An amperometric biosensor for L-glutamate determination prepared from L-glutamate oxidase immobilized in polypyrrole-polyvinylsulphonate film
Source abstract
Abstract
In this paper, a novel amperometric L-glutamate (Glu) biosensor with immobilization of L-glutamate oxidase (L-GlOx) on polypyrrole-polyvinylsulphonate (PPy-PVS) film has been successfully developed. L-GlOx enzyme was immobilized on PPy-PVS film by cross-linking with glutaraldehyde (GA) and bovine serum albumin (BSA). Determination of Glu was carried out by oxidation of enzymatically produced H2O2 at 0.3 V versus Ag/AgCl. The optimum pH and temperature parameters were found to be 9.0 and 55 °C, respectively. There were three linear parts in the regions between 1.0 × 10(-9) and 1.0 × 10(-8) M (R(2) = 0.847), 5.0 × 10(-8) and 5.0 × 10(-7) M (R(2) = 0.997), 5.0 × 10(-7) and 5.0 × 10(-5) M (R(2) = 0.994). Storage stability, operation stability of the enzyme electrode were also studied.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Neuroscience and Neuropharmacology Research · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Chemistry, Institute of Sciences, Gazi University
Department of Chemistry, Faculty of Science and Art, Bozok University
References (24)
Show source-provided references
1. 10.1016/j.bios.2005.07.01210.1016/j.bios.2005.07.012 ↗
2. Arslan H, Arslan F. 2011. Preparation of a polypyrrole- polyvinylsulphonate composite film biosensor for determination of phenol based on entrapment of polyphenol oxidase. Artif Cells Nanomed Biotechnol. 39:341–345.
3. 10.1016/j.bios.2005.09.01110.1016/j.bios.2005.09.011 ↗
4. 10.1016/j.snb.2006.05.02210.1016/j.snb.2006.05.022 ↗
5. 10.1016/S0003-2670(99)00533-410.1016/S0003-2670(99)00533-4 ↗
6. 10.1016/S0013-4686(00)00658-710.1016/S0013-4686(00)00658-7 ↗
7. 10.1016/S0003-2670(00)80201-910.1016/S0003-2670(00)80201-9 ↗
8. 10.1080/1073119060068411610.1080/10731190600684116 ↗
9. Çolak Ö, Yaşar A, Çete S, Arslan F. 2012. Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde. Artif Cells Nanomed Biotechnol. 40:354–361.
10. 10.3109/10731199.2011.64641010.3109/10731199.2011.646410 ↗
11. Ghobadi S, Csöregi E, Marko-Varga G, Gorton L. 1996. Bienzyme carbon paste electrodes for L-glutamate determination. Curr Sep. 14:94–102.
12. 10.1016/S0013-4686(00)00644-710.1016/S0013-4686(00)00644-7 ↗
13. 10.1016/S0003-2670(98)00202-510.1016/S0003-2670(98)00202-5 ↗
14. 10.1021/ac990801o10.1021/ac990801o ↗
15. 10.1016/j.bios.2006.11.00310.1016/j.bios.2006.11.003 ↗
16. Nelson DL, Cox MM. 2000. Lehninger Principles of Biochemistry. New York: Worth Publishers.
17. 10.3109/10731199.2011.64641110.3109/10731199.2011.646411 ↗
18. 10.1016/0039-9140(95)01854-910.1016/0039-9140(95)01854-9 ↗
19. 10.1016/j.ab.2003.08.01810.1016/j.ab.2003.08.018 ↗
20. 10.1016/0021-9673(95)01237-010.1016/0021-9673(95)01237-0 ↗
21. 10.1016/S0009-9120(98)00003-410.1016/S0009-9120(98)00003-4 ↗
22. 10.1006/abio.1998.265010.1006/abio.1998.2650 ↗
23. 10.1016/S0003-2670(96)00492-810.1016/S0003-2670(96)00492-8 ↗
24. 10.1016/j.bios.2006.08.03810.1016/j.bios.2006.08.038 ↗