journal article·1993-02

Characterization of Polyester Polymer and Polymer Concrete

C. Vipulanandan, E. Paul

Publisher page

Abstract

The compressive and tensile properties of polyester polymer and polymer concrete were studied under various curing conditions, temperature, and strain rate. The curing temperature was varied from room temperature to 80°C. The strain rate was varied between 0.01% to 60% strain per minute and the temperature between 22°C and 120°C. The optimum curing condition for polymer and polymer concrete are different. The strength, failure strain, modulus, and stress‐strain relationship of polyester polymer and polymer concrete are influenced by the curing method, testing temperature, and strain rate to varying degrees. The influence of test variables on the mechanical properties of polymer and polymer concrete are quantified. Pretreating the aggregates with a silane coupling agent further enhances the compressive and tensile strength of the polymer concrete. The compressive strength of polymer and polymer concrete are related to their compressive modulus and splitting tensile strength. A constitutive model is used to predict the compressive stress‐strain behavior of polymer and polymer concrete.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Concrete and Cement Materials Research · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Assoc. Prof., Dept. of Civ. Engrg., Univ. of Houston, Houston, TX 77204‐4791

Engr., Texas State Dept. of Hwy. and Public Transp., Houston, TX 77251

References (20)

Show source-provided references
1. Bares R. A. (1978). “Furane resin concrete and its application to large diameter sewer pipes.” SP 58‐4 American Concrete Institute Detroit Mich. 41–74.
2. Chen V. L. Chen E. S. and Vivatrat V. (1985). “Constitutive modeling of sea ice.” Proc. Offshore Tech. Conf. 5057 Society of Petroleum Engineers 343–351.10.4043/5057-MS ↗
3. 10.1177/00219983670010040710.1177/002199836700100407 ↗
4. The status of polymer concrete
5. Field trial of polyester concrete for protection of stilling basin at hydroelectric power station
6. Fontana J. J. and Bartholomew J. (1981). “Use of concrete polymer materials in transportation industry.” ST 69‐2 Applications of Polymer Concrete American Concrete Institute Detroit Mich. 21–43.
7. Fowler D. (1987). “Current status of polymers in concrete.” Proc. 5th Int. Cong. on Polymers in Concrete 3–8.
8. Fowler D. (1990). “Future trends in polymer concrete.” SP 116 American Concrete Institute Detroit Mich. 129–143.
9. “Guide to the use of polymers in concrete.” (1986). ACI J. 83(5) 798–829.10.14359/10674 ↗
10. Haddad M. U. Fowler D. W. and Paul D. R. (1983). “Factors affecting the curing and strength of polymer concrete ACI J. 396–402.
11. Lawrence J. R. (1966). Polyester resin reinhold plastics applications series . Reinhold Publishing Corp. New York N.Y.
12. Studies on cracking and its prevention related to diphenol A polyester mortar and concrete
13. 10.1002/pen.76011020810.1002/pen.760110208 ↗
14. Nielsen L. E. (1974). Mechanical properties of polymers and composites Vol. 2 Marcel Dekker Inc. New York N.Y.
15. Mix proportions and properties of polyester resin concretes
16. 10.1016/0008-8846(87)90105-010.1016/0008-8846(87)90105-0 ↗
17. Bonding agent in polyester polymer concrete
18. 10.1007/BF0248182510.1007/BF02481825 ↗
19. Vipulanandan C. and Paul E. (1988). “Mechanical properties of epoxy and polyester polymers and polymer concrete systems.” Rep. No. UHCE 88‐13 Dept. of Civil Engrg. Univ. of Houston Houston Tex.
20. 10.1002/pen.76030120610.1002/pen.760301206 ↗