journal article·2012-03

Failure analysis of a liquid natural gas (LNG) containment system – Bending failure of plywood component

A. Arswendy, Torgeir Moan

Publisher page

Abstract

Abstract The main load-carrying component of the containment system of membrane gas carriers is made of plywood. One of the failure modes of the containment system due to violent liquid loading inside the tank is bending the plywood plate. A systematic study of the plywood bending failure is conducted by means of experiments and finite element (FE) methods. The objective is to propose an FE model that can replicate the nonlinear tests results of the plywood bending failure. The FE software ABAQUS has been utilized as a basis for this study. The material is modelled by linear elasticity combined with damage initiation using Hashin's theory. The brittle behaviour is indicated by linear softening. The softening is modelled by a fracture energy approach. The sensitivity study of the damage parameter on ultimate bending load is conducted. The numerical results from FE models are compared with the test results. A nonlinear material and FE model of plywood that could demonstrate the brittle failure is proposed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Response to Dynamic Loads · Mechanical Behavior of Composites · Fluid Dynamics Simulations and Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Arswendy , A. , Liasjoe , O. and Moan , T. 2010a Comparative study of FE models of LNG containment system no.96 . 20th International Conference on Offshore and Polar Engineering , Beijing China , June 20–26.
2. Arswendy , A. , Liasjoe , O. and Moan , T. 2010b The effect of inner steel hull flexibility on the responses of the LNG containment system under static loads . 20th International Conference on Offshore and Polar Engineering , Beijing , China , June 20–26 .
3. American Bureau of Shipping , 2006 Guidance notes on strength assessment of membrane-type LNG containment system under sloshing loads , Houston , TX , USA .
4. Bazant Z. P. · Materials and Structures, RILEM · 1983 · 16 · 155
5. 10.1007/BF0035623810.1007/BF00356238 ↗
6. Curry W. T. · 1954
7. Det Norske Veritas , 2006 Sloshing analysis of LNG membrane tanks . DNV Classification Notes , No. 30.9.
8. EN 789 , 1996 Timber structures – test methods – determination of mechanical properties of wood-based panels.
9. EN 1058 , 1996 Wood-based panels determination of characteristic values of mechanical properties and density.
10. Gaztransport and Technigaz , 2005 No. 96 membrane system for LNG integrated tank. Accessed 10 August 2010, available at:http://www.gtt.fr
11. Hashin Z. · Failure Criteria for Unidirectional Fiber Composites · 1980 · 47 · 329
12. Llyod's Register 2009 Sloshing assessment guidance document for membrane tank LNG operations .ShipRight design and construction v.2.0.
13. 10.1016/j.biosystemseng.2007.10.00410.1016/j.biosystemseng.2007.10.004 ↗
14. Simulia 2008 ABAQUS documentation .
15. UPM 2008 Handbook of Finnish plywood . Accessed 10 August 2010, available atwww.wisa.com