journal article·2024-11Open access

Plasma electrolytic oxidation deposited HAp-Ta2O5 composite coatings on Ti6Al4V for biomedical applications: The importance of Ta2O5 reinforcing phase

Milad Hosseini, Jafar Khalil-Allafi, Mir Saman Safavi

Abstract

In this research, the focus was placed on enhancing the properties of hydroxyapatite (HAp) coating by the addition of various concentrations of tantalum pentoxide (Ta 2 O 5 ) nanoparticles, ranging from 0 to 1.5 g/L, to its electrolyte solution. The HAp-Ta 2 O 5 composite coatings were deposited on the Ti6Al4V metallic implant using the plasma electrolytic oxidation technique. The results of the X-ray diffraction test indicated that the increased concentration of Ta 2 O 5 nanoparticles has no significant effect on the phase composition of the coatings. The denser and rougher coatings were fabricated when 1.5 g/L of Ta 2 O 5 nanoparticles were added to the solution. The favorable microstructural properties of the HAp-1.5 g/L Ta 2 O 5 composite coating resulted in a notable improvement in the mechanical properties, i.e., >40% increase in both microhardness and bonding strength compared to HAp. The corrosion resistance of the coated implants was evaluated through electrochemical impedance spectroscopy and potentiodynamic polarization tests. The inclusion of Ta 2 O 5 nanoparticles in HAp coating led to a 72% reduction in the corrosion current density of HAp, indicating the constructive contribution of the nanoparticles to improved corrosion protection. The samples were incubated in simulated body fluid for 7 days to assess their in vitro immersion performance. All of the PEO-derived coatings stimulated the nucleation and growth of apatite grains, showing their superior biomineralization ability. An obvious decrease in the level of harmful ions such as Al 3+ and V 5+ released from the surface of composite coatings was obtained. These findings suggest that the developed system has potential for dental and orthopedic applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Surface modified NiTi smart biomaterials: surface engineering and biological compatibility
2. Electrodeposited hydroxyapatite-based biocoatings: recent progress and future challenges10.3390/coatings11010110 ↗
3. Progress in niobium oxide-containing coatings for biomedical applications: a critical review10.1021/acsomega.2c00440 ↗
4. Improved osteogenic activity of NiTi orthopedic implant by HAp-Nb2O5 composite coatings: materials and biological points of view10.1016/j.bioadv.2023.213435 ↗
5. Effectiveness of physicochemical techniques on the activation of Ti6Al4V surface with improved biocompatibility and antibacterial properties
6. Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element10.1016/j.jmbbm.2015.04.015 ↗
7. In-vitro and in-vivo bio-corrosion and biocompatibility responses of bioactive TiTaNb films with various Ta contents on Ti6Al4V implants10.1016/j.jmrt.2023.06.216 ↗
8. Laser surface texturing of Ti-cp and Ti6Al4V alloy for the improvement of fibroblast adhesion and alignment and the reduction of bacterial adhesion10.1016/j.jmrt.2024.03.033 ↗
9. Tackling the challenges facing the clinical applications of pure PEO hydroxyapatite layers: Co-deposition of YSZ nanoparticles10.1016/j.matchemphys.2022.126899 ↗
10. Effect of zirconia coating on Ti6Al4V at elevated substrate temperature on its wear, corrosion and hemocompatibility properties10.1016/j.ceramint.2024.05.006 ↗
11. Advances in hydroxyapatite coatings on biodegradable magnesium and its alloys10.1016/j.jma.2022.01.001 ↗
12. Enhanced in vitro immersion behavior and antibacterial activity of NiTi orthopedic biomaterial by HAp-Nb2O5 composite deposits10.1038/s41598-023-43393-3 ↗
13. Encouraging tribomechanical and biological responses of hydroxyapatite coatings reinforced by various levels of niobium pentoxide particles10.1039/D3MA00704A ↗
14. Effect of doping in hydroxyapatite as coating material on biomedical implants by plasma spraying method: a review10.1016/j.ceramint.2020.10.112 ↗
15. Investigation on microstructure, mechanical, and tribological performance of Cu base hybrid composite materials10.1016/j.jmrt.2021.11.114 ↗
16. Effect of ball-milling process parameters on mechanical properties of Al/Al2O3/collagen powder composite using statistical approach10.1016/j.jmrt.2021.09.082 ↗
17. Experimental investigation and optimization of compression moulding parameters for MWCNT/glass/kevlar/epoxy composites on mechanical and tribological properties10.1016/j.jmrt.2021.08.037 ↗
18. Ion-substituted calcium phosphate coatings by physical vapor deposition magnetron sputtering for biomedical applications: a review10.1016/j.actbio.2019.03.006 ↗
19. Electrophoretic deposition of biocompatible and bioactive hydroxyapatite-based coatings on titanium10.3390/ma14185391 ↗
20. Improved corrosion protection of a NiTi implant by an electrodeposited HAp-Nb2O5 composite layer10.1016/j.surfcoat.2023.129822 ↗
21. Characterization of thermal-sprayed HAP and HAP/TiO2 coatings for biomedical applications10.1007/s11666-018-0766-3 ↗
22. One-step fabrication of double-layer nanocomposite coating by plasma electrolytic oxidation with particle addition10.1016/j.apsusc.2022.153043 ↗
23. Micro and nano-enabled approaches to improve the performance of plasma electrolytic oxidation coated magnesium alloys10.1016/j.jma.2020.11.004 ↗
24. Growth, microstructure and mechanical properties of micro-arc oxidation coatings on titanium alloy in phosphate-containing solution10.1016/j.apsusc.2004.03.231 ↗
25. Electrolytic plasma processing for cleaning and metal-coating of steel surfaces10.1016/S0257-8972(01)01521-3 ↗
26. Investigation of hydroxyapatite (HAP) containing coating on grade 2 titanium alloy prepared by plasma electrolytic oxidation (PEO) at low voltage
27. Correlations between the growth mechanism and properties of micro-arc oxidation coatings on titanium alloy: effects of electrolytes10.1016/j.surfcoat.2017.03.021 ↗
28. In-vitro biocompatibility, antibacterial activity, and corrosion resistance of HA-TiO2/ZnO coating fabricated by plasma electrolytic oxidation on Ti6Al4V10.1016/j.mtcomm.2024.109443 ↗
29. β-Ta2O5 thin film for implant surface modification triggers superior anti-corrosion performance and cytocompatibility of titanium10.1016/j.apsusc.2020.146326 ↗
30. In vitro biocompatibility of a nanocrystalline β-Ta2O5 coating for orthopaedic implants10.1016/j.ceramint.2017.12.040 ↗
31. Effects of surface roughening and calcite coating of titanium on cell growth and differentiation10.1177/0885328219883765 ↗
32. Enhanced bioactivity of 316L stainless steel with deposition of polypyrrole/hydroxyapatite layered hybrid coating: orthopedic applications
33. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
34. Enhanced corrosion protection of NiTi orthopedic implants by highly crystalline hydroxyapatite deposited by spin coating: the importance of pre-treatment10.1016/j.matchemphys.2020.124041 ↗
35. Microstructure characteristic of ceramic coatings fabricated on magnesium alloys by micro-arc oxidation in alkaline silicate solutions10.1016/j.apsusc.2005.09.067 ↗
36. Role of electrolyte chemistry on electronic and in vitro electrochemical properties of micro-arc oxidized titania films on Cp Ti10.1016/j.electacta.2013.05.032 ↗
37. Surface characterization and corrosion behavior of calcium phosphate (Ca-P) base composite layer on Mg and its alloys using plasma electrolytic oxidation (PEO): a review10.1016/j.jma.2020.07.004 ↗
38. Impressive strides in antibacterial performance amelioration of Ti-based implants via plasma electrolytic oxidation (PEO): a review of the recent advancements10.1016/j.cej.2022.136003 ↗
39. Discovery of Al2O3 particles incorporation mechanism in plasma electrolytic oxidation of AM60B magnesium alloy10.1016/j.matlet.2012.07.032 ↗
40. Preparation of ceramic coating on Ti substrate by plasma electrolytic oxidation in different electrolytes and evaluation of its corrosion resistance: Part II10.1016/j.apsusc.2011.10.064 ↗
41. Methods of determining the degree of crystallinity of polymers with X-ray diffraction: a review10.1007/s10965-023-03744-0 ↗
42. Tailoring zirconia surface topography via femtosecond laser-induced nanoscale features: effects on osteoblast cells and antibacterial properties10.1088/1748-605X/ad606f ↗
43. Adhesion evaluation of different bioceramic coatings on Mg–Ca alloys for biomedical applications10.1080/01694243.2016.1171569 ↗
44. RF-magnetron sputter deposited hydroxyapatite-based composite & multilayer coatings: a systematic review from mechanical, corrosion, and biological points of view10.1016/j.ceramint.2020.09.274 ↗
45. Pieniak D, Walczak A, Walczak M, Przystupa K, Niewczas AM. Hardness and wear resistance of dental biomedical nanomaterials in a humid environment with non-stationary temperatures.Materials; 13(5):1255.10.3390/ma13051255 ↗
46. Effects of electrolyte concentration on the microstructure and properties of plasma electrolytic oxidation coatings on Ti-6Al-4V alloy10.1016/j.surfcoat.2019.07.053 ↗
47. Effects of ultrasonic treatment and current density on the properties of hydroxyapatite coating via electrodeposition and its in vitro biomineralization behavior10.1016/j.msec.2019.110062 ↗
48. Controlling the electrodeposition, morphology and structure of hydroxyapatite coating on 316L stainless steel10.1016/j.msec.2013.01.018 ↗
49. Corrosion, wear, and antibacterial behaviors of hydroxyapatite/MgO composite PEO coatings on AZ31 Mg alloy by incorporation of TiO2 nanoparticles10.3390/coatings12121967 ↗
50. Physicochemical and biological characterization of Ti6Al4V particles obtained by implantoplasty: an in vitro study. Part I10.3390/ma14216507 ↗
51. Influence of Ag/Ca ratio on the osteoblast growth and antibacterial activity of TiN coatings on Ti-6Al-4V by Ag and Ca ion implantation10.1016/j.surfcoat.2020.126415 ↗
52. In vitro corrosion performance of PEO coated Ti and Ti6Al4V used for dental and orthopaedic implants10.1016/j.surfcoat.2016.08.018 ↗
53. Rydzynski · 2001 · 511