journal article·2024-10

Waste Paint as Admixture for Glass Fiber–Reinforced Concrete Building Façades

Dushan Fernando, Pathmanathan Rajeev, Akilesh Ramesh, Jay Sanjayan

Publisher page

Abstract

Building façade elements should have aesthetically pleasing geometrical shapes made up of sustainable materials with energy-efficient designs. The low mass-to-high strength ratio of glass fiber–reinforced concrete (GFRC) has the potential to be adopted as a façade material and has been used in the manufacturing of façade elements. The workability of GFRC mixes is comparatively low; therefore, commercial polymer admixtures are used to improve it. The application of commercial polymers may reduce the fire resistance of GFRC mixes due to their easy combustibility. This study investigated the possible application of waste paint to completely replace commercial polymer admixtures in GFRC. It explored the optimum dosage of waste paint to achieve the required strength of a GFRC mix to be used as a façade material. First, characterization of the waste paint was carried out using its rheological properties and solid content, which were compared with commercially available polymer and paint. Subsequently, the effect of different dosages of waste paint (i.e., 0.5%, 1%, and 2% by mass) on the workability and mechanical properties of GFRC mixes (e.g., compressive and flexural strength) was evaluated. Water absorption and porosity were also evaluated. Finally, the combustibility of GFRC mixes with waste paint was evaluated to qualitatively assess fire performance when compared with polymer GFRC mixes. The experimental results demonstrated that the addition of waste paint to the GFRC mixes improved workability. Furthermore, the mixes with a waste paint dosage of less than 1% showed no significant variation in compressive strength compared with the commercial polymer mix. However, the mix with 1% waste paint enhanced flexural strength by 34% whereas a further increase in waste paint content was observed to reduce flexural capacity due to an increase in porosity. Finally, the fire performance of the mixes showed that waste paint is a noncombustible material and can be used as a potential substitute for polymer admixtures in façade applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Innovations in Concrete and Construction Materials · Polymer Nanocomposites and Properties · Natural Fiber Reinforced Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Master’s Student, Centre for Sustainable Infrastructure and Digital Construction, Swinburne Univ. of Technology, Melbourne, VIC 3122, Australia.

Professor, Centre for Sustainable Infrastructure and Digital Construction, Swinburne Univ. of Technology, Melbourne, VIC 3122, Australia (corresponding author). ORCID: .

Ph.D. Student, Centre for Sustainable Infrastructure and Digital Construction, Swinburne Univ. of Technology, Melbourne, VIC 3122, Australia. ORCID: .

Professor, Centre for Sustainable Infrastructure and Digital Construction, Swinburne Univ. of Technology, Melbourne, VIC 3122, Australia.

References (42)

Show source-provided references
1. 10.1016/j.rinma.2019.10000410.1016/j.rinma.2019.100004 ↗
2. 10.1016/j.cemconcomp.2012.02.00110.1016/j.cemconcomp.2012.02.001 ↗
3. 10.1016/j.cemconcomp.2013.10.01710.1016/j.cemconcomp.2013.10.017 ↗
4. Amed, B., and N. Kabay. 2019. “Glass fibre reinforced precast concrete containing high content pozzolanic materials.” Sigma J. Eng. Nat. Sci. 37 (2): 675–686.
5. 10.1016/j.cemconcomp.2022.10485410.1016/j.cemconcomp.2022.104854 ↗
6. 10.1016/j.wasman.2010.09.01110.1016/j.wasman.2010.09.011 ↗
7. Bonner, M., and G. Rein. 2018. “Flammability and multi-objective performance of building façades: Towards optimum design.” Int. J. High-Rise Build. 7 (4): 363–374.
8. 10.1016/j.apenergy.2020.11479710.1016/j.apenergy.2020.114797 ↗
9. 10.1016/j.jclepro.2006.06.02110.1016/j.jclepro.2006.06.021 ↗
10. 10.1016/j.compositesa.2009.12.00210.1016/j.compositesa.2009.12.002 ↗
11. 10.1016/j.engfailanal.2011.01.00410.1016/j.engfailanal.2011.01.004 ↗
12. 10.1617/s11527-012-9902-610.1617/s11527-012-9902-6 ↗
13. 10.1145/3414685.341784310.1145/3414685.3417843 ↗
14. GFRC Association 2006. Specification for the manufacture, curing and testing of GRC products. Blackwater, UK: GFRC Association.
15. Godfrey C. 2008. “The reuse of latex paint as a polymeric admixture in concrete.” MEng Dissertation Dept. of Civil Engineering Univ. of Bath.
16. Greiner, T., V. Velva, and A. Phipps. 2004. A background report for the national dialogue on paint product stewardship, 12–13. Lowell, MA: Product Stewardship Institute, Univ. of Massachusetts/Lowell.
17. 10.1016/j.jobe.2015.09.00610.1016/j.jobe.2015.09.006 ↗
18. Herzog, T., R. Krippner, and W. Lang. 2012. Facade construction manual. Washington, DC: Walter de Gruyter.
19. 10.1016/j.apenergy.2015.08.07410.1016/j.apenergy.2015.08.074 ↗
20. 10.1016/j.proeng.2011.07.28110.1016/j.proeng.2011.07.281 ↗
21. Kirkpatrick D. D. Hakim and J. Glanz. 2017. “Why Grenfell Tower burned: Regulators put cost before safety.” The New York Times June 24 2017.
22. 10.1007/978-981-15-1052-6_210.1007/978-981-15-1052-6_2 ↗
23. Liu Z. Q. Cui and Q. Li. 2015. “Properties of GRC modified by emulsion.” In Proc. GRCA 2015 Congress 19–21. Hampton UK: International Glassfibre Reinforced Concrete Association.
24. 10.1016/0010-4361(87)90009-710.1016/0010-4361(87)90009-7 ↗
25. Mohammed, A., M. Nehdi, and A. Adawi. 2008. “Recycling waste latex paint in concrete with added value.” ACI Mater. J. 105 (4): 367. https://doi.org/10.14359/19898.
26. 10.1002/fam.212810.1002/fam.2128 ↗
27. 10.1016/S0266-3538(00)00204-910.1016/S0266-3538(00)00204-9 ↗
28. 10.1016/j.cemconcomp.2022.10445110.1016/j.cemconcomp.2022.104451 ↗
29. Mwasha, A., C. Mwasha, and A. Archers. 2009. Preservation of historic building frontages: Problems and general recommendations for Caribbean environment. Washington, DC: American Society for Engineering Education.
30. 10.1016/S0008-8846(02)01084-010.1016/S0008-8846(02)01084-0 ↗
31. 10.56748/ejse.1621210.56748/ejse.16212 ↗
32. 10.1016/j.conbuildmat.2016.10.10010.1016/j.conbuildmat.2016.10.100 ↗
33. NPCA (National Precast Concrete Association). 2006. Design, manufacture and installation of glass reinforced concrete (GRC). Glenelg, Australia: NPCA.
34. 10.1016/j.progpolymsci.2008.07.00810.1016/j.progpolymsci.2008.07.008 ↗
35. 10.1016/j.cemconcomp.2023.10504710.1016/j.cemconcomp.2023.105047 ↗
36. 10.1016/j.jobe.2024.10887310.1016/j.jobe.2024.108873 ↗
37. Remmler, T. 2017. Optimizing rheology for paint and coating applications. Malvern, Worcestershire: Malvern Instruments.
38. Schreck J. G. 2016. “How a common building material turned a Dubai hotel fire into an inferno.” Accessed October 9 2023. https://www.thestar.com/business/2016/01/19/how-a-common-building-material-turned-a-dubai-hotel-fire-into-an-inferno.html.
39. Soroushian, P., A. Tlili, M. Yohena, and B. L. Tilsen. 1993. “Durability characteristics of polymer-modified glass fiber reinforced concrete.” Mater. J. 90 (1): 40–49. https://doi.org/10.14359/4037.
40. 10.1016/0010-4361(85)90656-110.1016/0010-4361(85)90656-1 ↗
41. Whittingstall P. 2011. “Paint evaluation using rheology.” TA Instruments Publication Rh059. Accessed July 28 2023. http://www.tainstruments.com/library_download.aspx.
42. 10.1002/fam.297310.1002/fam.2973 ↗