Comparison of the wettability and corrosion resistance of two biomedical Ti alloys free of toxic elements with those of the commercial ASTM F136 (Ti–6Al–4V) alloy
Source abstract
Abstract
Titanium alloys have been widely used as biomaterials. However, contact of titanium with body fluids can release toxic ions due to degradation. The present work aimed to compare the wettability and corrosion resistance of two Ti alloys without toxic ions, Ti–30Nb–7Zr (TNZ) and Ti–47Nb (TN), with those of the commercial biomedical alloy Ti–6Al–4V-ELI (ASTM F136). Corrosion studies were carried out in a three-electrode cell conventional system, which Ti alloys as working electrodes were exposed to 0.9% sodium chloride electrolyte at 37 °C to determine if they have surface properties adequate for biomedical applications. α and β phases present on the microstructure were distinguished using scanning electron microscopy (SEM). Chemical surface composition was performed using X-ray photoelectron spectroscopy (XPS) analysis. Surface energy was determined by wettability testing. For TN and TNZ alloys the microstructure consisted of a β matrix, although only TNZ exhibited α precipitates. In contrast, F136 alloy microstructure presents α matrix, which was strengthened by the β phase. All alloys tested exhibited an increase in corrosion potential with the immersion time, indicating the growth and stabilization of the passive oxide film. The results showed that ASTM F136 is more hydrophilic but less corrosion resistant than the TN and TNZ alloys. It remains to be seen in practical applications whether the lower hydrophobicity of TN and TNZ alloys is compensated by lower toxicity and higher corrosion resistance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Systemic levels of metallic ions released from orthodontic mini-implants10.1016/j.ajodo.2007.04.045 ↗
2. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants10.1016/j.dental.2014.10.002 ↗
3. Ultrafine grained titanium for biomedical applications: an overview of performance10.1016/j.jmrt.2013.07.003 ↗
4. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
5. Brunette · 2001 · 26
6. Sequential bone healing of immediately loaded mini-implants: histomorphometric and fluorescence analysis10.1016/j.ajodo.2007.12.035 ↗
7. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: a systematic review10.1016/j.jtemb.2020.126618 ↗
8. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
9. Effects of solution treatment and aging on the microstructure, mechanical properties, and corrosion resistance of a type Ti-Ta-Hf-Zr alloy
10. An investigation of the mechanical and microstructural evolution of a TiNbZr alloy with varied ageing time10.1038/s41598-018-24155-y ↗
11. Precipitation hardening and microstructure evolution of the Ti–7Nb–10Mo alloy during aging10.1016/j.msec.2016.03.030 ↗
12. The competition between the alpha and omega phases in aged Ti-Nb alloys10.1007/BF02645136 ↗
13. The role of crack origin size and early stage crack growth on high cycle fatigue of powder metallurgy Ti-6Al-4V alloy10.1016/j.ijfatigue.2017.05.004 ↗
14. Electrochemical characterization and passivation behaviour of new beta-titanium alloys (Ti35Nb10Ta-xFe)10.1016/j.electacta.2016.12.125 ↗
15. Characterization, corrosion behavior, cellular response and in vivo bone tissue compatibility of titanium–niobium alloy with low Young's modulus10.1016/j.msec.2015.10.062 ↗
16. Corrosion behaviour of Ti–34Nb–25Zr alloy fabricated by spark plasma sintering
17. A study on corrosion resistance of the Ti-10Mo experimental alloy after different processing methods10.1016/j.msec.2004.08.013 ↗
18. Caracterização superficial e análise de corrosão das ligas Ti-6Al-4V e Ti-Mo em meios fluoretados
19. On the corrosion behaviour of low modulus titanium alloys for medical implant applications: a review10.3390/met9080878 ↗
20. Roughness induced dynamic changes of wettability of acid etched titanium implant modifications10.1016/j.biomaterials.2003.08.015 ↗
21. Characterisation of titanium passivation films by in situ ac impedance measurements and XPS analysis10.1016/0022-0728(94)87136-1 ↗
22. Surface microstructures and corrosion resistance of Ni-Ti-Nb shape memory thin films10.1016/j.apsusc.2017.04.070 ↗
23. The influence of microstructure on the passive layer chemistry and corrosion resistance for some titanium-based alloys10.3390/ma12081233 ↗
24. Resolving surface chemical states in XPS analysis of first row transition metals, oxides and hydroxides: Sc, Ti, V, Cu and Zn10.1016/j.apsusc.2010.07.086 ↗
25. Electrochemical corrosion behavior of a Ti–35Nb alloy for medical prostheses10.1016/j.electacta.2008.02.011 ↗
26. Accuracy of the Tougaard method for quantitative surface analysis. Comparison of the Universal and REELS inelastic cross sections10.1016/0368-2048(92)80025-4 ↗
27. Understanding the wetting properties of nanostructured selenium coatings: the role of nanostructured surface roughness and air-pocket formation
28. Direct production of Ti–29Nb–13Ta–4.6 Zr biomedical alloy from oxide mixture in molten CaCl210.1149/1.3435302 ↗
29. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
30. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
31. Studies on cell-biomaterial interaction: role of tyrosine phosphorylation during fibroblast spreading on surfaces varying in wettability10.1016/0142-9612(96)84943-X ↗
32. Topography and surface energy of dental implants: a methodological approach10.1007/s40430-016-0700-x ↗
33. Influence of nanoporous titanium niobium alloy surfaces produced via hydrogen peroxide oxidative etching on the osteogenic differentiation of human mesenchymal stromal cells10.1016/j.msec.2019.01.023 ↗
34. Interpretation of protein adsorption: surface induced conformational changes10.1021/ja042898o ↗
35. Development of Ti–Nb–Zr alloys with high elastic admissible strain for temporary orthopedic devices10.1016/j.actbio.2015.03.023 ↗
36. Progess in superhydrophobic surface development10.1039/B712575P ↗
37. Development of Ti–Nb–Zr alloys with high elastic admissible strain for temporary orthopedic devices10.1016/j.actbio.2015.03.023 ↗