Experimental Studies on Concrete Filled Steel Tubes under High Strain Rate Loading

Yan Xiao, Jianhua Shan, Qiu Zheng, Bosheng Chen, Yali Shen

Publisher page

Abstract

A split Hopkinson pressure bar equipment was used to perform high strain rate compressive tests on concrete filled steel tubes (CFT) along with benchmark plain concrete cylinders for comparison. This paper reports the results of dynamic compressive strength, ultimate strain, residual strength and the secant stiffness. The dynamic increase factor (DIF) of CFT strength upon the increase of strain rate was obtained based on the logarithm linear fitting of the test results. The DIF of the CFT specimens can be relatively well estimated with conservatism using the simple superposition of dynamic uniaxial strength of concrete and steel. The confinement stress and the confinement coefficient under high strain rate loading are also discussed based on assumptions similar to those used for the static loading cases.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: High-Velocity Impact and Material Behavior · Structural Response to Dynamic Loads · Transportation Safety and Impact Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Director and Prof., Center for Integrated Protection Research of Engineering Structures (CIPRES), China Education Ministry Key Laboratory of Building Safety and Efficiency, Hunan Univ., Changsha 410082, China; and, Dept. of Civil Engineering, Univ. of Southern California, Los Angeles, CA (corresponding author).

Research Asst., Center for Integrated Protection Research of Engineering Structures (CIPRES), China Education Ministry Key Laboratory of Building Safety and Efficiency, Hunan Univ., Changsha 410082, China.

Research Engineer, Center for Integrated Protection Research of Engineering Structures (CIPRES), China Education Ministry Key Laboratory of Building Safety and Efficiency, Hunan Univ., Changsha 410082, China.

References (17)

Show source-provided references
1. AISC. (2005). “Specification for structural steel buildings.” Chicago.
2. 10.1007/BF0247201610.1007/BF02472016 ↗
3. CEB. (1988). “Concrete structures under impact and impulsive loading.” Bulletin d’Information Synthesis Rep. No . 187 Beijing.
4. Chen Z. Y. · 1986
5. Comite Europeen de Normalisation (CEN). (2003). “Design of composite steel and concrete structures prEN 1994–1-1.” Eurocode 4 Brussels Belgium.
6. Review of static and dynamic properties of steel reinforcing bars
7. The impact behaviour of sleeved concrete cylinders
8. Richart F. E. Brantzaeg A. and Brown R. L. (1929). “The failure of plain and spirally reinforced concrete in compression.” Rep. No . 185 Engrg Experiment Station Univ. of Illinois Urbana Ill.
9. Effects of strain rate on concrete strength
10. Split-Hopkinson pressure-bar tests on concrete and mortar in tension and compression
11. 10.1260/13694330778042972510.1260/136943307780429725 ↗
12. Studies on constitutive law of confined concrete causing strain hardening and slip
13. Tomii M. Yoshimura K. and Morishita Y. (1977). “Experimental studies on concrete filled steel tubular stub columns under concentric loading.” Proc. of the Int. Colloqium on Stability of Structures under Static and Dynamic Loads ASCE New York 718–741.
14. Viest I. M. · 1997
15. Xiao Y. and Mahin S. (2000). “Composite and hybrid structures.” Proc. 6th ASCCS Int. Conf. Univ. of Southern California Los Angeles.
16. 10.3151/crt1990.2.1_110.3151/crt1990.2.1_1 ↗
17. Xiao Y. Zhang W. X. Shan J. H. Chen R. Yi W. J. and Lu F. Y. (2005). “Impact tests of concrete filled tubes and confined concrete steel tubes.” Proc. 6th Asia-Pacific Conf. on Shock and Impact loads on Structures Perth Australia 657–664.