This paper presents recommendations on the repair of cracked columns based upon the writers’ experiences, found from repair of cracked column flanges following the 1994 Northridge Earthquake. This paper also describes tests carried out using volumetric weld repairs on thick plates to evaluate acceptable procedures for the repair of column flanges with partial cracks damaged from earthquakes. Cracks were often found in the bottom flange of welded joints. In some cases, cracks propagated into column flanges, and in a few cases into their webs. Repairs of cracked welded joints are discussed at some length in other documents and thus are not part of the scope of this paper. One method for the repair of cracked columns involves replacement of the column flange with a new plate. Another method of repair involves the use of volumetric welds to replace the cracked portion of the column flange. This paper includes a description of the development of procedures and limited testing to assess the adequacy of the volumetric repair method of partial column cracks.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

President, Brandow & Johnston Associates, 1660 W. 3rd St., Los Angeles, CA 90017.

Associate, Brandow & Johnston Associates, 1660 W. 3rd St., Los Angeles, CA 90017.

References (5)

Show source-provided references
1. American Welding Society (AWS). (2000). “Structural welding code-steel.” ANSI/AWS D1.1
2. Dong P. and Zhang J. (1998). “Residual stresses in welded moment frames and implications on structural performance.” Proc. on Welded Construction in Seismic Areas American Welding Society Miami 57–73.
3. Federal Emergency Management Agency (FEMA). (1995). “Interim guidelines: evaluation repair modification and design of welded steel moment frame structures.” FEMA 267 Washington D.C.
4. Maranian P. J. (1997). “Vulnerability of existing steel framed buildings following the 1994 Northridge (California USA) earthquake: considerations for their repair and strengthening.” The Structural Engineer 75(10).