Role of Ta in improving corrosion resistance of titanium alloys under highly reducing condition
Source abstract
Abstract
Great improvement on corrosion resistance was achieved by adding small amount of Ta into ASTM Gr13 titanium alloy. Main contribution to the improved corrosion resistance originated from the stabilized passive film in terms of the prolonged time to passivity loss. OCP results showed that the OCP transition from the passive state to corroding one prolonged with the Ta content. This behavior was also supported by EIS results, where the loop shrinkage denoting the passivity loss was retarded and/or inhibited by the Ta addition. Microstructural analysis revealed that the added Ta functioned as both substitution element and solid solution one, leading to the growth of the precipitates including β-Ti phase and formation of the complex structured passive film. Especially, the prominent stability of the passive film observed for Gr13–1.0% Ta was ascribed to the high content of the Ta oxide in the passive film, meaning that the complex oxide film required the minimum amount of the Ta oxide to obtain the excellent stability of the passive film against the high concentrated acid solution.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. Design and mechanical properties of new β type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
2. Leyens · 2003
3. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
4. Corrosion of titanium: Part 1: aggressive environments and main forms of degradation
5. Environmental behavior of beta titanium alloys10.1007/BF03220744 ↗
6. Surface modification methods for titanium and its alloys and their corrosion behavior in biological environment: a review10.1007/s40735-019-0229-5 ↗
7. Jackson · 1966
8. Corrosion behavior and use of titanium and its alloys10.1007/BF03338589 ↗
9. Been · 2011 · 861
10. The role of palladium in enhancing corrosion resistance of titanium10.1595/003214067X1125052 ↗
11. Effect of palladium on the corrosion behavior of titanium10.1016/j.corsci.2003.10.003 ↗
12. Analyzing the influence of alloying elements and impurities on the localized reactivity of titanium grade-7 by scanning electrochemical microscopy10.1021/ac701796u ↗
13. Lütjering · 2007 · 175
14. Ruthenium enhanced titanium alloys10.1595/003214096X4025461 ↗
15. The potential of ruthenium as an alloying element in titanium
16. The influence of noble metal alloy additions on the electrochemical and corrosion behavior of titanium10.1149/1.2427493 ↗
17. Passivity and corrosion resistance of titanium and its alloys10.1149/1.2428023 ↗
18. Corrosion resistance of titanium-ruthenium alloys10.5006/0010-9312-31.2.60 ↗
19. Cathodic modification as a means of improving the corrosion resistance of alloys10.1007/BF01094295 ↗
20. Passivation of cathodically modified alloys10.1179/000705989798269876 ↗
21. A review of corrosion of titanium grade 7 and other titanium alloys in nuclear waste repository environments10.5006/1.3280899 ↗
22. Ishii · 2002 · 45
23. Characteristics and applications of high corrosion resistant titanium alloys
24. Brown · 1996
25. Kulkarni · 2014 · 111
26. Corrosion in titanium dental implants/prostheses–a review
27. Review of the anatase to rutile phase transformation10.1007/s10853-010-5113-0 ↗
28. Structure and composition of passive titanium oxide films10.1016/S0921-5107(97)00043-3 ↗
29. Corrosion and serration behaviors of TiZr0. 5NbCr0. 5V x Mo y high entropy alloys in aqueous environments10.3390/met4040597 ↗
30. Electrochemical behaviour of Ti alloys containing Mo and Ta as β-stabilizer elements for dental application10.1016/S1003-6326(13)62936-2 ↗
31. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
32. Effect of alloying elements on corrosion properties of high corrosion resistant titanium alloys in high concentrated sulfuric acid
33. Characterization of passive oxide film on a Ti–5% Ta–1.8% Nb alloy on exposure to severe oxidizing conditions10.1016/j.matchar.2010.08.009 ↗
34. Corrosion resistance and biocompatibility of Ti–Ta alloys for biomedical applications10.1016/j.msea.2005.03.032 ↗
35. Influence of concentration and temperature on the corrosion behavior of titanium, titanium-20 and 40% tantalum alloys and tantalum in sulfuric acid solutions10.1016/j.matchemphys.2007.02.026 ↗
36. Comparative corrosion study of Ti–Ta alloys for dental applications10.1016/j.actbio.2009.05.037 ↗
37. Ti–25Ta alloy with the best mechanical compatibility in Ti–Ta alloys for biomedical applications10.1016/j.msec.2008.09.012 ↗
38. Microstructures and mechanical properties of Ti–50 mass% Ta alloy for biomedical applications10.1016/j.jallcom.2007.11.090 ↗
39. Evaluation of mechanical and corrosion biocompatibility of TiTa alloys10.1023/A:1011210101895 ↗
40. Influence of fluoride concentration and pH on corrosion behavior of Ti-6Al-4V and Ti-23Ta alloys in artificial saliva10.1002/maco.200604004 ↗
41. Effects of Nb and Zr alloying additions on the activation behavior of Ti in hydrochloric acid10.1149/1.1392655 ↗
42. The influence of fluoride ions on the passive dissolution of titanium10.1016/0013-4686(79)87084-X ↗
43. Corrosion rate of titanium in H2SO410.1016/S0254-0584(97)80079-X ↗
44. Comparison of the corrosion behavior of pure titanium and its alloys in fluoride-containing sulfuric acid10.1016/j.corsci.2015.11.003 ↗
45. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
46. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials10.1016/S0142-9612(00)00309-4 ↗
47. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
48. EIS study of Ti and its alloys in biological media10.1016/S0022-0728(02)00814-8 ↗
49. Film formation and characterization of anodic oxides on titanium for biomedical applications, Surface and Interface Analysis10.1002/sia.2261 ↗
50. Improvement in corrosion resistance of commercial pure titanium for the enhancement of its biocompatibility10.1002/maco.200905534 ↗
51. The effect of fluoride ions on the corrosion behavior of pure titanium in 0.05 M sulfuric acid10.1016/j.electacta.2014.05.055 ↗
52. A kinetic model for the anodic dissolution of Ti in HF in the active and passive regions10.1149/2.0251509jes ↗
53. Microstructural evolution and its effect on corrosion behavior and mechanism of an austenite-based low-density steel during aging10.1016/j.corsci.2022.110936 ↗
54. Comparison of various properties between titanium-tantalum alloy and pure titanium for biomedical applications10.2320/matertrans.48.380 ↗
55. Limits of substitution of titanium for tantalum in corrosion resistant alloys10.5006/0010-9312-18.6.205 ↗