High-Early-Strength, High-Resistivity Concrete for Direct-Current Light Rail
Source abstract
Abstract
Stray current from direct-current light rail systems can corrode underground metal pipes, potentially causing significant damage to utility lines. To address this problem, Seattle Public Utilities has adopted two preventative measures: use of a dielectric rubber boot and a high-resistivity concrete rail bed. In this work, a constructible, high-resistivity concrete mix was developed using supplementary cementitious materials. The concrete is highly workable, can be placed year-round, and has a high early strength to minimize road closures. In addition, the resistivity is 100 times greater than standard concrete. Based on these data, concrete mixes using Type III portland cement with ternary combinations of silica fume, slag, and Class F fly ash were evaluated. Fresh-state properties, including slump, air content, and density, were determined. Samples were subjected to curing conditions similar to the Seattle area. The compressive strength and resistivity of the mixes were monitored over time. In addition, the effect of temperature on the setting behavior was evaluated. The results indicate that a constructible, highly resistive concrete mix design can be achieved.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Smart Materials for Construction · Concrete Corrosion and Durability · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Project Engineer, Tinnea and Associates, 2018 East Union St., Seattle, WA 98122.
President, Tinnea and Associates, 2018 East Union St., Seattle, WA 98122.
Professor and Chair, Dept. of Civil and Environmental Engineering, Seattle Univ., 901 12th Ave., WA 98122 (corresponding author).
References (28)
Show source-provided references
1. ASTM. (2003). “Standard test method for slump of hydraulic concrete.” ASTM C143-03 West Conshohocken PA.
2. ASTM. (2008). “Standard specification for concrete aggregates.” ASTM C33 West Conshohocken PA.
3. ASTM. (2009a). “Standard specification for air-entraining admixtures for concrete.” ASTM C260 West Conshohocken PA.
4. ASTM. (2009b). “Standard specification for chemical admixtures for concrete.” ASTM C494 West Conshohocken PA.
5. ASTM. (2009c). “Standard specification for coal fly ash and raw or calcined natural pozzolan for use in concrete.” ASTM C618 West Conshohocken PA.
6. ASTM. (2009d). “Standard specification for portland cement.” ASTM C150 West Conshohocken PA.
7. ASTM. (2009e). “Standard specification for silica fume used in cementitious materials.” ASTM C1240 West Conshohocken PA.
8. ASTM. (2009f). “Standard test method for density (unit weight) yield and air content (gravimetric) of concrete.” ASTM C138 West Conshohocken PA.
9. Bellomio S. Fanoni M. Johnson D. and Swanson J. (2009). “High early strength high resistivity concrete.” Seattle Univ. Seattle.
10. 10.1201/978148226549110.1201/9781482265491 ↗
11. Current practice sheet no. 128: Measuring concrete resistivity to assess corrosion rates
12. Estimating long-term concrete electrical resistivity
13. Estimating long-term concrete electrical resistivity
14. Chaker V. (1981). “STP741: Simplified method for the electrical soil resistivity measurement.” ASTM West Conshohocken PA.
15. 10.1016/j.conbuildmat.2014.08.00910.1016/j.conbuildmat.2014.08.009 ↗
16. Florida Department of Transportation. (2004). “Florida method of test for concrete resistivity as an electrical indicator of its permeability: FM 5-578.” Tallahassee FL.
17. 10.1016/j.conbuildmat.2009.06.00810.1016/j.conbuildmat.2009.06.008 ↗
18. Kessler R. J. Powers R. G. and Paredes M. A. (2005). “Resistivity measurements of water saturated concrete as an indicator of permeability.” NACE International Houston.
19. Alkali-silica reaction mitigation: State of the art and recommendations
20. Global concrete industry sustainability: Tools for moving forward to cut carbon emissions
21. Mindess S. · 2003
22. 10.1016/S0008-8846(96)00175-510.1016/S0008-8846(96)00175-5 ↗
23. Performance of supplementary cementitious materials in concrete resistivity and corrosion monitoring evaluations
24. 10.3141/2342-1110.3141/2342-11 ↗
25. Electrical properties of cementitious systems: Formation factor determination and the influence of conditioning procedures10.1520/ACEM20150035 ↗
26. Tinnea R. et al. (2009). “Testing of high-resistivity concrete.” NACE Int. Conf. NACE International Houston.10.5006/C2009-09216 ↗
27. Early strength gain of rapid highway repairs
28. 10.1016/S0008-8846(00)00374-410.1016/S0008-8846(00)00374-4 ↗