Uniaxial Compressive Strength and Stiffness of Field-Extracted and Laboratory-Constructed Masonry Prisms
Source abstract
Abstract
Masonry material characteristics such as compression stress-strain behavior and the relationships between brick, mortar, and masonry compressive strengths are required for the detailed analysis and assessment of masonry structures. These properties have been investigated previously, but most past studies were laboratory based and did not include within their scope the testing of existing masonry buildings. This study aimed to characterize the compressive strength and the compression stress-strain relationship of vintage clay brick masonry used in New Zealand unreinforced masonry (URM)-bearing wall buildings that were generally constructed between 1880 and 1940. Testing was performed on 45 masonry prisms that were extracted from eight New Zealand historic URM buildings and on 75 masonry prisms that were constructed in the laboratory using 14 different brick/mortar combinations. It was found that the laboratory-constructed sample test results adequately replicated those from the field-extracted samples, and predictive equations and a numerical compression stress-strain model for use in the detailed seismic assessment of URM buildings were developed based on the experimental results.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Hygrothermal properties of building materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ph.D. Student, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Private Bag 92019, Auckland 1010, New Zealand (corresponding author).
Principal, Biggs Consulting Engineering, Troy, NY 12180.
Associate Professor, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Private Bag 92019, Auckland 1010, New Zealand.
References (30)
Show source-provided references
1. Statistical analysis of compressive strength of clay brick masonry: Testing
2. ASTM. (1997). “Standard test method for Young’s modulus tangent modulus and chord modulus.” E111-97 West Conshohocken PA.
3. ASTM. (2003a). “Standard test method for compressive strength of masonry prisms.” C1314-03b West Conshohocken PA.
4. ASTM. (2003b). “Standard test methods for sampling and testing brick and structural clay tile.” C67-03a West Conshohocken PA.
5. ASTM. (2008a). “Standard specification for mortar for unit masonry.” C270-08a West Conshohocken PA.
6. ASTM. (2008b). “Standard test method for compressive strength of hydraulic cement mortars (using 2-in. or [50-mm] cube specimens).” C109/C109M-08 West Conshohocken PA.
7. Canadian Standards Association. (2004). Design of masonry structures S304.1 Mississauga ON Canada.
8. Strength of brick masonry prisms in compression
9. Drysdale R. Hamid A. and Baker L. (1999). Masonry structures: Behaviour and design The Masonry Society Boulder CO.
10. European Committee for Standardization (CEN). (2005). “Eurocode 6: Design of masonry structures—Part 1-1: General rules for reinforced and unreinforced masonry structures.” EN1996-1-1:2005 Brussels.
11. Federal Emergency Management Agency. (1999). “Evaluation of earthquake damaged concrete and masonry wall buildings basic procedures manual ATC-43.” FEMA 306 Applied Technology Council (ATC-43 Project) Redwood City CA.
12. 10.1617/s11527-006-9141-910.1617/s11527-006-9141-9 ↗
13. 10.1007/978-1-349-14827-110.1007/978-1-349-14827-1 ↗
14. 10.1061/(ASCE)0899-1561(2007)19:9(728)10.1061/(ASCE)0899-1561(2007)19:9(728) ↗
15. Uniaxial compressive stress-strain model for clay brick masonry
16. 10.1061/JSDEAG.000295710.1061/JSDEAG.0002957 ↗
17. The effect of slenderness and end restraint on the behavior of masonry prisms—A literature review
18. Lenczner D. · 1972
19. Lumantarna R. · 2012
20. 10.1016/j.compositesb.2006.11.00410.1016/j.compositesb.2006.11.004 ↗
21. Masonry Standards Joint Committee. (2002). “Building code requirements for masonry structures.” ACI 530-02/ASCE 5-02/TMS 402-02 America Concrete Institute Structural Engineering Institute of the American Society of Civil Engineers The Masonry Society Detroit.
22. 10.1016/j.conbuildmat.2005.08.02110.1016/j.conbuildmat.2005.08.021 ↗
23. New Zealand Society for Earthquake Engineering. (2006). Assessment and improvement of the structural performance of buildings in earthquakes Wellington New Zealand.
24. Oakdale Engineering. (2010). DataFit 9.0 Oakdale CA 〈http://www.oakdaleengr.com/〉 (Jan. 14 2014).
25. Ordinanza del Presidente del Consiglio dei Ministri (OPCM) · 2005
26. 10.1002/978047017284110.1002/9780470172841 ↗
27. Stress-strain curves for unconfined and confined concrete masonry
28. 10.5459/bnzsee.43.3.182-20110.5459/bnzsee.43.3.182-201 ↗
29. 10.1061/(ASCE)0899-1561(2005)17:2(229)10.1061/(ASCE)0899-1561(2005)17:2(229) ↗
30. Seible F. · 1991 · 281