Characterisation of geometrical and physical properties of a stainless steel denture framework manufactured by single-point incremental forming
Source abstract
Abstract
In recent years, numerous scientific and technological innovations have been introduced in the fields of medicine and dentistry. The application of computer-based engineering techniques has enabled significant improvement in the design and performance of biomedical components, including implants and prostheses. Innovative and flexible manufacturing methods, such as single point incremental forming (SPIF), allow the cost-effective production of these “custom-made” components. The SPIF technology has been employed to manufacture a metal denture base plate (framework) of a complete maxillary (upper) denture to replace a traditional prosthodontic procedure based on a lost-wax technique, which is time-consuming and requires much manual work. Stainless steel sheet of quality X6Cr17 and thickness of 0.5 mm was adopted due to its biocompatibility, good mechanical properties, and reasonable price. The SPIF process was completely designed in a digital environment with a focus on achieving high quality and accuracy of the part followed by experimental verification. For validation, the formed part was compared in terms of the geometry and mechanical strength with the reference one fabricated using the lost-wax technique. The results obtained confirmed the high dimensional accuracy and good strength of the SPIF-made part. The experimental investigations also included analysis of sheet thinning, surface roughness, and microstructure.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Metal Forming Simulation Techniques · Laser and Thermal Forming Techniques · Advanced Surface Polishing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Polyamide as a denture base material: a literature review
2. The mechanical properties of moulded and thermoformed denture resins10.5545/sv-jme.2014.2249 ↗
3. Titanium complete denture base in a patient with heavy bruxism: a clinical report
4. Design of complete denture reinforced with metal base10.2298/SGS1301015P ↗
5. Gibson · 2005
6. Evaluation of different materials used for fabrication of complete digital denture10.37358/MP.18.1.4977 ↗
7. Klim · 2008
8. Frigolé · 2017
9. Manufacture of absorber fins for solar collector using incremental sheet forming10.1016/j.jmrt.2018.07.018 ↗
10. Single point incremental forming: state-of-the-art and prospects10.1007/s12289-017-1387-y ↗
11. Incremental sheet forming towards biomedical implants: a review10.1016/j.jmrt.2020.04.096 ↗
12. Evaluation of formability and fracture of pure titanium in incremental sheet forming10.1007/s00170-017-1195-z ↗
13. Incremental forming of titanium Ti6Al4V alloy for cranioplasty base plates - decision-making process and technological approaches10.3390/met8080626 ↗
14. Application of Incremental Forming process for high customised medical product manufacturing10.1016/j.jmatprotec.2005.02.148 ↗
15. A paradigm to produce customized ankle support using incremental sheet forming10.4103/0976-8580.149474 ↗
16. Eksteen · 2013
17. Experimental study on the surface quality of the medical implants obtained by single point incremental forming10.1007/s12289-010-0922-x ↗
18. Contribution to a biomedical component production using incremental sheet forming10.1007/s00170-017-1397-4 ↗
19. Production of thin shell clavicle implants through single point incremental forming
20. Single point incremental forming of a medical implant10.4028/www.scientific.net/KEM.554-557.1388 ↗
21. Manufacture of accurate titanium cranio-facial implants with high forming angle using single point incremental forming10.4028/www.scientific.net/KEM.549.223 ↗
22. Recent approaches for the manufacturing of polymeric cranial prostheses by incremental sheet forming
23. Incremental sheet metal forming process for pure titanium denture plate
24. Efficiency of optimization algorithms on the adjustment of process parameters for geometric accuracy enhancement of denture base plate in single point incremental sheet forming
25. Titanium as a reconstruction and implant material in dentistry: advantages and pitfalls10.3390/ma5091528 ↗
26. Investigation of sheet-titanium drawability
27. Forming of titanium and titanium alloys
28. Conventional and contemporary polymers for the fabrication of denture prosthesis: part I-overview, composition and properties
29. Santonen · 2010
30. Review of materials in medical applications
31. Stainless steel: material facts for the orthodontic practitioner10.16925/od.v11i20.751 ↗
32. Application of single point incremental forming for manufacturing of denture base
33. Recent advances in dental optics – Part I: 3D intraoral scanners for restorative dentistry10.1016/j.optlaseng.2013.07.017 ↗
34. 2016
35. Integrating a new software tool used for tool path generation in the numerical simulation of incremental forming processes10.5545/sv-jme.2018.5475 ↗
36. Towards smart manufacturing techniques using incremental sheet forming
37. Optimization techniques applied to single point incremental forming process for biomedical application10.1007/s00170-017-1305-y ↗
38. Numerical simulation and experimental investigation of incremental sheet forming process10.1007/s11771-008-0109-5 ↗
39. An experimental study on the influence of tool path, tool diameter and pitch in single point incremental forming (SPIF)10.1080/2374068X.2015.1128171 ↗
40. Investigation of surface roughness in incremental sheet forming10.1016/j.procs.2018.07.074 ↗
41. Forming parameters and forming defectsin incremental forming process: Part B10.1080/10426914.2014.880457 ↗
42. Parameters for the FEA simulations of single point incremental forming10.1080/21693277.2019.1608330 ↗
43. Titanium for removable dentures. I. Laboratory procedures10.1111/j.1365-2842.1997.tb00337.x ↗
44. Roughness evaluation of single point incrementally formed surfaces
45. Evaluation of the effect of denture cleansers on the surface roughness of hard denture base material: an in vitro study10.4103/ijdr.IJDR_810_16 ↗
46. Evaluation of strain and stress states in the single point incremental forming process10.1007/s00170-015-7954-9 ↗
47. Prediction and control of pillow defect in single point incremental forming using numerical simulations10.1007/s12206-016-0422-0 ↗
48. Soltanzadeh · 2018
49. Experimental investigation of the mechanical performances of titanium cranial prostheses manufactured by super plastic forming and single-point incremental forming10.1007/s00170-018-2338-6 ↗
50. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks10.1243/095441105X9372 ↗
51. Accuracy of CAD-CAM-fabricated removable partial dentures10.1016/j.prosdent.2017.04.017 ↗
52. Comparative evaluation of the dimensional accuracy of cast partial denture frameworks fabricated by a conventional technique and light-cure wax technique: an in vitro study10.4103/kleuhsj.kleuhsj_245_17 ↗
53. Comparison of the midline stress fields in maxillary and mandibular complete dentures: a pilot study10.1016/j.prosdent.2005.11.009 ↗
54. Fracture strength of metal-based complete maxillary dentures with a newly designed metal framework
55. Influence of a denture strengthener on the deformation of a maxillary complete denture10.4012/dmj.28.507 ↗
56. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue10.3109/00016358909167305 ↗
57. A study of stress distribution in complete upper denture