journal article·2006-08

Polyethylene Duct Cracking on Posttensioning Tendons in Florida Segmented Bridges

Jorge Suarez, Jingyu Zhang, Grace Hsuan, William Hartt

Publisher page

Abstract

During the past 20-plus years, designs based on the post-tension segmental concrete box concept have evolved to become prominent in bridge construction. Critical to the safety and longevity of such structures is the integrity of post-tensioning tendons. However, during the past five years, several Florida bridges have suffered tendon deterioration and failure because of strand corrosion at grout voids in which bleed water had accumulated. In some cases, the high-density polyethylene (HDPE) ducts within which the grouted strands reside had cracked. Although none of the tendon failures to date have been related to the HDPE duct cracking, left unaddressed moisture, chlorides, and oxygen will invariably corrode strands in the long-term. In order to assess the cause(s) and mechanism(s) of HDPE duct cracking, fatigue tests were performed upon duct samples retrieved from representative bridges and the results were compared with those from (1) material property determinations of the corresponding ducts, (2) experiments on simulated tendons that were subjected to thermal cycling, and (3) finite element analyses. Based on the outcomes, a mechanism is proposed for the duct cracking and time-to-cracking projections are made for ducts that are still sound.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate Student, Center for Marine Materials, Florida Atlantic Univ., Sea Tech Campus, 101 North Beach Road, Dania Beach, FL 33004.

Graduate Student, Civil, Architectural, and Environmental Engineering, Drexel Univ., 3141 Chestnut Street, Philadelphia, PA 19104.

Associate Professor, Civil, Architectural, and Environmental Engineering, Drexel Univ., 3141 Chestnut Street, Philadelphia, PA 19104.

Professor and Director, Center for Marine Materials, Florida Atlantic Univ., Sea Tech Campus, 101 North Beach Road, Dania Beach, FL 33004.

References (8)

Show source-provided references
1. Chandrupatla T. · 2002
2. Corven Engineering. (2001). “Mid-Bay Bridge posttensioning evaluation.” Final Rep. Submitted to Florida Department of Transportation District 3 .
3. Corven Engineering. (2002). “New directions for Florida posttensioned bridges.” Final Rep. Submitted to Florida Department of Transportation .
4. Ghorbanpoor A. and Madathanapalli S. C. (1993). “Performance of grouts for posttensioned bridge structures.” Rep. No. FHwA-RD-92-095 Federal Highway Administration Washington D.C.
5. Hartt W. H. Hsuan G. Suarez J. Zhang J. and David F. (2005). “The role of polyethylene duct cracking in failure of posttensioning cables in Florida segmental bridges.” Final Rep. Submitted to Florida Department of Transportation on Project BD220 .
6. Hartt W. H. and Venugopalan S. (2002). “Corrosion evaluation of posttensioned tendons on the Mid-Bay Bridge in Destin Florida.” Final Rep. Submitted to Florida Department of Transportation by Florida Atlantic Univ .
7. Pressure Pipe Institute. (2005). “PPI listing of hydrostatic design basis (HDB) strength design basis (SDB) pressure design basis (PDB) and minimum required strength (MRS) ratings for thermoplastic piping materials or pipe.” Publication TR-4/2005 Washington D.C.
8. Tabatabai H. Ciolko A. T. and Dickson T. J. (2000). “Implications of test results from full-scale fatigue tests of stay cables composed of seven-wire prestressing strand.” Proc. 4th Int. Bridge Engineering Conf. Vol. 1 Transportation Research Board National Research Council Washington D.C.