Source abstract
Abstract
This study presents a simple electrochemical DNA biosensor to accurately detect Klebsiella pneumoniae DNA. The biosensor uses glycine functionalized iron oxide nanoparticles (glycine@Fe3O4) to capture Klebsiella pneumoniae DNA. The as-synthesized nanoparticles were characterized using X-ray diffraction, X-ray photoelectron spectroscopy, Raman spectroscopy, and transmission electron microscopy, and created a sensitive electrode surface that produced strong electrochemical signals when DNA attached. Electrochemical techniques, including cyclic voltammetry and square wave voltammetry, were used to develop a biosensor for detecting Klebsiella pneumoniae DNA. The biosensor showed limits of detection of 3.27 nM in the 30-90 nM range and 3.94 nM in the 120-270 nM range, with limits of quantification of 3.90 nM and 11.95 nM, respectively. The sensitivity, determined from calibration curves, was 0.1009 μA nM-1 for the low range and 0.0838 μA nM-1 for the high range. The biosensor demonstrated high sensitivity and selectivity, effectively distinguishing the analyte from interferents like albumin and folic acid. Molecular docking showed strong DNA binding (-6 kcal mol-1). Lab tests confirmed detection of Klebsiella pneumoniae antimicrobial resistance genes (SHV, TEM, CTX-M, OXA-1) via PCR-based gel electrophoresis. This easy-to-use non-enzymatic biosensor offers fast, accurate, rapid, sensitive, and specific Klebsiella pneumoniae DNA detection, valuable for point-of-care diagnostics and antimicrobial resistance monitoring.
Affiliations
Department of Medical Biotechnology and Stem Cells and Regenerative Medicine, Centre for Interdisciplinary Research, D. Y. Patil Education Society (Deemed to be University), Kolhapur, Maharashtra, 416006, India
School of Nanoscience and Biotechnology, Shivaji University, Kolhapur, Maharashtra, 416004, India
Symbiosis Centre for Nanoscience and Nanotechnology (SCNN), Symbiosis International (Deemed University), Lavale, Pune, 412115, India
Department of Electronics, Shivaji University, Kolhapur 416004, India
Dr Homi Bhabha State University, 15, Madam Cama Road, Mumbai 400032, India
Smart Materials, Nano SYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, Sønderborg 6400, Denmark
Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea
Global Innovative Center of Advanced Nanomaterials, College of Engineering, Science and Environment, University of Newcastle, Callaghan, NSW, 2308, Australia
Funding
D.Y. Patil Education Society Institution Deemed to be University Kolhapur · National Research Foundation of Korea
References (47)
Show source-provided references
18. Khoshroo · BioImpacts · 2022 · 12 · 567
21. Villalonga · Magn. Nanopart.-Hybrid Mater. · 2021 · 1 · 679
24. Chen · Lab Chip · 2024 · 15 · 67
25. Zhang · Biosensors · 2023 · 15 · 140
26. Kumar · Sensors · 2023 · 25 · 1212
27. Lee · Sensors · 2022 · 22 · 345
28. Ahmed · Sensors · 2025 · 25 · 2124
29. Nagdeve · J. Biol. Eng. · 2025 · 14 · 98
30. Singh · SpringerLink · 2024 · 12 · 207
32. Wang · Sensors · 2022 · 15 · 92
33. Patel · Sensors · 2024 · 20 · 287
34. Lima · Biosensors · 2025 · 15 · 300
35. Varnakavi · Sensors · 2021 · 22 · 1400
36. A.Papreja and K.Saxena , Enzyme-based biosensors for rapid electrochemical analysis: Cyclic voltammetry focus , AIP Publ. , 2023 , vol. 45, 5 , p. 78
38. Panta · J. Mater. Sci. Eng. · 2015 · 5 · 1
40. Sudakar · J. Phys.: Condens. Matter · 2006 · 19 · 026212
41. Abouzied · Egypt. J. Nat. Toxins. · 2007 · 4 · 51
42. Villalonga · Magn. Nanopart.-Hybrid Mater. · 2021 · 1 · 679