In vitro degradation and corrosion evaluations of plasma electrolytic oxidized Mg–Zn–Ca–Si alloys for biomedical applications
Source abstract
Abstract
Biodegradable calcium phosphate (CaP) ceramic coatings were prepared on self-designed Mg-2.0Zn-0.6Ca-xSi alloys by plasma electrolytic oxidation (PEO). The effect of calcium (Ca) and silicon (Si) on alloy microstructure and coating formation and biomineralization mechanisms were discussed. The in vitro bioactivity and degradability of CaP coatings were evaluated by immersion tests in simulated body fluid (SBF) solutions and trishydroxymethyl-aminomethane hydrochloric acid (Tris-HCl) buffer, respectively. The microstructure and chemical composition of the coatings, depositions and corrosion products were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray diffractometer (XRD), X-ray photoelectron spectrometer (XPS) and fourier transform infrared spectrometer (FT-IR). The electrochemical corrosion behavior of alloys and coatings was investigated using the electrochemical workstation. Results showed that the shape, quantity, size and distribution of second phases can be changed by the simultaneously addition of Ca and Si in Mg–Zn–Ca–Si alloys. The Si content in Mg-2.0Zn-0.6Ca-xSi alloy should not be higher than 0.8 wt%. The microstructure of Mg-2.0Zn-0.6Ca-xSi alloys can influence the formation and growth of PEO coating by altering the spark discharge characteristics. The plasma electrolytic oxidized Mg-2.0Zn-0.6Ca-0.8Si has potential to be served as biodegradable bone implant and cardiovascular stent.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Bone Tissue Engineering Materials · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Multilayered coating on titanium for controlled release of antimicrobial peptides for the prevention of implant-associated infections10.1016/j.biomaterials.2013.04.036 ↗
2. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
3. In vivo corrosion of four magnesium alloys and the associated bone response10.1016/j.biomaterials.2004.09.049 ↗
4. Improvement of the balance between a reduced stress shielding and bone ingrowth by bioactive coatings onto porous titanium substrates10.1016/j.surfcoat.2018.01.019 ↗
5. Stiffness and strength tailoring of cobalt chromium graded cellular structures for stress-shielding reduction10.1016/j.matdes.2016.11.090 ↗
6. Recent progress in in vivo studies and clinical applications of magnesium based biodegradable implants-A review10.1016/j.jma.2020.11.001 ↗
7. Enhanced antimicrobial properties, cytocompatibility, and corrosion resistance of plasma-modified biodegradable magnesium alloys10.1016/j.actbio.2013.10.012 ↗
8. Effectiveness and safety of biodegradable Mg-Nd-Zn-Zr alloy screws for the treatment of medial malleolar fractures10.1016/j.jot.2020.11.007 ↗
9. Electrophoretic deposition of bioadaptive drug delivery coatings on magnesium alloy for bone repair10.1021/acsami.9b01227 ↗
10. Magnesium-pretreated periosteum for promoting bone-tendon healing after anterior cruciate ligament reconstruction10.1016/j.biomaterials.2020.120576 ↗
11. Degradable biomaterials based on magnesium corrosion10.1016/j.cossms.2009.04.001 ↗
12. Improving the corrosion resistance of ZEK100 magnesium alloy by combining high-pressure torsion technology with hydroxyapatite coating10.1016/j.matdes.2019.107933 ↗
13. In vitro responses of human bone marrow stromal cells to a fluoridated hydroxyapatite coated biodegradable Mg-Zn alloy10.1016/j.biomaterials.2010.04.023 ↗
14. Development of magnesium-based biodegradable metals with dietary trace element germanium as orthopaedic implant applications10.1016/j.actbio.2017.10.004 ↗
15. The influence of biodegradable magnesium implants on the growth plate10.1016/j.actbio.2017.11.031 ↗
16. Biological responses and mechanisms of human bone marrow mesenchymal stem cells to Zn and Mg biomaterials10.1021/acsami.7b06654 ↗
17. Corrosion and erosion properties of silicate and phosphate coatings on magnesium10.1016/j.tsf.2004.06.168 ↗
18. Anodic processes in plasma electrolytic oxidation of aluminium in alkaline solutions10.1016/j.electacta.2003.11.027 ↗
19. Effects of phosphates on microstructure and bioactivity of micro-arc oxidized calcium phosphate coatings on Mg-Zn-Zr magnesium alloy10.1016/j.colsurfb.2013.03.026 ↗
20. Effect of electrical parameters on morphology, chemical composition, and photoactivity of the nano-porous titania layers synthesized by pulse-microarc oxidation10.1016/j.electacta.2009.12.043 ↗
21. Research progress on surface protective coatings of biomedical degradable magnesium alloys10.1016/j.jallcom.2021.161001 ↗
22. In vitro corrosion of micro-arc oxidation coating on Mg-1Li-1Ca alloy-The influence of intermetallic compound Mg2Ca10.1016/j.jallcom.2018.06.073 ↗
23. Superior corrosion protection and adhesion strength of epoxy coating applied on AZ31 magnesium alloy pre-treated by PEO/Silane with inorganic and organic corrosion inhibitors
24. Investigation of hydroxyapatite (HAP) containing coating on grade 2 titanium alloy prepared by plasma electrolytic oxidation (PEO) at low voltage
25. Microstructural and corrosion properties of hydroxyapatite containing PEO coating produced on AZ31 Mg alloy10.3390/ma14061531 ↗
26. A review of the effects of dietary silicon intake on bone homeostasis and regeneration10.1007/s12603-014-0555-8 ↗
27. Microstructure and degradation performance of biodegradable Mg-Si-Sr implant alloys10.1016/j.msec.2016.09.056 ↗
28. In vitro degradation and electrochemical corrosion evaluations of microarc oxidized pure Mg, Mg-Ca and Mg-Ca-Zn alloys for biomedical applications10.1016/j.msec.2014.11.048 ↗
29. 2004
30. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W10.1002/jbm.820240607 ↗
31. Electrochemical polarization I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
32. Manganese, molybdenum, boron, silicon, and other trace elements
33. Direct observation of Dirac cone in multilayer silicene intercalation compound CaSi210.1002/adma.201403077 ↗