journal article·2005-12

New Test for Determination of Masonry Tensile Bond Strength

Fouad M. Khalaf

Publisher page

Abstract

The bond strength between masonry units and mortar has been of considerable interest to researchers for some time. The flexural bond strength of masonry in particular is needed for the design of masonry walls subjected to horizontal forces applied normal to the face of the wall, such as wind forces. Researchers and standards have suggested different kinds of specimens and test procedures to determine the flexural bond strength. These include the test on wallettes (small walls), the bond wrench test, the Brench test, the direct tensile test, and the crossed couplet test. Each of these tests has its own drawbacks and problems. This paper presents a test method to determine the flexural bond strength, ffb , by bending. The test could be used for laboratory research to investigate the many factors affecting bond strength and also for deriving design values for masonry standards. The specimen is constructed from two brick units in a Z-shaped configuration, and three-point loading induces a flexural bond failure parallel to the bed joint. Three different types of clay brick, one calcium silicate brick, and three different types of mortar were used in the experimental program. The results derived show that the proposed new specimen and test procedure are capable of determining the flexural bond strength easily and accurately.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Civil and Structural Engineering Research · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Senior Lecturer, School of the Built Environment, Napier Univ., Edinburgh, EH10 5DT, Scotland, UK.

References (19)

Show source-provided references
1. Bond strength of brickwork from crossed couplet and wallette tests: Some comparative results
2. ASTM · 1989
3. ASTM · 2000
4. ASTM · 2002
5. Australian Standards · 1998
6. British Standards Institution (BSI). (1985). “Specification for clay bricks.” BS 3921 London.
7. British Standards Institution (BSI). (1992). “Use of masonry: Code of practice for use of masonry unreinforced masonry.” BS 5628: Part 1 London.
8. British Standards Institution (BSI). (1998). “Method of testing mortars screeds and plasters: Physical testing.” BS 4551: Part 1 London.
9. Building Research Establishment (BRE). (1991). “Testing bond strength of masonry.” Digest 360 Garston H.K.
10. De Groot C. J. W. P. (1987). “Bond in masonry.” Proc. 5th Int. Conf. on Structural Engineering Analysis and Modeling University of Science and Technology Kumasi Ghana.
11. De Vekey R. C. Edgell G. J. and Dukes R. (1990). “The effect of sand grading on the performance and properties of masonry.” Proc. Brit. Mason. Soc. (UK)ZZZZZZ0950-9615.
12. Grandet B. (1975). “Physico-chemical mechanisms of the bond between clay and cement.” Proc. 3rd Int. Brick and Block Masonry Conf. H. Glitza and K. Göbel eds. Bonn Germany 217–221.
13. Held L. · 1983
14. Hendry A. W. · 2001
15. Jukes P. Bouzeghoub M. C. and Riddington J. R. (1997). “Measurement of tensile strain softening and its influence on bond tensile test results.” Proc. 4th Int. Symp. on Computer Methods in Struct. Masonry G. N. Pande J. Middleton and B. Kralj eds. E & FN Spon London 169–176.
16. Kamf L. (1963). “Factors affecting bond between bricks and mortar.” Proc. Symp. on Masonry Testing ASTM West Conshohocken Pa. 127–141.10.1520/STP39546S ↗
17. Lawrence S. and Cao H. T. (1987). “An experimental study of the interface between brick and mortar.” Proc. 4th North American Masonry Conf. Masonry Society Boulder Colo. 1–14.
18. A masonry joint shear strength test method
19. Sinha B. P. (1967). “Model studies relating to load bearing brickwork.” PhD thesis Univ. of Edinburgh Edinburgh U.K.