Influence of Fly Ash as Cement Replacement on the Properties of Recycled Aggregate Concrete
Source abstract
Abstract
The use of high percentages of recycled aggregates in concrete would usually worsen the concrete properties. This paper tries to address the deficiency of the use of recycled aggregates by systematically presenting results on the influence of incorporating Class F fly ash on concrete properties. In this study, two series of concrete mixtures were prepared with water-to-binder (W/B) ratios of 0.45 and 0.55. The recycled aggregate was used as 0, 20, 50, and 100% by weight replacements of natural aggregate. In addition, fly ash was used as 0, 25, and 35% by weight replacements of cement. The results showed that the compressive strengths, tensile strengths, and static modulus of elasticity values of the concrete at all ages decreased as the recycled aggregate and the fly ash contents increased. Further, an increase in the recycled aggregate content decreased the resistance to chloride ion penetration and increased the drying shrinkage and creep of concrete. Nevertheless, the use of fly ash as a substitute for cement improved the resistance to chloride ion penetration and decreased the drying shrinkage and creep of the recycled aggregate concrete. The results showed that one of the practical ways to utilize a high percentage of recycled aggregate in structural concrete is by incorporating 25–35% of fly ash as some of the drawbacks induced by the use of recycled aggregates in concrete could be minimized.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Recycled Aggregate Concrete Performance · Innovative concrete reinforcement materials · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Associate, Dept. of Civil and Structural Engineering, The Hong Kong Polytechnic Univ., Hum Hom, Kowloon, Hong Kong.
Professor, Dept. of Civil and Structural Engineering, The Hong Kong Polytechnic Univ., Hum Hom, Kowloon, Hong Kong.
References (21)
Show source-provided references
1. Reincarnation of concrete
2. ASTM. (1997). “Standard test method for electrical indication of concrete’s ability to resist chloride ion penetration.” ASTM C 1202 Philadelphia.
3. ASTM. (2002a). “Standard test method for creep of concrete in compression.” ASTM C 512 Philadelphia.
4. ASTM. (2002b). “Standard test method for static modulus of elasticity and Poisson’s ratio of concrete in compression.” ASTM C 469 Philadelphia.
5. 10.1016/S0008-8846(03)00247-310.1016/S0008-8846(03)00247-3 ↗
6. British Standards Institution (BSI). (1970). “Methods of testing concrete for other than strength.” BS 1881 Part 5 London.
7. British Standards Institution (BSI). (1985). “Specification for aggregates from natural sources for concrete.” BS 882 London.
8. 10.1139/l04-08810.1139/l04-088 ↗
9. 10.1680/istbu.1999.3156810.1680/istbu.1999.31568 ↗
10. Investigations of the engineering properties of OPC/pulverized-fuel ash concrete: Deformation properties
11. Relationship between gas absorption and the shrinkage and creep of recycled aggregate concrete
12. 10.1016/S0008-8846(00)00250-710.1016/S0008-8846(00)00250-7 ↗
13. Mindess S. · 2003
14. 10.1016/j.cemconres.2004.03.01810.1016/j.cemconres.2004.03.018 ↗
15. Neville A. M. · 1995
16. 10.1016/S0008-8846(01)00653-610.1016/S0008-8846(01)00653-6 ↗
17. 10.1061/(ASCE)0899-1561(2003)15:5(443)10.1061/(ASCE)0899-1561(2003)15:5(443) ↗
18. 10.1016/S0008-8846(03)00186-810.1016/S0008-8846(03)00186-8 ↗
19. Resistance to freezing and thawing of recycled aggregate concrete
20. 10.1016/j.cemconres.2004.10.02510.1016/j.cemconres.2004.10.025 ↗
21. Drying shrinkage behavior of recycled aggregate concrete