The European Yield Model (EYM) for laterally loaded timber connections with smooth nails
Source abstract
Abstract
The European Yield Model (EYM) is a commonly accepted procedure to calculate the capacity of laterally loaded connections with dowel type fasteners. The standard procedure is specified in EC5 (EN 1995-1-1 2004) and uses characteristic values as input parameters for the calculation of characteristic values of the resistance of the connection. These characteristic values are the basis for an engineering design of structures. Nevertheless, there are situations, e.g. the design of a test set-up or a pushover analysis in earthquake engineering, when mean values of the resistance of a timber connection are needed. In this context, analytical equations and mechanical models were assessed on two levels by comparing theoretical values to experimental results. The first part of the research considered all the input parameters. The mechanical definition of the plastic moment proved to be more appropriate than the definition of a modified plastic moment according to EC5 for the determination of the yield moment of nails. On the other hand, it was confirmed that the embedment strength of Norway spruce softwood can be predicted reliably and slightly conservatively according to code regulations given by EC5. The definition for the withdrawal strength according to EC5 also seems to define a conservative lower boundary. The situation is not so clear for the embedment strength of oriented strand board (OSB). Test results are very scarce and do not account for the inhomogeneity regarding the thickness of the boards with higher density at the surfaces, which is the section where contact forces are transferred. In the second part, over 110 specimens considering eight different types of nailed connections were tested to assess different calculation procedures. The study focused on nailed connections with OSB and solid timber. This combination together with smooth nails as fasteners is very common in Europe for light-frame structures, especially in areas of low and medium seismicity because they exhibit large deformation capacity without losing strength. On the level of mean values, relationships are found between 1.00 and 1.47 for experimental results over calculated resistance, and it was found that the EYM is more conservative when the thickness of the sheathing is 10 mm instead of 18 mm, which means, that the expected failure mechanism changes from one to two plastic hinges. The findings are approximately the same if the relationship is studied on the level of characteristic values. Here, the relationship of values from experimental investigations over analytical calculation lays between 1.27 and 1.58 for a mechanism with one plastic hinge and between 0.90 and 1.12 for a mechanism with two plastic hinges. Based on these results, the question arises, if the EYM is the appropriate tool to predict the capacity of laterally loaded connections if comparatively large deformations occur between the connected parts. This question should be studied more detailed in the future.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Civil and Structural Engineering Research · Engineering and Materials Science Studies · Probabilistic and Robust Engineering Design
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Timber Engineering, University of Kassel, Kassel, Germany
Dr. Böttcher & Dr. Schick, Consulting Engineers, Wetter-Amönau, Germany
References (37)
Show source-provided references
1. Blass H. J. · Proc. International RILEM Symposium on Joints in Timber Structures · 2001 · 71
2. CSA 086-09 (2009) Engineering design in wood. Canadian Standards Association.
3. DIN 1052 T2 (1988) Holzbauwerke; Mechanische Verbindungen. European Committee for Standardisation, Brussels, Belgium.
4. 10.1007/BF0261922410.1007/BF02619224 ↗
5. EN 13183-1:2002. Moisture content of a piece of sawn timber. Part 1: Determination by oven dry method. European Committee for Standardisation, Brussels, Belgium.
6. EN 1382:2016. Timber structures – Test methods – Withdrawal capacity of timber fasteners. European Committee for Standardisation, Brussels, Belgium.
7. EN 14358:2016. Timber structures – Calculation and verification of characteristic values. European Committee for Standardisation, Brussels, Belgium.
8. EN 1995-1-1:2004. Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings. EN 1995-1-1:2004+AC:2006+A1:2008. European Committee for Standardisation, Brussels, Belgium.
9. EN 26891:1991. Timber structures; Joints made with mechanical fasteners; General principles for the determination of strength and deformation characteristics. European Committee for Standardisation, Brussels, Belgium.
10. EN 338:2016. Structural Timber – Strength Classes. European Committee for Standardisation, Brussels, Belgium.
11. EN 383:2007. Timber Structures – Test methods – Determination of embedment strength and foundation values for dowel type fasteners. European Committee for Standardisation, Brussels, Belgium.
12. EN 384:2016. Structural timber – Determination of characteristic values of mechanical properties and density. European Committee for Standardisation, Brussels, Belgium.
13. EN 409:2009. Timber structures – Test methods – Determination of the yield moment of dowel type fasteners. European Committee for Standardisation, Brussels, Belgium.
14. EN 12369-1:2001. Wood-based panels — Characteristic values for structural design — Part 1: OSB, particleboards and fibreboards. European Committee for Standardisation, Brussels, Belgium.
15. Franke, S. and Magnière, N. (2014) Discussion of testing and evaluation methods for the embedment behaviour of connections. Proceedings of the International Network on Timber Engineering Research. INTER/47-7-1, Bath, UK.
16. 10.1016/j.conbuildmat.2019.11670210.1016/j.conbuildmat.2019.116702 ↗
17. Hoppe M. · Draht · 1991 · 42 · 885
18. Hübner, U. (2014) Mechanische Kenngrößen von Buchen- Eschen-und Robinienholz für lastabtragende Bauteile. Verlag d. Technischen Universität Graz.
19. 10.1016/j.conbuildmat.2019.05.08710.1016/j.conbuildmat.2019.05.087 ↗
20. JCSS, J. (2006) Probabilistic model code. Joint Committee on Structural Safety.
21. Johansen K. W. · Int Assoc Bridge Struct Eng · 1949 · 9 · 249
22. 10.1016/j.engstruct.2011.07.02410.1016/j.engstruct.2011.07.024 ↗
23. Kessel, M. (1998) Vergleichende Betrachtungen europäischer Bauproduktnormen mit nationalen Bestimmungen: Teilprojekt: Bestimmung der Lochleibungsfestigkeit nach EN 383 für verschieden Beplankungsmaterialien. Fraunhofer-IRB-Verlag.
24. Leijten, A., Köhler, J. and Jorissen, A. (2004) Review of probability data for timber connections with dowel-type fasteners. In: Proc. of the CIB-W18 Meeting 37, Edinburgh, UK, Paper No. CIB-W18/37-7-13.
25. 10.1002/bapi.20091003210.1002/bapi.200910032 ↗
26. NZS 3603 (1993) Code of Practice for Timber Design. New Zealand Standard.
27. 10.1016/j.engstruct.2018.06.07110.1016/j.engstruct.2018.06.071 ↗
28. 10.1016/j.engstruct.2019.01.03410.1016/j.engstruct.2019.01.034 ↗
29. Seim, W. and Schick, M. (2018) Overstrength assessment for timber connections and wall elements –comparison of different approaches. In Proceedings of World Conference on Timber Engineering.
30. SIA 265 (2012) Timber structures. Schweizerischer Ingenieur- und Architektenverein.
31. SIA 265/1 (2009) Timber structures – Supplementary Specifications. Schweizerischer Ingenieur- und Architektenverein.
32. Steidl C. M. · Forest Products Journal · 2003 · 53 · 72
33. 10.1617/s11527-017-1124-510.1617/s11527-017-1124-5 ↗
34. 10.1080/17480272.2016.122638210.1080/17480272.2016.1226382 ↗
35. 10.1007/BF0261326910.1007/BF02613269 ↗
36. Whale L. R. J. · Journal of the Institute of Wood Science · 1989 · 11 · 156
37. 10.1007/BF0268402710.1007/BF02684027 ↗