journal article·2026-07-22

Optimizing fire resistance in timber door frames using calcium silicate barriers

Anand Nandanwar, B. S. Mamatha

Publisher page

Abstract

In most fire-rated door systems, emphasis is primarily placed on the door shutter, while the contribution of the door frame to overall fire performance is often overlooked. This study investigates the fire resistance of composite timber door frames reinforced with calcium silicate (Cal-Sil) boards of varying thicknesses. Timber sections with densities ranging from 400 to 800 kg/m³ were combined with 6, 9, and 12 mm Cal-Sil barriers and evaluated through furnace exposure, post-fire mechanical testing, and full-scale fire resistance tests. Performance parameters included mass loss, char depth, burning rate, residual compressive strength, screw-withdrawal strength, delamination behaviour, effectiveness of adhesive bonding and mechanical fastening, etc. Results showed significant effects of timber density (p = 0.004), barrier thickness (p = 0.001), and their interaction (p = 0.02) on fire performance. Full-scale testing indicated that unprotected timber frames failed after approximately 50 min, whereas frames protected with 6 and 9 mm Cal-Sil barriers achieved fire resistance ratings of about 90 and 120 min, respectively. Regression analysis revealed that fire endurance increased by approximately 7.6 min for each millimetre increase in barrier thickness (R² = 0.993). A 9 mm Cal-Sil barrier combined with medium-density timber and mechanical fastening provided the optimum performance.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on concrete materials · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

ICFRE – Institute of Wood Science and Technology

References (28)

Show source-provided references
1. Abdul Rashid, S., 1987. Fire performance of timber materials: a study of charring rates and fire resistance. Building Research Journal, 45 (3), 123–135.
2. 10.1016/j.jobe.2026.11550010.1016/j.jobe.2026.115500 ↗
3. AS 1530.4, 2014, Methods for fire tests on building materials, components and structures—fire-resistance tests for elements of construction. Sydney: Standards Australia.
4. 10.1016/j.firesaf.2015.02.00410.1016/j.firesaf.2015.02.004 ↗
5. ASTM E119, 2023, Standard test methods for fire tests of building construction and materials. West Conshohocken, PA: ASTM International.
6. Babrauskas, V., 2005. Fire behavior of wood and timber construction components. Fire Safety Journal, 43 (6), 403–412.
7. Brentano, S., 2015. Innovative materials and technologies in building construction. Journal of Architectural Engineering, 12 (4), 225–238.
8. BS 476: Part 22, 1987, Fire tests on building materials and structures. methods for determination of the fire resistance of non-load bearing elements of construction. London: British Standards Institution.
9. BS EN 1634-1, 2018, Fire resistance test for door and shutter assemblies and openable windows. London: British Standards Institution.
10. CAN/ULC-S101, 2019, Standard methods of fire endurance tests of building construction and materials. Ottawa, ON: Underwriters Laboratories of Canada.
11. Carlo, U., et al., 2008. A segurança contra incêndio no Brasil. São Paulo: Projeto Editora.
12. EN 13501-1, 2018, Fire classification of construction products and building elements – part 1: classification using data from reaction to fire tests. Brussels: CEN. European Norms.
13. 10.1016/j.tws.2017.02.00510.1016/j.tws.2017.02.005 ↗
14. Hall, W., 1982. Charring rates of different timber species in fire-rated applications. Timber Engineering, 25 (2), 32–40.
15. 10.1111/jace.1788110.1111/jace.17881 ↗
16. IS 1708, 1983, Methods of testing of small clear specimens of timber. New Delhi: Bureau of Indian Standards.
17. IS 3614, 2021, Metallic and non-metallic fire check doors –resistance test and performance criteria. New Delhi: Bureau of Indian Standards.
18. ISO 3008, 2007, Fire-resistance tests – door and shutter assemblies. Geneva: International Organization for Standardization.
19. ISO 834-1, 2025, Fire-resistance tests—elements of building construction—part 1: general requirements. Geneva: International Organization for Standardization.
20. Izydorczyk, D., et al., 2017. Doors with specific fire resistance class. Procedia Engineering, 172, 417–425.10.1016/j.proeng.2017.02.010 ↗
21. Nandanwar, A., Kiran, M.C., and Rajulu, K.C.V., 2020. Effect of density on rate of burning of wood used in frame of fire rated doors. International Journal of Civil and Structural Engineering Research, 8 (1), 56–61.
22. Pacheco, A., 2018. The influence of wood density on carbonization rates and fire performance. Journal of Wood Science, 47 (2), 111–120.
23. Pinto, J., and Calil, A., 2002. Reaction-to-fire testing and material contributions to fire spread. Fire Research, 9 (1), 45–58.
24. Purser, D., 2000. Flame retardants in building materials: A safety measure against fire spread. Building Materials Safety Review, 14 (5), 62–72.
25. 10.1080/01694243.2025.256391010.1080/01694243.2025.2563910 ↗
26. Silva, P., 2010. Fire resistance of composite door materials. Journal of Fire Safety Science, 34 (3), 112–128.
27. Troitzsch, U., 1983. The role of flame-retardant treatments in fire prevention. Fire Technology, 21 (6), 391–402.
28. 10.1155/2015/64206110.1155/2015/642061 ↗