journal article·2003-10

Strength of Concrete Subjected to Pullout Load

Lionello Bortolotti

Publisher page

Abstract

In the present paper, the theoretical results obtained in a punching theory for concrete slabs are applied to the case of pullout failure. In order to explain the difference between the experimental loads and those predicted by the said theory a process of hardening in tension of concrete is hypothesized as being due to the small size of the reaction ring of the pullout test apparatus. The assumption is made in order to provide reliable expressions to predict the concrete strength from the pullout load. Some equations are provided to predict concrete strength from the pullout load. In order to obtain analogous expressions to confirm the theoretical results, an appropriate statistical-mathematical procedure has been performed on experimental data found in the literature, and some other equivalent equations are derived. Good agreement is found in the comparison between actual and calculated values of the main intervening variables in the problem.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor, Dipartimento di Ingegneria Strutturale, Università di Cagliari, Piazza D’Armi, 09123 Cagliari, Italy.

References (12)

Show source-provided references
1. Punching shear strength in slabs.
2. 10.1007/BF0247256010.1007/BF02472560 ↗
3. Cossu P. and Pozzo E. (1995). “Correlazioni tra forza di estrazione e resistenza a compressione del calcestruzzo nella metodologia pullout al variare del grado di maturazione” (“Correlations between extraction force and concrete compressive strength in the pullout methodology by varying curing entity.”) L’Industria italiana del Cemento 434–439 (in Italian).
4. Lok-strength.
5. Evaluation of the pullout test to determine strength in-situ concrete.
6. Richards O. (1977). “Pullout strength of concrete reproducibility and accuracy of mechanical tests.” ASTM STP Rep. No. 626 American Society for Testing and Materials Philadelphia 32–40.10.1520/STP27081S ↗
7. Rutenbeck T. (1974). “New developments in in-place testing of shotcrete.” Use of Shotcrete for Underground Structural Support Rep. No SP-45 Am. Concrete Inst. Detroit 246–262.
8. Determining concrete strength for control of concrete in structures.
9. Deformation and failure in large-scale pullout tests.
10. Comparison of analytical and experimental internal strain distribution for the pullout test.
11. The effect of geometry and aggregate on the reliability of the pullout test.
12. Statistical methods for in-place predictions by the pullout test.