journal article·2025-07Open access

The microstructure-mechanical property relationships in Ti–Cu alloys for biomedical applications: A review

Homayoun Mousa Mirabad, Mohammad Reza Akbarpour, Farid Gazani, Amirhossein Ahmadi Chadegani, Iman Khezri, Ali Mirzamohammad, Helia Damghani, Omid Elahi, Mehran Nezakati Khameneh, Hyoung Seop Kim

Abstract

In this extensive review, the role of titanium-copper (Ti–Cu) alloys in the biomedical sector is thoroughly examined especially for microstructural and mechanical properties useful to implant applications. Current processing methodologies, from powder metallurgy to additive manufacturing , demonstrates the process-dependent microstructural outcomes. The diversely derived microstructures are important for the mechanical resilience of Ti–Cu alloys under simulated physiological stresses. Analyses on whether these biomaterials could meet rigorous biomechanical requisites in load-bearing capacities, present both challenges and promising future exploration. This review shows the promise of optimized Ti–Cu alloy, fine-tuned by advanced manufacturing technologies aided by computational modeling. The pivotal aim of most metallic implants is to combine biomechanical compatibility and functional longevity in human tissues, ensuring a balance between biological integration and mechanical reliability.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Aluminum Alloys Composites Properties · Advanced Welding Techniques Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Nb-content-dependent passivation behavior of Ti–Nb alloys for biomedical applications10.1016/j.jmrt.2023.11.203 ↗
2. Towards load-bearing biomedical titanium-based alloys: from essential requirements to future developments10.1016/j.pmatsci.2024.101277 ↗
3. Improving corrosion and wear resistance of 316L stainless steel via in situ pure Ti and Ti6Al4V coatings: tribocorrosion and electrochemical analysis10.3390/ma18030553 ↗
4. Wear and corrosion behaviour of Ti-based coating on biomedical implants10.1080/02670844.2020.1730058 ↗
5. Effect of hot-rolling process on the microstructure, mechanical and corrosion behaviors of dual-phase Co-based entropic alloys10.1016/j.msea.2024.147433 ↗
6. Biodegradable magnesium alloys for orthopaedic applications
7. Alloying design of biodegradable zinc as promising bone implants for load-bearing applications10.1038/s41467-019-14153-7 ↗
8. Biomedical applications of titanium alloys: a comprehensive review10.3390/ma17010114 ↗
9. Biomedical titanium alloys with Young's moduli close to that of cortical bone10.1093/rb/rbw016 ↗
10. Titanium nanostructures for biomedical applications10.1088/0957-4484/26/6/062002 ↗
11. Effect of electropulsing treatment on the microstructure and mechanical properties of Ti6Al4V alloy processed by a hybrid method of directed energy deposition and layer-by-layer ultrasonic impact peening10.1016/j.msea.2024.146774 ↗
12. Biocompatible titanium alloys used in medical applications10.37358/RC.19.4.7114 ↗
13. A review on biomedical titanium alloys: recent progress and prospect10.1002/adem.201801215 ↗
14. Antibacterial Ti-Cu alloy with enhanced mechanical properties as implant applications10.1088/2053-1591/abc371 ↗
15. A new antibacterial titanium–copper sintered alloy: preparation and antibacterial property10.1016/j.msec.2013.06.016 ↗
16. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
17. Antibacterial activities of copper, silver, and zinc-derived nanoparticles and their capacity to enhance the antimicrobial activities of antibiotics10.2174/0115734137301010240507101533 ↗
18. Microstructural evolution during sintering and fracture behavior of iron-copper-carbon compacts made with elemental powders10.1520/MPC20190193 ↗
19. Antibacterial Ti-Mn-Cu alloys for biomedical applications10.1093/rb/rbaa050 ↗
20. In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application10.1016/j.dental.2018.04.007 ↗
21. Properties of experimental titanium‐silver‐copper alloys for dental applications10.1002/jbm.b.31305 ↗
22. Titanium and titanium alloys as dental materials
23. The physical metallurgy of titanium alloys10.1016/0502-8205(58)90004-2 ↗
24. Low-cost powder metallurgy Ti-Cu alloys as a potential antibacterial material10.1016/j.jmbbm.2019.04.004 ↗
25. Investigation of forging formability, microstructures and mechanical properties of pre-hardening Al-Zn-Mg-Cu alloy10.1016/j.jmapro.2024.10.004 ↗
26. In-situ Ti-TiB metal–matrix composite prepared by a reactive pressing process10.1016/S1359-6462(99)00354-1 ↗
27. Microstructural and mechanical characteristics of in situ metal matrix composites10.1016/S0927-796X(00)00024-3 ↗
28. Creep rupture life of in situ synthesized (TiB+TiC)/Ti matrix composites10.1016/S1359-6462(01)00926-5 ↗
29. Mechanical properties of Ti-6Al-4V/TiB composites with randomly oriented and aligned TiB reinforcements10.1016/S1359-6454(02)00510-4 ↗
30. Effect of B4C particle size on microstructure of in situ titanium matrix composites prepared by reactive processing of Ti–B4C system10.1016/j.scriptamat.2006.05.024 ↗
31. Processing-structure-property aspects of particulate-and whisker-reinforced titanium matrix composites10.1016/j.compscitech.2007.07.016 ↗
32. Biomedical materials: a review of titanium based alloys10.1177/0954406220967694 ↗
33. Processing and microstructure of Ti-Cu binary alloys: a comprehensive review10.1016/j.pmatsci.2022.100933 ↗
34. A brief review on the properties of titanium as a metallic biomaterials
35. Design of near α-Ti alloys with optimized mechanical and corrosion properties and their characterizations10.3390/met14010081 ↗
36. Effect of cooling rate on Ti–Cu eutectoid alloy microstructure10.1016/j.msec.2008.09.007 ↗
37. A review of metastable beta titanium alloys10.3390/met8070506 ↗
38. Structural, electronic, mechanical, and thermodynamic properties of Cu–Ti intermetallic compounds: first-principles calculations10.1016/j.ssc.2022.114814 ↗
39. Intermetallic compound formations in titanium-copper thin-film couples10.1063/1.334422 ↗
40. Towards a better understanding of the phase transformations in explosively welded copper to titanium sheets10.1016/j.msea.2020.139285 ↗
41. Formation of Ti2Cu in Ti-Cu alloys10.1007/s11669-022-00964-7 ↗
42. Mueller · 1963 · 227
43. Cu-Ti (Copper-Titanium)10.1361/105497102770331307 ↗
44. The Cu−Ti (Copper-Titanium) system10.1007/BF02880329 ↗
45. Cu-Ti and Cu-Ti-Al solid state phase equilibria in the Cu-rich region10.1515/ijmr-1983-740809 ↗
46. Constitution of binary alloys10.1149/1.2428700 ↗
47. X-ray diffraction for phase identification in Ti-based alloys: benefits and limitations10.1088/1402-4896/ad4785 ↗
48. Structural studies on Ti–Cu alloy obtained by high-energy ball milling10.1080/02670836.2019.1596584 ↗
49. Characterization and hardness of TiCu–Ti 2 Cu 3 intermetallic material fabricated by mechanical alloying and subsequent annealing10.1088/2053-1591/3/4/045004 ↗
50. Microstructure and mechanical properties of sintered Ti-Cu alloys10.4028/www.scientific.net/AMR.93-94.99 ↗
51. Microstructural, electrochemical and tribo-electrochemical characterisation of titanium-copper biomedical alloys10.1016/j.corsci.2016.02.014 ↗
52. Densification and mechanical and antibacterial properties of low-cost powder metallurgy TiCu intermetallic alloy as a potential biomedical material10.1007/s11837-020-04234-0 ↗
53. Biocompatibility, osseointegration, antibacterial and mechanical properties of nanocrystalline Ti-Cu alloy as a new orthopedic material
54. Effect of Cu content on the antibacterial activity of titanium–copper sintered alloys10.1016/j.msec.2013.11.028 ↗
55. Effect of extrusion processing on the microstructure, mechanical properties, biocorrosion properties and antibacterial properties of Ti-Cu sintered alloys10.1016/j.msec.2016.07.051 ↗
56. Microstructure, mechanical properties, and sliding wear behavior of spark plasma sintered Ti-Cu alloys10.1007/s11661-018-4953-0 ↗
57. Copper release and ROS in antibacterial activity of Ti-Cu alloys against implant-associated infection10.1007/s12598-022-02242-4 ↗
58. The high-quality precision casting of titanium alloys10.1007/s11837-998-0409-0 ↗
59. Equi-axed growth and related segregations in cast metallic alloys10.1016/S1468-6996(01)00055-9 ↗
60. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti–Cu alloys10.1088/1748-6041/11/6/065001 ↗
61. Effects of composition and heat treatment on the mechanical behavior of Ti–Cu alloys10.1016/j.matdes.2013.10.050 ↗
62. The role of Cu-based intermetallics on the pitting corrosion behavior of Sn–Cu, Ti–Cu and Al–Cu alloys10.1016/j.electacta.2012.05.106 ↗
63. On the decomposition of β phase in some rapidly quenched titanium-eutectoid alloys10.1007/BF02647587 ↗
64. Corrosion characteristics of .ALPHA.-Ti and Ti2Cu composing Ti-Cu alloys10.4012/dmj.24.610 ↗
65. Solidification structure and segregation in cast ingots of titanium alloy produced by vacuum arc consumable electrode method10.2355/isijinternational.31.775 ↗
66. Influence of mold design on shrinkage porosity of Ti-6Al-4V alloy ingots10.3390/met12122122 ↗
67. Effect of cooling rate on solidification microstructure and mechanical properties of TiB2-containing TiAl alloy10.1016/S1003-6326(21)65504-8 ↗
68. Effect of Cu content on the precipitation behaviors, mechanical and corrosion properties of as-cast Ti-Cu alloys10.3390/ma15051696 ↗
69. Effects of cooling rate on the microstructure and solute partitioning in near eutectoid Ti–Cu alloys10.1080/14786435.2014.913113 ↗
70. Donthula · 2021 · 97
71. Microstructure and mechanical behavior of Ti—Cu alloys produced by semisolid processing10.1016/S1003-6326(22)66040-0 ↗
72. Morphological evolution of transformation products and eutectoid transformation(s) in a hyper-eutectoid Ti-12 at% Cu alloy10.1016/j.actamat.2019.01.044 ↗
73. Mechanical properties and microstructures of cast Ti–Cu alloys10.1016/S0109-5641(02)00027-1 ↗
74. Electrochemical behavior of centrifuged cast and heat treated Ti–Cu alloys for medical applications10.1016/j.electacta.2009.09.016 ↗
75. Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications
76. Laser powder bed fusion in-situ alloying of Ti-5%Cu alloy: process-structure relationships10.1016/j.jallcom.2020.157558 ↗
77. Antibacterial copper-bearing titanium alloy prepared by laser powder bed fusion for superior mechanical performance10.1016/j.jmst.2022.04.056 ↗
78. Review on volumetric energy density: influence on morphology and mechanical properties of Ti6Al4V manufactured via laser powder bed fusion10.1007/s40964-022-00328-0 ↗
79. On the effect of volumetric energy density on the characteristics of 3D-printed metals and alloys10.3390/met13101776 ↗
80. Microstructural evolution of Ti–2.5Cu alloys produced by powder metallurgy and laser powder bed fusion10.1007/s11661-025-07709-4 ↗
81. Improved corrosion resistance of selective laser melted Ti–5Cu alloy using atomized Ti–5Cu powder10.1007/s40195-019-00896-1 ↗
82. Evolution of solidification texture during additive manufacturing10.1038/srep16446 ↗
83. Corrosion and antibacterial performance of novel selective-laser-melted (SLMed) Ti-xCu biomedical alloys10.1016/j.jallcom.2020.158415 ↗
84. Graphene oxide reinforced iron matrix composite with enhanced biodegradation rate prepared by selective laser melting10.1002/adem.201900314 ↗
85. Study on Fe-xGO composites prepared by selective laser melting: microstructure, hardness, biodegradation and cytocompatibility10.1007/s11837-019-03814-z ↗
86. Influence of copper on the microstructure and mechanical properties of titanium ortho-alloy produced by selective laser melting10.17073/1997-308X-2024-1-31-39 ↗
87. Microstructural characteristic and mechanical properties of titanium-copper alloys in-situ fabricated by selective laser melting10.1016/j.jallcom.2021.161032 ↗
88. Improved corrosion resistance on selective laser melting produced Ti-5Cu alloy after heat treatment10.1021/acsbiomaterials.8b00319 ↗
89. Advances in additively manufactured titanium alloys by powder bed fusion and directed energy deposition: microstructure, defects, and mechanical behavior10.1016/j.jmst.2023.11.003 ↗
90. Microstructure and tribological properties of Ti–Cu intermetallic compound coating10.1016/j.matdes.2011.10.033 ↗
91. Influence of Cu addition on the microstructure and tribological properties of Ti-based laser cladded composite coatings on TC4
92. Influence of Cu on microstructure and wear resistance of TiC/TiB/TiN reinforced composite coating fabricated by laser cladding10.1016/j.matchemphys.2012.01.082 ↗
93. Additive manufacturing of ultrafine-grained high-strength titanium alloys10.1038/s41586-019-1783-1 ↗
94. Effect of layer thickness setting on deposition characteristics in direct energy deposition (DED) process10.1016/j.optlastec.2016.07.001 ↗
95. On the texture formation of selective laser melted Ti-6Al-4V10.1007/s11661-014-2218-0 ↗
96. Excellent synergies of mechanical properties and biological performance of additively-manufactured TiCu alloy10.1016/j.matchar.2024.114255 ↗
97. Insights into nano-ZrO2 reinforced self-antibacterial Ti–3Cu composites via laser metal deposition: content-optimized bioactive nano-ZrO2 integrated for wear resistance, in vitro antibacterial and biological properties10.1039/D5TB00143A ↗
98. On the selection of Ti–Cu alloys for thixoforming processes: phase diagram and microstructural evaluation10.1007/s10853-015-9367-4 ↗
99. Observations on the compression properties of semisolid Ti–Cu alloys10.1016/j.jmrt.2020.11.014 ↗
100. In-situ microstructural observation of Ti-Cu alloys for semi-solid processing10.1016/j.matchar.2018.08.016 ↗