Chemical Effects on Flexible‐Membrane Liner Seams
Source abstract
Abstract
Twelve‐month exposure data were completed on 37 different seamed‐membrane materials. Seaming methods described and evaluated include adhesive bonding, bodied‐solvent bonding, solvent adhesive, and thermal methods resulting in polymer melting. The seamed materials were exposed in 10% phenol (organic acid), 10% HC1 (inorganic acid), 10% NaOH (inorganic base), 10% MEK (ketone), 5% furfural (aldehyde), and 100% methylene chloride (halogenated hydrocarbon). Assessment by shear and peel testing showed that materials not having chemical resistance had significant property reduction after only three months of exposure. Thermally produced seams had better resistance than did those based on solvent or adhesive bonding. For reinforced materials, the predominant failures in shear were associated with scrim failure and pull‐out, and failures in peel were evenly distributed between ply separation scrim breakage or adhesive‐bond‐system failure‐scrim delamination and pull‐out. For nonreinforced materials, failures in shear were mostly in parent material, and failures in peel occurred either in parent material or between the adhesive and the liner surface.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Chief Engr., Hauser Laboratories, Inc., 5680 Central Ave., Boulder, CO 80301
Chemical Engr., Hauser Laboratories, Inc., Boulder, CO
Res. Dir., Hauser Laboratories, Inc., Boulder, CO
References (5)
Show source-provided references
1. Haxo H. E. Jr. et al. (1982). Liner materials exposed to municipal solid waste leachate . National Technical Information Service Springfield Va.
2. Haxo H. E. Jr. et al. (1984). “Liner materials exposed to hazardous and toxic waste.” EPA/600/2–84/169 . U.S. Environmental Protection Agency Cincinnati Ohio.
3. Mitchell D. H. and Spanner G. E. (1984). “Field performance assessment of synthetic liners for uranium tailings pond.” Status Report PNL‐5005 . Pacific Northwest Laboratory Battelle Memorial Institute.10.2172/6839611 ↗
4. Morrison W. R. and Parkhill L. D. (1987). Evaluation of flexible membrane liner seams after chemical exposure and simulated weathering . Bureau of Reclamation Engrg. and Res. Ctr. Denver Colo.
5. Nelson W. A. Haxo H. E. Jr. and McGlew P. (1985). “Recovery and testing of a synthetic liner from a waste lagoon after long term exposure.” Proc. 11th Annual Res. Symp. EPA/600/9–85/013 U.S. Environmental Protection Agency Cincinnati Ohio.