journal article·2001-04

Delamination Failure in Concrete Beams Retrofitted with a Bonded Plate

Christopher K. Y. Leung

Publisher page

Abstract

Concrete beams are often retrofitted with bonded steel or composite plates. The failure of the retrofitted member is usually due to delamination of the plate from the beam. Delamination can occur either at the end of the reinforcing plate or at the location of a crack in the concrete beam. This paper will focus on the analysis of delamination initiated at the mouth of a flexural crack. When loading is applied, the flexural crack tends to open and hence induces high interfacial shear stress that may result in delamination. The relation between interfacial shear stress and applied moment is affected by many material and geometric parameters. In this study, the bridging stress in the bonded plate and the maximum interfacial shear stress τmax are first related to the crack mouth opening. A fracture mechanics based analysis is then carried out to obtain the crack mouth opening and τmax for a given applied moment. Through a systematic parametric analysis, the effect of various parameters on τmax is deduced. A combination of parameters that will increase τmax, and hence increase the likelihood of delamination, can hence be identified and avoided in design.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Assoc. Prof., Dept. of Civ. Engrg., Hong Kong Univ. of Sci. and Technol., Kowloon, Hong Kong.

References (15)

Show source-provided references
1. Bogy D. B. ( 1971). “On the plane elastostatic problem of a loaded crack terminating at a material interface.” J. Appl. Mech. 38 911–918.10.1115/1.3408975 ↗
2. Bosco C. and Carpinteri A. ( 1992). “Fracture mechanics evaluation of minimum reinforcement in concrete structures.” Applications of fracture mechanics to reinforced concrete A. Carpinteri ed. Elsevier Applied Science London 231–265.
3. Kaar P. H. and Mattock A. H. ( 1963). “High strength bar as concrete reinforcement Part 4. Control of cracking.” J. PCA R&D Labs 7(1) 42–53.
4. Malik A. M. Saadatmanesh H. and Ehsani M. R. ( 1998). “Prediction of failure load of R/C beams strengthened with FRP plate due to stress concentration at the plate end.” ACI Struct. J. 95(1) 142–152.10.14359/534 ↗
5. Meier U. ( 1997). “Post strengthening by continuous fiber laminates in Europe.” Non-metallic (FRP) reinforcement for concrete structures Vol. 1 Japan Concrete Institute 41–56.
6. Meier U. Deuring M. Meier H. and Schwegler G. ( 1992). “Strengthening of structures with CFRP laminates: Research and applications in Switzerland.” Advanced composite materials in bridges and structures Canadian Society for Civil Engineering 243–251.
7. Neale K. W. and Laboissiere P. ( 1997). “State-of-the-art report on retrofitting and strengthening by continuous fibre in Canada.” Non-metallic (FRP) reinforcement for concrete structures Vol. 1 Japan Concrete Institute 25–40.
8. Rooke D. P. and Jones D. A. ( 1978). “Stress intensity factors in fretting fatigue.” J. Strain Anal. 119(1) 1–7.10.1243/03093247V141001 ↗
9. 10.1061/(ASCE)0733-9445(1991)117:11(3417)10.1061/(ASCE)0733-9445(1991)117:11(3417) ↗
10. Taljsten B. ( 1996). “Strengthening of concrete prisms using the plate-bonding technique.” Int. J. Fracture 82 253–266.10.1007/BF00013161 ↗
11. 10.1061/(ASCE)0899-1561(1997)9:4(206)10.1061/(ASCE)0899-1561(1997)9:4(206) ↗
12. Triantafillou T. C. and Plevris N. ( 1992). “Strengthening of R/C beams with epoxy-bonded fiber composite materials.” Mat. and Struct. Paris 25 201–211.10.1007/BF02473064 ↗
13. 10.1061/(ASCE)0733-9445(1991)117:11(3434)10.1061/(ASCE)0733-9445(1991)117:11(3434) ↗
14. Wu X. R. and Carlsson A. J. ( 1991). Weight functions and stress intensity factor solutions Pergamon Oxford England.
15. Wu Z. Matsuzaki T. and Tanabe K. ( 1997). “Interface crack propagation in FRP-strengthened concrete structures.” Non-metallic (FRP) reinforcement for concrete structures Vol. 1 Japan Concrete Institute 319–326.