Chloride-Induced Corrosion in Insufficiently Grouted Posttensioned Concrete Beams

Ha Minh, Hiroshi Mutsuyoshi, Hirotsugu Taniguchi, Kyoji Niitani

Publisher page

Abstract

An experimental program was carried out to clarify the effect of chloride-induced corrosion on posttensioned concrete (PC) beams under different grout conditions using the electrically accelerated corrosion testing method. A series of accelerated corrosion tests were performed to evaluate the influence of insufficient grout condition on corrosion of sheath and prestressing tendon. The radial pressure surrounding the sheath during the corrosion process was also investigated. After a period of accelerated corrosion, the mechanical behavior of the deteriorated PC beams was clarified through loading tests. Prestressing tendon corrosion and its correlation with beam load-carrying capacity was also investigated. The results of the experiments demonstrate a significant influence of corrosion of sheath and prestressing tendon on load-carrying capacity of PC beams. The width of the corrosion crack in PC beams increases with grout filling level inside the sheath. The presence of water inside the sheath leads to increased rates of corrosion of the sheath and prestressing tendon, resulting in an earlier deterioration in the load-carrying capacity of PC beams.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Concrete and Cement Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Assistant Professor, Dept. of Civil and Environmental Engineering, Saitama Univ., 255 Shimo-Okubo, Sakura-ku, Saitama-shi, Saitama-ken 338-8570, Japan.

Professor, Dept. of Civil and Environmental Engineering, Saitama Univ., 255 Shimo-Okubo, Sakura-ku, Saitama-shi, Saitama-ken 338-8570, Japan.

Engineer, Sumitomo Mitsui Construction Co., Ltd., Tokyo, Japan.

Engineering Researcher, Oriental Construction Co., Ltd., Tokyo, Japan.

References (16)

Show source-provided references
1. 10.1016/S0950-0618(01)00009-510.1016/S0950-0618(01)00009-5 ↗
2. 10.1201/978148227189810.1201/9781482271898 ↗
3. 10.4324/978020341460610.4324/9780203414606 ↗
4. 10.1016/S0950-0618(03)00028-X10.1016/S0950-0618(03)00028-X ↗
5. JSA. (1999). “Uncoated stress-relieved steel wires and strands for prestressed concrete.” JIS G3536 Japanese Standards Association Japan.
6. JSCE. (1997). Concrete engineering series 26 Japan Society of Civil Engineers Japan (in Japanese).
7. JSCE. (2002). “Standard specification for concrete structures.” Japan Society of Civil Engineers Japan.
8. 10.1680/macr.1998.50.1.510.1680/macr.1998.50.1.5 ↗
9. Mutsuyoshi H. (2001). “Present situation of durability of posttensioned PC bridges in Japan.” Proc. Workshop on Durability of Posttensioning Tendons fib Belgium 75–88.
10. Mutsuyoshi H. Hamada Y. Igo Y. and Watanabe H. (2004). “Design concepts for durable prestressed concrete structures in Japan.” Proc. Second Workshop on Durability of Post-Tensioning Tendons Swiss Federal Institute of Technology Switzerland 13–22.
11. Public Works Research Institute (PWRI). (2001a). “Evaluation of durability of PC bridges due to chloride attack—Loading test of Kuretsubo Bridge.” Rep. No. 3809 Ministry of Land Infrastructure and Transport Tohoku Regional Development Bureau Japan (in Japanese).
12. Public Works Research Institute (PWRI). (2001b). “Investigation of the life cycle cost of concrete bridges: Damage situation and survey of maintenance expenses.” Ministry of Land Infrastructure and Transport Tohoku Regional Development Bureau Japan (in Japanese).
13. Roberge P. R. · 2000
14. Evaluation of corrosion degree of steel by using corrosion potential
15. Grouts for bonded post-tensioning in corrosive environments
16. Interaction between loading, corrosion, and serviceability of reinforced concrete