urban residential heating in hot summer and cold winter zones of China-Status, modeling, and scenarios to 203010.1016/j.enpol.2016.01.032 ↗
8. Energy flexibility of residential buildings using short term heat storage in the thermal mass10.1016/j.energy.2016.05.076 ↗
9. Comparative study of continuous versus intermittent heating for local residential building: Case studies in Jordan10.1016/j.enconman.2011.12.036 ↗
10. Wall heat loss from intermittently conditioned space-The dynamic influence of structural and operational parameters10.1016/j.enbuild.2005.11.012 ↗
11. Comparative analysis on thermal performance of different wall insulation forms under the air-conditioning intermittent operation in summer10.1016/j.applthermaleng.2017.11.042 ↗
12. Effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation10.1016/j.csite.2017.04.001 ↗
13. Effects of thermal insulation characteristics on energy consumption of buildings with intermittently operated air-conditioning systems under real time varying climate conditions10.1016/j.enbuild.2017.09.012 ↗
14. (2011). ANSYS FLUENT, 14.0 Theory Guide, ANSYS.
15. Characterization of flow field in a ventilation space and simulation of heat exchange between cows and their environment10.1016/S0306-4565(03)00007-X ↗
16. Performance and influence of numerical sub-models on the CFD simulation of free and forced convection in double-glazed ventilated façades10.1016/j.enbuild.2008.03.009 ↗
17. Numerical predictions of indoor climate in large industrial premises. A comparison between different k-ε models supported by filed measurements10.1016/j.buildenv.2006.11.005 ↗
18. Factors affecting the in situ measurement accuracy of the wall heat transfer coefficient using the heat flow meter method10.1016/j.enbuild.2014.11.005 ↗
19. Thermal performance and optimum insulation thickness of building walls with different structure materials10.1016/j.applthermaleng.2011.07.033 ↗
20. Design of an innovative enthalpy wheel based humidification system for polymer electrolyte fuel cell10.1016/j.ijhydene.2011.01.012 ↗
21. Study of factors affecting warm air spreading distance in impinging jet ventilation rooms using multiple regression analysis10.1016/j.buildenv.2017.03.044 ↗
22. Ministry of Housing and Urban-Rural Development of the People’s Republic of China (2010). Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Cold Winter Zone (JGJ134-2010), (In Chinese).
23. (2011). ANSYS FLUENT 14.0 User’s Guide, ANSYS.
24. Evaluation of various turbulence models for the prediction of the airflow and temperature distributions in atria10.1016/j.enbuild.2012.01.004 ↗
25. Heating energy consumption of impinging jet ventilation and mixing ventilation in large-height space: A comparison study10.1016/j.enbuild.2016.08.055 ↗
26. Investigation of winter indoor thermal environment and heating demand of urban residential buildings in China’s hot summer-cold winter climate region10.1016/j.buildenv.2016.02.022 ↗