Effect of minor gallium addition on corrosion, passivity, and antibacterial behaviour of novel β-type Ti–Nb alloys
Source abstract
Abstract
Metastable Ti-Nb alloys are promising bone-implant materials due to improved mechanical biofunctionality and biocompatibility. To overcome increasing bacterial infection risk, alloying with antibacterial elements is a promising strategy. This study investigates the effect of minor gallium (Ga) additions (4, 8 wt.% Ga) to as-cast and solution-treated β-type Ti-45Nb-based alloy (96(Ti-45Nb)-4Ga, 92(Ti-45Nb)-8Ga (wt.%)) on corrosion and passive film properties, as well as cytocompatibility and antibacterial activity. The electrochemical properties were evaluated by potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and Mott-Schottky analyses in phosphate-buffered saline (PBS). X-ray photoelectron spectroscopy (XPS) was performed to analyze the chemical composition of passive films. Early adhesion and viability of macrophages and Staphylococcus aureus were assessed by nucleocounting and colony-forming unit counting, respectively. The results showed that high corrosion resistance and passive film properties of Ti-45Nb are retained and even slightly improved with Ga. EIS results revealed that Ga addition improves the passive film resistance. XPS measurements of 92(Ti-45Nb)-8Ga show that the passive film contains Ti-, Nb- and Ga-based oxides, implying the formation of mixed (Ti-Nb-Ga) oxides. In addition, marginal Ga ion release rate was detected under free corrosion conditions. Therefore, it can be assumed that Ga species may contribute to passive film formation on Ga-containing alloys. The 92(Ti-45Nb)-8Ga elicited an antibacterial effect against S. aureus compared to cp-Ti at 4 h. Moreover, Ga-containing alloys showed good cytocompatibility with THP-1 macrophages at 24 h. In conclusion, it was demonstrated that Ga additions to Ti-45Nb are beneficial to corrosion resistance and showed promising initial host and bacterial interactions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (74)
Show source-provided references
1. Ti–Mo–Zr alloys for bone repair: mechanical properties, corrosion resistance, and biological performance10.1016/j.jmrt.2023.05.006 ↗
2. New developments of ti-based alloys for biomedical applications10.3390/ma7031709 ↗
3. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus10.1016/j.actbio.2011.02.008 ↗
4. Design and processing of near-β Ti–Nb–Ag alloy with low elastic modulus and enhanced corrosion resistance for orthopedic implants10.1016/j.jmrt.2023.03.003 ↗
5. Assessment of the genetic risks of a metallic alloy used in medical implants10.1590/S1415-47572010005000118 ↗
6. In situ elaboration of a binary Ti-26Nb alloy by selective laser melting of elemental titanium and niobium mixed powders10.1016/j.msec.2016.02.033 ↗
7. Comparison of the wettability and corrosion resistance of two biomedical Ti alloys free of toxic elements with those of the commercial ASTM F136 (Ti–6Al–4V) alloy10.1016/j.jmrt.2020.11.068 ↗
8. Microstructure, corrosion and anti-bacterial investigation of novel Ti-xNb-yCu alloy for biomedical implant application10.1016/j.jmrt.2022.04.158 ↗
9. Targeting implant-associated infections: titanium surface loaded with antimicrobial10.1016/j.isci.2020.102008 ↗
10. Biofilm properties in relation to treatment outcome in patients with first-time periprosthetic hip or knee joint infection
11. The antibacterial activity of Ga3+ is influenced by ligand complexation as well as the bacterial carbon source10.1128/AAC.00386-11 ↗
12. Metallurgical gallium additions to titanium alloys demonstrate a strong time-increasing antibacterial activity without any cellular toxicity10.1021/acsbiomaterials.9b00147 ↗
13. Effect of heat treatment on the corrosion resistance of selective laser melted Ti6Al4V3Cu alloy10.1016/j.jmrt.2021.03.041 ↗
14. Antimicrobial activity of gallium compounds on ESKAPE pathogens
15. Gallium disrupts bacterial iron metabolism and has therapeutic effects in mice and humans with lung infections10.1126/scitranslmed.aat7520 ↗
16. Promises and failures of gallium as an antibacterial agent10.2217/fmb.14.3 ↗
17. The transition metal gallium disrupts Pseudomonas aeruginosa iron metabolism and has antimicrobial and antibiofilm activity10.1172/JCI30783 ↗
18. Mechanical compatibility of titanium implants in hard tissues10.1016/j.ics.2005.06.084 ↗
19. Effect of indium (In) on corrosion and passivity of a beta-type Ti-Nb alloy in Ringer’s solution10.1016/j.apsusc.2015.02.058 ↗
20. Novel low modulus beta-type Ti-Nb alloys by gallium and copper minor additions for antibacterial implant applications10.1016/j.jmrt.2022.08.111 ↗
21. Elastic softening of β-type Ti-Nb alloys by indium (In) additions10.1016/j.jmbbm.2014.07.010 ↗
22. Thermal stability and phase transformations of martensitic Ti-Nb alloys10.1088/1468-6996/14/5/055004 ↗
23. Chemical nanoroughening of Ti40Nb surfaces and its effect on human mesenchymal stromal cell response10.1002/jbm.b.32976 ↗
24. Characterization of thin anodic oxides of Ti-Nb alloys by electrochemical impedance spectroscopy10.1016/j.electacta.2012.06.029 ↗
25. Comparative study on the corrosion behavior of Ti-Nb and TMA alloys for dental application in various artificial solutions10.1016/j.msec.2010.12.010 ↗
26. Anodic oxides on a beta type Nb-Ti alloy and their characterization by electrochemical impedance spectroscopy
27. Surface treatment, corrosion behavior, and apatite-forming ability of ti-45Nb implant alloy10.1002/jbm.b.32836 ↗
28. Grain boundary electrochemistry of β-type Nb-Ti alloy using a scanning droplet cell
29. Corrosion and tribocorrosion behavior of Ti-40Nb and Ti-25Nb-5Fe alloys processed by powder metallurgy10.1007/s11661-020-05757-6 ↗
30. A new Ti-15Zr-4Nb-4Ta alloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
31. Corrosion behavior of a low modulus β-Ti-45%Nb alloy for use in medical implants10.1007/s10856-006-6330-6 ↗
32. Special modes of corrosion under physiological and simulated physiological conditions10.1016/j.actbio.2007.12.003 ↗
33. Corrosion aspects of metallic implants - an overview10.1002/maco.200804173 ↗
34. Electrochemical impedance spectroscopic characterisation of passive film formed over β Ti-29Nb-13Ta-4.6Zr alloy10.1016/j.elecom.2006.06.004 ↗
35. Effects of Zr content on microstructure and corrosion resistance of Ti-30Nb-Zr casting alloys for biomedical applications10.1016/j.electacta.2007.10.060 ↗
36. Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
37. Designing the microstructural constituents of an additively manufactured near β Ti alloy for an enhanced mechanical and corrosion response10.1016/j.matdes.2022.110618 ↗
38. Oxidation treatments of beta-type Ti-40Nb for biomedical use10.1016/j.surfcoat.2016.05.036 ↗
39. Problem of stress shielding and improvement to the hip implant designs: a review10.3923/jms.2007.460.467 ↗
40. Tribology international tribocorrosion behavior of β -type Ti-Nb-Ga alloys in a physiological solution10.1016/j.triboint.2023.108325 ↗
41. Effects of Ga on the structural, mechanical and electronic properties of β-Ti-45Nb alloy by experiments and ab initio calculations10.1016/j.jmbbm.2023.105728 ↗
42. Assessment of β stabilizers additions on microstructure and properties of as-cast β Ti-Nb based alloys10.1016/j.jmrt.2022.12.144 ↗
43. Standard electrode potentials and temperature coefficients in water at 298.15 K10.1063/1.555839 ↗
44. Tables of standard electrode potentials10.1149/1.2131790 ↗
45. Characteristics of passive films formed on As-Cast Ti–6Al-4V in Hank’s solution before and after transpassivation10.3389/fmats.2020.640081 ↗
46. Presentation of an Atlas of chemical and electrochemical equilibria in the presence of a gaseous phase10.4028/www.scientific.net/MSF.251-254.143 ↗
47. Determination of Polarization resistance and corrosion rate by using pulse method, polarization curves and AAS10.1002/maco.19820331204 ↗
48. Thin anodic oxide layers on aluminium and other valve metals: high field regime
49. Revealing the relationship between grain size and corrosion rate of metals10.1016/j.scriptamat.2010.08.035 ↗
50. Corrosion resistance of nanostructured titanium10.1016/j.bioeng.2007.08.007 ↗
51. Balyanov · Corrosion resistance of ultra fine-grained Ti · 2004 · 51 · 225
52. Comparative effect of grain size and texture on the corrosion behaviour of commercially pure titanium processed by equal channel angular pressing10.1016/j.corsci.2009.08.017 ↗
53. Corrosion behavior and characteristics of passive films of laser powder bed fusion produced Ti–6Al–4V in dynamic Hank’s solution10.1016/j.matdes.2021.109907 ↗
54. Corrosion and passivation behavior of laser powder bed fusion produced Ti-6Al-4V in static/dynamic NaCl solutions with different concentrations10.1016/j.corsci.2021.109728 ↗
55. Microelectrode techniques for corrosion research of iron10.1016/j.electacta.2013.03.021 ↗
56. Passivity of dual-phase carbon steel with ferrite and martensite phases in pH 8.4 boric acid-borate buffer solution10.1149/2.0471507jes ↗
57. Electronic properties of passive films from the multi-frequency Mott-Schottky and power-law coupled approach10.1016/j.elecom.2016.03.003 ↗
58. Effect of microstructural defects on passive layer properties of interstitial free (IF) ferritic steels in alkaline environment10.1016/j.corsci.2021.109271 ↗
59. Quantitative analysis of local fine structure on diffusion of point defects in passive film on Ti10.1016/j.electacta.2019.05.048 ↗
60. Corrosion behavior and mechanism of selective laser melted Ti35Nb alloy produced using pre-alloyed and mixed powder in Hank’s solution
61. High-throughput synthesis and characterization of anodic oxides on Nb-Ti alloys10.1016/j.electacta.2009.02.104 ↗
62. Corrosion behavior of As-Cast Ti–10Mo–6Zr–4Sn–3Nb and Ti–6Al–4B in hank’s solution: A comparison investigation
63. Electrochemical behaviour of passive film formed on the surface of Ti-6Al-4V alloys fabricated by electron beam melting10.1016/j.corsci.2018.09.010 ↗
64. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
65. Rolled-Up Metal Oxide Microscaffolds to Study Early Bone Formation at Single Cell Resolution
66. Atomic–scale investigations of passive film formation on Ti-Nb alloys10.1016/j.apsusc.2022.156282 ↗
67. α-Ga 2 O 3 as a photocatalyst in the degradation of malachite green10.1149/2.0351907jss ↗
68. Mechanical properties and shape memory behavior of Ti-Mo-Ga alloys10.2320/matertrans.45.1090 ↗
69. Metal release and cell biological compatibility of beta-type Ti-40Nb containing indium10.1002/jbm.b.33976 ↗
70. Oxygen vacancy induced band-gap narrowing and enhanced visible light photocatalytic activity of ZnO10.1021/am300835p ↗
71. Electrochemistry of gallium10.33961/JECST.2013.4.1.1 ↗
72. Biomaterials-mediated regulation of macrophage cell fate10.3389/fbioe.2020.609297 ↗
73. The different microbial etiology of prosthetic joint infections according to route of acquisition and time after prosthesis implantation, including the role of multidrug-resistant organisms10.3390/jcm8050673 ↗
74. The significance of infection related to orthopedic devices and issues of antibiotic resistance10.1016/j.biomaterials.2005.11.044 ↗