journal article·2012-07

Evaluation of different methods to eliminate adherent endotoxin of polyethylene wear particles

Alexander C. Paulus, Christian Schröder, Birte Sievers, Jan Frenzel, Volkmar Jansson, Sandra Utzschneider

Wear· Volume 294-295
Publisher page

Abstract

Abstract Wear particles have to be cleaned from any substances, which could eventually lead to confounding effects in studies concerning the in vitro or in vivo biological activity of wear debris. Several observations have demonstrated that lipopolysaccharide (LPS) as a component of the outer membrane of gramnegative bacteria can modulate the cell response to wear debris. There are numerous methods described in the literature for the removal of LPS. But there is an exception for polyethylene particles, they cannot be treated with radiation and heating processes. There remain four possible methods: Cleaning the particles with sodium hydroxide or with acetic acid, washing them with ethanol or via using a demanding ultracentrifugation procedure. Thus we decided to compare the different methods in consideration of the remaining LPS level and their effects on the particle numbers and morphology. During the study several problems regarding these methods appeared: Either they could not remove the LPS below the demanded detection level, or the methods had influence on amount and morphology of the particles. Due to these findings the authors developed a new method based on ultracentrifugation. With this method the LPS could be removed as required, amount and morphology of the particles were not affected.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. The cellular and molecular biology of periprosthetic osteolysis10.1097/01.blo.0000238813.95035.1b ↗
2. P. Campbell, P. Doorn, F. Dorey, H.C. Amstutz, Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements, in: Proceedings of the Institution of Mechanical Engineers [H ], vol. 210, 1996, pp. 167–174.10.1243/PIME_PROC_1996_210_409_02 ↗
3. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns10.1097/01.blo.0000148783.20469.4c ↗
4. Macrophage cytokine response to particles and lipopolysaccharide in vitro10.1002/(SICI)1097-4636(20000315)49:4<469::AID-JBM5>3.0.CO;2-A ↗
5. Measurement and removal of adherent endotoxin from titanium particles and implant surfaces10.1002/jor.1100170603 ↗
6. The role of adsorbed endotoxin in particle-induced stimulation of cytokine release10.1016/S0736-0266(01)00179-6 ↗
7. Decontaminating particles exposed to bacterial endotoxin (LPS)10.1002/(SICI)1097-4636(19990905)46:3<434::AID-JBM17>3.0.CO;2-L ↗
8. Cytokine gene expression in polyethylene mediated macrophage activation10.1016/S0736-0266(01)00179-6 ↗
9. Current concepts in orthopaedic biomaterials and implant fixation
10. Mechanism of lipopolysaccharide-triggered junB activation in a mouse macrophage-like cell line (J774)10.1016/S0021-9258(18)82418-8 ↗
11. Lipopolysaccharide dependent cellular activation10.1111/j.1600-0765.1997.tb01388.x ↗
12. Does endotoxin contribute to aseptic loosening of orthopedic implants?10.1002/jbm.b.30150 ↗
13. Administration of pamidronate alters bone-titanium attachment in the presence of endotoxin-coated polyethylene particles10.1002/jbm.b.30803 ↗
14. Accumulation of LPS by polyethylene particles decreases bone attachment to implants10.1002/jor.20038 ↗
15. Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes10.1016/S0142-9612(02)00510-0 ↗
16. Periprosthetic osteolysis: induction of vascular endothelial growth factor from human monocyte/macrophages by orthopaedic biomaterial particles10.1359/jbmr.2003.18.9.1573 ↗
17. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles10.1016/j.biomaterials.2003.10.054 ↗
18. A.L. Galvin, J.L. Tipper, L.M. Jennings, M.H. Stone, Z.M. Jin, E. Ingham, Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations, in: Proceedings of the Institution of Mechanical Engineers [H ], vol. 221, 2007, pp. 1–10.10.1243/09544119JEIM99 ↗
19. Wear of contemporary total knee replacements—a knee simulator study of six current designs10.1016/j.clinbiomech.2009.04.007 ↗
20. Comparison of three joint simulator wear debris isolation techniques: acid digestion, base digestion, and enzyme cleavage10.1002/1097-4636(200108)56:2<245::AID-JBM1091>3.0.CO;2-T ↗
21. Particle analysis for the determination of UHMWPE wear10.1002/jbm.b.30213 ↗
22. International Standard ISO 17853, Wear of implant particles—Polymer and metal wear particles—Isolation, characterization and quantification, 2008.
23. Removal of endotoxin during purification of poly(3-hydroxybutyrate) from gram-negative bacteria10.1128/AEM.65.6.2762-2764.1999 ↗
24. Wear of crosslinked polyethylene under different tribological conditions10.1007/s10856-006-7309-z ↗
25. The effects of lubricant composition on in vitro wear testing of polymeric acetabular components10.1002/jbm.b.10077 ↗
26. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing10.1243/095441105X34392 ↗
27. Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments10.1055/s-2004-822589 ↗
28. Murine model of prosthesis failure for the long-term study of aseptic loosening10.1002/jor.20342 ↗
29. Comparison of the response of primary human blood monocytes and the U937 human monocytic cell line to two different sizes of alumina ceramic particles10.1016/j.orthres.2003.10.022 ↗
30. The balance between endotoxin accumulation and clearance during particle-induced osteolysis in murine calvaria10.1002/jor.20289 ↗
31. Titanium particles that have undergone phagocytosis by macrophages lose the ability to activate other macrophages10.1002/jbm.b.30913 ↗
32. Endotoxin contamination of particles produces misleading inflammatory cytokine responses from macrophages in vitro10.1302/0301-620X.84B2.0840295 ↗