journal article·2014-05

Passive Wireless Detection of Corrosive Salts in Concrete Using Wire-Based Triggers

Nicholas Materer, Paul Field, Nicholas Ley, Ahmad Razzaghi Soufiani, Dane Scott, Tyler Ley, Allen Apblett

Publisher page

Abstract

This paper presents an iron wire trigger mechanism that will be used for a new generation of low-cost corrosion sensors that are wireless and do not require batteries or any other external power sources. The corrosion of thin sensor wires, 0.065 to 0.25 mm in diameter, were investigated in sodium chloride solutions and compared with the mass loss from steel coupons under similar conditions. The 0.125- and 0.065-mm wires were embedded in concrete and subjected to accelerated corrosion testing. These wires are suitable for use as triggers for corrosive salts. They behaved similarly to mild reinforcing steel used in concrete structures and their resistance increased significantly at predictable chloride levels. Prototype sensors, constructed using commercial radio frequency identification tags with a section of the antenna replaced by a wire trigger, were embedded in concrete. These results demonstrate the methodology to create successful radio frequency identification based sensors for the egress of corrosive agents, such as chlorides, into concrete.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor, Dept. of Chemistry, Oklahoma State Univ., 107 Physical Science, Stillwater, OK 74078 (corresponding author).

Undergraduate, School of Civil and Environmental Engineering, Oklahoma State Univ., Stillwater, OK 74078.

Lab Manager, School of Civil and Environmental Engineering, Oklahoma State Univ., Stillwater, OK 74078.

Ph.D. Candidate, Dept. of Chemistry, Oklahoma State Univ., Stillwater, OK 74078.

Assistant Professor, Dept. of Chemistry, East Central Univ., Ada, OK 74820.

Associate Professor, School of Civil and Environmental Engineering, Oklahoma State Univ., Stillwater, OK 74078.

Professor, Dept. of Chemistry, Oklahoma State Univ., Stillwater, OK 74078.

References (37)

Show source-provided references
1. Low-cost wireless corrosion and conductivity sensors
2. In situ measurement of conductivity and temperature during concrete curing using passive wireless sensors
3. ASTM. (2011). “Standard test method for determining the apparent chloride diffusion coefficient of cementitious mixtures by bulk diffusion.” ASTM C1556ASTM International West Conshohocken PA.
4. ASTM. (2012). “Standard specification for portland cement.” ASTM C150/C150MASTM International West Conshohocken PA.
5. 10.1016/j.snb.2007.12.03410.1016/j.snb.2007.12.034 ↗
6. 10.1016/S0958-9465(01)00024-510.1016/S0958-9465(01)00024-5 ↗
7. Monitoring of corrosion protection. A concrete-embeddable pH optode
8. Wireless threshold sensors for detecting corrosion in reinforced concrete structures
9. Wireless low-cost corrosion sensors for reinforced concrete structures
10. 10.1021/ac051713910.1021/ac0517139 ↗
11. Development of an integrated sensor to monitor the corrosion process of reinforced concrete structures
12. 10.1063/1.147293610.1063/1.1472936 ↗
13. Fiber optic sensors for an in-situ monitoring of moisture and pH value in reinforced concrete
14. Calibration of optical fiber refractive index sensor with potential for structural corrosion monitoring
15. 10.1002/maco.20039005110.1002/maco.200390051 ↗
16. 10.3390/s803196010.3390/s8031960 ↗
17. 10.4028/www.scientific.net/AMR.97-101.430510.4028/www.scientific.net/AMR.97-101.4305 ↗
18. 10.3390/s10040414510.3390/s100404145 ↗
19. 10.1016/j.cemconcomp.2009.05.00710.1016/j.cemconcomp.2009.05.007 ↗
20. 10.1016/j.cemconcomp.2006.01.00510.1016/j.cemconcomp.2006.01.005 ↗
21. 10.1016/j.electacta.2008.04.07810.1016/j.electacta.2008.04.078 ↗
22. 10.5006/1.329440710.5006/1.3294407 ↗
23. 10.1016/j.cemconres.2003.11.02710.1016/j.cemconres.2003.11.027 ↗
24. 10.4028/www.scientific.net/MSF.587-588.67710.4028/www.scientific.net/MSF.587-588.677 ↗
25. 10.3390/s9110839110.3390/s91108391 ↗
26. A magnetic sensing approach to characterize corrosion in reinforced concrete
27. Corrosion monitoring of reinforcing steel in RC beam by an intelligent corrosion sensor
28. Corrosion monitoring of reinforcing steel in concrete by electrochemical sensors
29. Parameters affecting the measurements of embedded electrical sensors for concrete health monitoring applications
30. Corrosion monitoring systems for design verification—Application at the 36 km Hangzhou Bay Bridge
31. Integrated system for corrosion monitoring of reinforced concrete structures
32. Design and operation of a galvanic sensor for in-service monitoring of the corrosion of steel in concrete
33. Corrosion monitoring of reinforced concrete structures—A review10.1016/S1452-3981(23)17049-0 ↗
34. Sensors for detection of corrosion
35. Rebar corrosion monitoring using embedded minisensors
36. 10.1016/S0008-8846(03)00226-610.1016/S0008-8846(03)00226-6 ↗
37. Yunovic M. Thompson N. G. Vanyos T. B. and Lave L. (2001). “Cost of corrosion: Highway bridges.” 〈http://corrosionda.com/infrastructure/highway/index.htm〉 (Jan. 27 2014).