Influence of Electrochemical Chloride Extraction on the Performance of Prestressed Concrete under Dynamic Loading Conditions

Michael Siegwart

Publisher page

Abstract

One of the major causes of corrosion of reinforced concrete structures worldwide is chloride. With progressing corrosion, the integrity of the structure is at stake and repair measures are necessary. In recent years electrochemical repair methods such as chloride extraction or cathodic protection have become increasingly popular. Chloride extraction is less expensive as compared to traditional patch repair methods due to its short duration. It is accepted for application on ordinary concrete structures with mild steel reinforcement. Its application on prestressed concrete, however, has been ruled out because of the danger of hydrogen embrittlement. Contradicting results of research on the subject have suggested that chloride extraction might be a feasible repair option for prestressed concrete structures, thus leading to major cost savings for bridge owners. This study investigated the feasibility of chloride extraction on prestressed concrete structures. A distinction was made between hydrogen embrittlement, which temporarily reduces the ductility of steel, and hydrogen-induced stress corrosion cracking, which leads to sudden and unexpected collapse of the structure. The most commonly accepted test methods for hydrogen embrittlement are constant extension rate tests, but they give little indication of the performance of the prestressed tendons under serviceability conditions. In this study, along with constant extension rate tests, 22 prestressed concrete specimens were also tested using a fatigue test program. The fractured surfaces were carefully investigated to identify signs of hydrogen embrittlement and to rule out any other causes of failure. The results of the study suggest that chloride extraction temporarily reduces the fatigue life of prestressed steel. Although hydrogen-induced stress corrosion cracking was not observed for the type of steel investigated in the main study, it occurred for a different type of steel. Statistic analysis of the fatigue tests also suggested the possibility of hydrogen-induced stress corrosion cracking for the investigated steel; therefore, chloride extraction should not be applied to prestressed concrete structures.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Basler & Hofmann Ingenieure und Planer AG, Forchstrasse 395, 8032 Zürich, Switzerland. E-mail: michael.siegwart@bhz.ch

References (38)

Show source-provided references
1. Ashida M. and Ishibashi K. (1993). “Influence of direct current on PC bars prestressed in concrete.” Proc. 47th Annual Meeting Japan Construction Association Tokyo 518–523.
2. Ball C. · 2000
3. Bennett J. Turk T. and Savinell R. (1994). “Mathematical modeling of the effects of current flow through concrete.” Proc. Corrosion 94 NACE International Houston Paper 285.
4. Bockris J. O’M. · 199810.1007/b114546 ↗
5. Embrittlement due to hydrogen: Understanding the causes permits to take countermeasures
6. British Standards Institution (BSI). (1980). “Specification for high tensile steel wire and strand for the prestressing of concrete.” BS 5896 London.
7. British Standards Institution (BSI). (1990). “Stress corrosion testing. Part 7: Method for slow strain rate testing.” BS 6980 Part 7 London.
8. Carter A. D. S. · 1982
9. 10.1016/0010-938X(80)90089-X10.1016/0010-938X(80)90089-X ↗
10. Cottis R. A. · 1994
11. Cottrell A. · 1971
12. Cromie J. A. (1998). “Modeling the electrochemical rehabilitation of chloride contaminated reinforced concrete structures.” Ph.D. thesis Univ. of Ulster Ulster U.K.
13. Elices M. Sánchez-Gálvez V. Bernstein I. M. and Parkins R. N. (1982). “Summary of a meeting on stress corrosion cracking and hydrogen embrittlement of steels for prestressing concrete.” Proc. 1st Int. Conf. on Current Solutions to Hydrogen Problems in Steels American Society for Metals Metal Park Ohio 304–307.
14. Funahashi M. and Young W. T. (1996). “Cathodic protection of prestressed bridge members—Full-scale testing.” Transportation Research Record. 1561 Transportation Research Board Washington D.C. 13–25.10.1177/0361198196156100103 ↗
15. 10.1007/978-1-4899-7232-3_2510.1007/978-1-4899-7232-3_25 ↗
16. 10.4028/www.scientific.net/MSF.289-292.2910.4028/www.scientific.net/MSF.289-292.29 ↗
17. 10.1002/best.19950019010.1002/best.199500190 ↗
18. The risk of hydrogen embrittlement in high strength prestressing steels under cathodic protection
19. Lillard R. S. · 1996 · 125
20. 10.1139/l99-04310.1139/l99-043 ↗
21. 10.1016/S0010-938X(97)00099-110.1016/S0010-938X(97)00099-1 ↗
22. 10.1179/00070598179827490410.1179/000705981798274904 ↗
23. 10.1179/00070598179827475110.1179/000705981798274751 ↗
24. Wasserestoffinduzierte Spannungsrisskorrosion in Vergüteten Spannstähen
25. Mietz J. · 1998
26. Odden L. and Miller J. B. (1994). “Norsk Hydro Karmøy—Realkalisation of alumina silo no. 5.” Norwegian Concrete Technologies Rep. Norwegian Concrete Technologies Oslo Norway.
27. Parkins R. N. · 1994
28. 10.1016/0010-938X(82)90017-810.1016/0010-938X(82)90017-8 ↗
29. Roberge P. · 2000
30. 10.1016/0008-4433(94)00018-F10.1016/0008-4433(94)00018-F ↗
31. Siegwart M. · 2002
32. Tobias P. · 1999
33. Townsend H. E. · 1972 · 39
34. 10.1179/00070597179832404410.1179/000705971798324044 ↗
35. 10.1179/02670839679016587610.1179/026708396790165876 ↗
36. 1997
37. Wagner J. Young W. and Scheirer S. (1991). “Cathodic protection of prestressed members: An update.” Transportation Research Record. 1304 Transportation Research Board Washington D.C. 144–152.
38. Wagner J. Young W. and Scheirer S. (1993). “Cathodic protection developments for prestressed concrete components.” FHWA-RD-92-056 U.S. Dept. of Transportation Washington D.C.