journal article·2023-09Open access

Electrochemical behavior of additively manufactured patterned titanium alloys under simulated normal, inflammatory, and severe inflammatory conditions

Aydin Bordbar-Khiabani, Michael Gasik

Abstract

The electrochemical behavior of a biomaterial surface in local conditions is a significant factor affecting the success of the implant placement. This is of a particular importance of metallic biomaterials which can undergo oxidation, corrosion and subsequent degradation. This study reports new data on the electrochemical behavior of additively manufactured (AM) patterned titanium alloys, analyzed after 1 and 12 h immersion in three different media mimicking normal, inflammatory and severe inflammatory conditions. Polarization study showed that corrosion resistance increases with increasing immersion time in all cases. It was found that in inflammatory condition a destructive effect on the passive layer's resistance was triggered by H2O2 whereas in severe inflammatory condition, albumin, lactate, and H2O2 all have a synergistic effect towards decreasing the corrosion resistance of patterned titanium layers. Electrochemical impedance data suggests that in the severe inflammatory condition the charged albumins are attracting to the localized pitting areas, changing diffusion transport of corrosive species at the interface of the metal/passive layer. The electrochemical tests also proven that laser-assisted patterned titanium alloys surfaces have an improved corrosion resistance in simulated solutions compared to untreated titanium of the same composition. It is suggested that new surface topography and wettability are also positive factors contributing to this improved corrosion performance in patterned specimens.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (83)

Show source-provided references
1. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants—is one truly better than the other?10.1016/j.msec.2016.01.032 ↗
2. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
3. Biocompatibility of titanium from the viewpoint of its surface10.1080/14686996.2022.2106156 ↗
4. A review on biomedical titanium alloys: recent progress and prospect10.1002/adem.201801215 ↗
5. Titanium implants with modified surfaces: meta-analysis of in vivo osteointegration10.1016/j.msec.2014.12.074 ↗
6. Understanding biomaterial-tissue interface quality: combined in vitro evaluation10.1080/14686996.2017.1348872 ↗
7. Titanium based bone implants production using laser powder bed fusion technology10.1016/j.jmrt.2022.01.087 ↗
8. Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting10.1016/j.jmbbm.2011.05.010 ↗
9. Influences of surface topography of porous titanium scaffolds manufactured by powder bed fusion on osteogenesis10.1016/j.jmrt.2023.01.153 ↗
10. Antibiofilm effects of titanium surfaces modified by laser texturing and hot-pressing sintering with silver10.1002/jbm.b.34817 ↗
11. Friction stability and cellular behaviors on laser textured Ti–6Al–4V alloy implants with bioinspired micro-overlapping structures10.1016/j.jmbbm.2020.103823 ↗
12. Dual modulation of crystallinity and macro-/microstructures of 3D printed porous titanium implants to enhance stability and osseointegration10.1039/C9TB00093C ↗
13. Novel laser surface texturing for improved primary stability of titanium implants10.1016/j.jmbbm.2019.04.052 ↗
14. Pulsed electromagnetic fields promote osteogenesis and osseointegration of porous titanium implants in bone defect repair through a Wnt/β-catenin signaling-associated mechanism10.1038/srep32045 ↗
15. Metallurgy principles applied to powder bed fusion 3D printing/additive manufacturing of personalized and optimized metal and alloy biomedical implants: an overview10.1016/j.jmrt.2019.12.015 ↗
16. Strategies for creating living, additively manufactured, open-cellular metal and alloy implants by promoting osseointegration, osteoinduction and vascularization: an overview10.1016/j.jmst.2018.09.003 ↗
17. A study on the production of thin-walled Ti6Al4V parts by selective laser melting10.1016/j.jmapro.2018.12.036 ↗
18. Multi-functional Ti6Al4V-CoCrMo implants fabricated by multi-material laser powder bed fusion technology: a disruptive material's design and manufacturing philosophy10.1016/j.jmbbm.2022.105583 ↗
19. Additive manufacturing of a porous titanium layer structure Ti on a Co-Cr alloy for manufacturing cementless implants10.1016/j.jmrt.2020.11.080 ↗
20. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: a review10.1016/j.biomaterials.2016.01.012 ↗
21. Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits10.1002/jbm.1069 ↗
22. Influence of the structural orientation on the mechanical properties of selective laser melted Ti6Al4V open-porous scaffolds10.1016/j.matdes.2016.01.095 ↗
23. Bone biomaterials and interactions with stem cells10.1038/boneres.2017.59 ↗
24. Journey into bone models: a review10.3390/genes9050247 ↗
25. Effect of pore geometry on the fatigue properties and cell affinity of porous titanium scaffolds fabricated by selective laser melting10.1016/j.jmbbm.2018.08.048 ↗
26. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
27. Corrosion of metallic biomaterials: a review10.3390/ma12030407 ↗
28. Surface modification methods for titanium and its alloys and their corrosion behavior in biological environment: a review10.1007/s40735-019-0229-5 ↗
29. Research progress on the corrosion behavior of titanium alloys10.1515/corrrev-2022-0031 ↗
30. Design, clinical translation and immunological response of biomaterials in regenerative medicine10.1038/natrevmats.2016.40 ↗
31. Immune responses to implants–a review of the implications for the design of immunomodulatory biomaterials10.1016/j.biomaterials.2011.05.078 ↗
32. Macrophage-assisted dissolution of gold nanoparticles10.1021/acsabm.8b00537 ↗
33. Foreign body reaction to biomaterials10.1016/j.smim.2007.11.004 ↗
34. Study of the corrosion properties of powder rolled Ti–6Al–4V alloy applied in the biomedical implants10.1016/j.jmrt.2022.04.004 ↗
35. Electrochemical and biological characterization of Ti–Nb–Zr–Si alloy for orthopedic applications10.1038/s41598-023-29553-5 ↗
36. Corrosion behavior of titanium modified by direct laser interference lithography10.1016/j.surfcoat.2021.127219 ↗
37. Laser induced periodic surface structure on titanium alloy and its effect on microstructure refinement and corrosion behavior10.1016/j.jallcom.2022.168188 ↗
38. Microstructure and corrosion behavior of laser induced periodic patterned titanium based alloy10.1016/j.optlastec.2019.03.017 ↗
39. Microstructure and corrosion resistance of novel β-type titanium alloys manufactured by selective laser melting10.1016/j.jmrt.2022.07.021 ↗
40. Designing the microstructural constituents of an additively manufactured near β Ti alloy for an enhanced mechanical and corrosion response10.1016/j.matdes.2022.110618 ↗
41. A novel method for production of foamy core@compact shell Ti6Al4V bone-like composite10.1016/j.jallcom.2015.09.248 ↗
42. Micro-CT-based improvement of geometrical and mechanical controllability of selective laser melted Ti6Al4V porous structures10.1016/j.msea.2011.06.045 ↗
43. Evaluations of cellular lattice structures manufactured using selective laser melting10.1016/j.ijmachtools.2012.06.002 ↗
44. Heat treatment of Ti6Al4V produced by selective laser melting: microstructure and mechanical properties10.1016/j.jallcom.2012.07.022 ↗
45. Microstructure, microhardness and corrosion resistance of remelted TiG2 and Ti6Al4V by a high power diode laser10.1016/j.corsci.2011.11.006 ↗
46. Surface characterization of titanium-based substrates for orthopaedic applications10.1016/j.matchar.2021.111161 ↗
47. The effect of zinc oxide coating morphology on corrosion performance of Ti-6Al-4 V alloys10.1016/j.jallcom.2021.160771 ↗
48. Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting10.1088/1758-5090/8/4/045014 ↗
49. Additive texturing of metallic implant surfaces for improved wetting and biotribological performance10.1016/j.jmrt.2022.08.029 ↗
50. Comparison of the structural properties, surface wettability and corrosion resistance of TiO2 nanotubes fabricated on Cp-Ti, Ti6Al4V and Ti45Nb10.1016/j.mtcomm.2022.104396 ↗
51. The Comparison of wear performances of CP-Ti, Ti6Al4V, Ti45Nb alloys oxidized by anodic oxidation under ambient air and vacuum conditions10.1016/j.mtcomm.2023.105466 ↗
52. Corrosion behavior of Ti-29Nb-13Ta-4.6Zr and commercially pure Ti under simulated inflammatory conditions–comparative effect of grain refinement and non-toxic β phase stabilizers10.1016/j.electacta.2019.04.138 ↗
53. Titanium gel made from metallic titanium and hydrogen peroxide10.1016/0021-9797(89)90117-3 ↗
54. Surface modified Ti6Al4V for enhanced bone bonding ability–Effects of silver and corrosivity at simulated physiological conditions from a corrosion and metal release perspective10.1016/j.corsci.2020.108566 ↗
55. Reactivity and corrosion behaviors of Ti6Al4V alloy implant biomaterial under metabolic perturbation conditions in physiological solutions10.3390/ma14237404 ↗
56. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide10.1002/jbm.820280115 ↗
57. Electrochemical polarization: I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
58. Corrosion behaviour of selective laser melted Ti-TiB biocomposite in simulated body fluid10.1016/j.electacta.2017.02.112 ↗
59. Microstructural aspects of Ti6Al4V degradation in H2O2-containing phosphate buffered saline10.1016/j.corsci.2021.109640 ↗
60. Improved corrosion behaviour of electron beam melted Ti-6Al–4V alloy in phosphate buffered saline10.1016/j.corsci.2017.05.003 ↗
61. The effect of hydrogen peroxide on the electrochemical behavior of Ti and some of its alloys for dental applications10.1016/j.matchemphys.2005.10.032 ↗
62. Effect of inflammatory conditions and H2O2 on bare and coated Ti–6Al–4V surfaces: corrosion behavior, metal ion release and Ca-P formation under long-term immersion in DMEM10.1016/j.apsusc.2015.08.261 ↗
63. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
64. Corrosion resistance characteristics of a Ti-6Al-4V alloy scaffold that is fabricated by electron beam melting and selective laser melting for implantation in vivo10.1016/j.msec.2016.07.045 ↗
65. Mechanical, electrochemical and biological behavior of 3D printed-porous titanium for biomedical applications10.1007/s40735-020-00457-5 ↗
66. On the intrinsic coupling between constant-phase element parameters α and Q in electrochemical impedance spectroscopy10.1016/j.electacta.2012.04.020 ↗
67. The analysis of electrode impedances complicated by the presence of a constant phase element10.1016/S0022-0728(84)80324-1 ↗
68. Effect of fluoride ions on corrosion behaviour of commercial pure titanium in artificial seawater environment10.1016/j.apsusc.2019.144759 ↗
69. Fundamentals of impedance spectroscopy
70. Lvovich · 2012 · 37
71. Corrosion of materials
72. A closer look at the in vitro electrochemical characterisation of titanium alloys for biomedical applications using in-situ methods10.1016/j.actbio.2017.03.022 ↗
73. Corrosion behavior of titanium in artificial saliva by lactic acid10.3390/ma7085528 ↗
74. Abd El Rehim SS, Ibrahim MA, El Boraei NF. The bifunctional role played by thiocyanate anions on the active dissolution and the passive film of titanium in hydrochloric acid. Corrosion Engineering
75. Different passivation behavior between α and β phases of Ti-6Al-4V in HCl solutions under oxygenated/deoxygenated conditions10.1016/j.apsusc.2022.154539 ↗
76. Role of pH-induced structural change in protein aggregation in foam fractionation of bovine serum albumin10.1016/j.btre.2016.01.002 ↗
77. Effect of the electrochemical characteristics of titanium on the adsorption kinetics of albumin10.1039/C9RA05988A ↗
78. Role of protein adsorption in the bio corrosion of metallic implants–a review10.1016/j.colsurfb.2019.01.038 ↗
79. Preliminary study of adsorption behavior of bovine serum albumin (BSA) protein and its effect on antibacterial and corrosion property of Ti-3Cu alloy10.1016/j.jmst.2020.11.046 ↗
80. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium10.1016/j.actbio.2005.09.004 ↗
81. Effects of competitive anion adsorption (Br- or Cl-) and semiconducting properties of the passive films on the corrosion behavior of the additively manufactured Ti-6Al-4V alloys10.1016/j.corsci.2020.108789 ↗
82. Corrosion behavior of novel titanium-based composite with engineering 3D artificial nacre-like structures10.1016/j.compositesa.2022.107278 ↗
83. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an in Vitro model of peri-implant inflammation10.1371/journal.pone.0210530 ↗