Numerical Study on the Effect of Cracking on Surface Resistivity of Plain and Reinforced Concrete Elements
Source abstract
Abstract
The effect of discrete cracks on the Wenner probe measurements for surface resistivity of plain and reinforced concrete elements is investigated. A numerical modeling approach is utilized to study the effect of a wide range of parameters that are related to discrete cracks (type, depth, width, location, and orientation with respect to the probe), reinforcement (cover thickness, bar spacing, and bar orientation with respect to the crack), and the Wenner probe (electrode spacing). Depending on the type of the crack and its location, the results indicate that measurements might have errors as much as ∼200% higher or ∼50% lower than the actual resistivity of concrete. Rebar mesh reduces measured resistivity and causes additional error in measurements—the denser the reinforcement, the higher the error. Whereas in most scenarios, crack and rebar mesh affect the accuracy of measurements independently, the effect of deep cracks that surpass the depth of rebars is limited by the presence of rebar mesh. A decrease in electrode spacing would reduce the errors associated with rebar mesh while it increases the impact from the crack; therefore, the common perception of using smaller electrode spacing for error minimization is not valid for reinforced concrete elements with cracks.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Geophysical Methods and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate Student, Dept. of Civil and Environmental Engineering, Carleton Univ., Ottawa, ON, Canada K1S 5B6.
President of Giatec Scientific Inc. and Adjunct Professor of Carleton Univ., Ottawa, ON, Canada K1S 5B6.
Associate Professor, Oregon State Univ., School of Civil and Construction Engineering, Corvallis, OR 97331 (corresponding author).
References (30)
Show source-provided references
1. AASHTO. (2011). “Standard method of test for surface resistivity indication of concrete’s ability to resist chloride ion penetration.” TP095-11UL Washington DC.
2. 10.1016/0008-8846(88)90091-910.1016/0008-8846(88)90091-9 ↗
3. On the applicability of the Wenner method for resistivity measurements of concrete
4. ASTM. (2012). “Standard test method for electrical indication of concrete’s ability to resist chloride ion penetration.” C1202-12 West Conshohocken PA.
5. Broomfield J. P. · 2007
6. COMSOL Multiphysics V4.3 [Computer software]. Burlington MA COMSOL.
7. FDOT (Florida Department of Transportation). (2004). “Florida method of test for concrete resistivity as an electrical indicator of its permeability.” FM 5-578 Tallahassee FL.
8. Ghods P. (2010). “Multi-scale investigation of the formation and breakdown of passive films on carbon steel rebar in concrete.” Ph.D. thesis Carleton Univ. Ottawa.10.1149/MA2010-02/13/1204 ↗
9. 10.1016/j.ndteint.2008.03.00110.1016/j.ndteint.2008.03.001 ↗
10. Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique
11. Hamilton H. R. Boyd A. Vivas E. and Bergin M. (2007). “Permeability or concrete: Comparison of conductivity and diffusion methods.” Final Rep. 00026899 Univ. of Florida Gainesville FL.
12. Kessler R. J. Powers R. G. and Paredes M. A. (2005). “Resistivity measurements of water saturated concrete as an indicator of permeability.” Proc. NACE Corrosion 2005 NACE International Houston.
13. LaDOTD (Louisiana Department of Transportation & Development). (2011). “Test method for surface resistivity indication of concrete’s ability to resist chloride ion penetration.” TR 233-11 Baton Rouge LA.
14. 10.1016/S0963-8695(03)00013-610.1016/S0963-8695(03)00013-6 ↗
15. 10.1016/0008-8846(93)90102-F10.1016/0008-8846(93)90102-F ↗
16. 10.1016/j.cemconcomp.2005.03.00810.1016/j.cemconcomp.2005.03.008 ↗
17. 10.1680/iicep.1991.1358310.1680/iicep.1991.13583 ↗
18. 10.1016/S0008-8846(96)00175-510.1016/S0008-8846(96)00175-5 ↗
19. 10.1007/BF0248059910.1007/BF02480599 ↗
20. 10.1016/S0958-9465(01)00074-910.1016/S0958-9465(01)00074-9 ↗
21. 10.1016/j.conbuildmat.2013.06.05310.1016/j.conbuildmat.2013.06.053 ↗
22. Presuel-Moreno F. P. Liu Y. and Paredes M. (2009). “Understanding the effect of rebar presence and/or multilayered concrete resistivity on the apparent surface resistivity measured via the four point wenner method.” Proc. NACE Corrosion 2009 Conf. & Expo. NACE International Houston.10.5006/C2009-09217 ↗
23. Salehi M. (2013). “Numerical investigation of the effects of cracking and embedded reinforcement on surface concrete resistivity measurements using Wenner probe.” M.Sc. thesis Carleton Univ. Ottawa.
24. Numerical investigation of the role of embedded reinforcement mesh on electrical resistivity measurements of concrete using the Wenner probe technique
25. Electrical resistivity measurements for quality control during concrete construction
26. Effect of embedded steel on electrical resistivity measurements on concrete structures
27. 10.1017/CBO978113916793210.1017/CBO9781139167932 ↗
28. Weydert R. and Gehlen C. (1999). “Electrolytic resistivity of cover concrete: Relevance measurement and interpretation.” Proc. Durability of Building Materials and Components NRC Research Press Ottawa 409–419.
29. 10.1016/j.jappgeo.2011.06.00910.1016/j.jappgeo.2011.06.009 ↗
30. 10.1002/nme.162019030710.1002/nme.1620190307 ↗