Effect of Cu-bearing precipitates on mechanical, wear and antibacterial properties of Ti–Nb–Zr–Cu alloy
Source abstract
Abstract
The Cu addition could affect mechanical, wear and antibacterial properties of Ti–Nb–Zr alloy due to the Cu-bearing precipitates. In this work, the precipitation type, morphology and distribution of Cu-bearing precipitates in the Ti–35Nb–7Zr–10Cu alloy were controlled via heat treatment at 800, 850, 900, 950 and 1000 °C followed by water cooling. The effects of Cu-bearing precipitates on the mechanical, wear, and antibacterial properties of Ti–Nb–Zr–Cu alloy were investigated. Results showed that the main Cu-bearing precipitates were composed of Ti 2 Cu and Cu 8 Zr 3 phases. With the increase of heat temperature, the Ti 2 Cu phase decreased while the Cu 8 Zr 3 phase increased. The morphology of Cu-bearing precipitates changed from network to spherical. The HT1000 sample had the lowest elastic modulus of 46 ± 1 GPa, close to that of human bone. However, with increased heat temperature, the yield strength of samples HT950 and HT1000 displayed higher values of 900–1319 MPa, while the hardness increased from 353 ± 10 to 510 ± 25 HV. The elastic strain energy of samples HT950 and HT1000 were also higher in the range of 17.85 and 31.63 MJ/m 3 . The friction coefficient and 3D morphology were used to characterize the wear properties. Sample HT1000 exhibited the minimum wear depth and COF. However, the Ti–35Nb–7Zr–10Cu alloy exhibited weak antibacterial properties against E. coli because the Cu ion concentrations of the alloy were lower than the minimum inhibitory concentration for E. coli . The precipitation type, morphology and distribution of Cu-bearing precipitation significantly affected the mechanical, wear and antibacterial properties of the Ti–Nb–Zr–Cu alloy.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Advanced materials and composites · Intermetallics and Advanced Alloy Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Osseointegration behavior of novel Ti-Nb-Zr-Ta-Si alloy for dental implants: an in vivo study10.1007/s10856-016-5755-9 ↗
2. New developments of Ti-based alloys for biomedical applications10.3390/ma7031709 ↗
3. Antibacterial effects and biocompatibility of titanium surfaces with graded silver incorporation in titania nanotubes10.1016/j.biomaterials.2014.02.005 ↗
4. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
5. Ta-coated titanium surface with superior bacteriostasis and osseointegration10.2147/IJN.S218640 ↗
6. Enhanced antibacterial activity of curcumin by combination with metal ions10.1016/j.colcom.2018.04.009 ↗
7. Antibacterial titanium surfaces for medical implants10.1016/j.msec.2015.12.062 ↗
8. Modification of TiAlV alloys with hybrid layers containing metallic nanoparticles obtained by the sol-gel method: surface and structural properties10.3390/ijms23042283 ↗
9. Characteristics of novel Ti-10Mo-xCu alloy by powder metallurgy for potential biomedical implant applications
10. Influence of Cu, Au and Ag on structural and surface properties of bioactive coatings based on titanium10.1016/j.msec.2016.11.091 ↗
11. Physicochemical and antibacterial characterization of ionocity Ag/Cu powder nanoparticles10.1016/j.matchar.2016.04.013 ↗
12. Spontaneous immunomodulation and regulation of angiogenesis and osteogenesis by Sr/Cu-borosilicate glass (BSG) bone cement to repair critical bone defects
13. Transplantation of copper-doped calcium polyphosphate scaffolds combined with copper (II) preconditioned bone marrow mesenchymal stem cells for bone defect repair10.1177/0885328217739456 ↗
14. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of wrought Ti-3Cu alloy by heat treatment
15. Production and mechanical properties of Ti-5Al-2.5Fe-xCu alloys for biomedical applications
16. Towards bone-like elastic modulus in TiNbSn alloys with large recovery strain for biomedical applications10.1016/j.jallcom.2022.166724 ↗
17. Microstructure evolution, electrochemical properties and in-vitro properties of Ti-Nb-Zr based biocomposite by hydroxyapatite bioceramic10.1016/j.jallcom.2018.06.132 ↗
18. Effects of composition and heat treatment on the mechanical behavior of Ti–Cu alloys10.1016/j.matdes.2013.10.050 ↗
19. Synthesis, characterization and antimicrobial studies of Ti-40Nb-10Ag implant biomaterials10.3390/met12081391 ↗
20. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
21. Antibacterial Ti-35Nb-7Zr-xCu alloy with excellent mechanical properties generated with a spark plasma sintering method for biological applications10.1016/j.jallcom.2021.160473 ↗
22. Mechanical, corrosion and antibacterial properties of Ti-13Nb-13Zr-based alloys with various Cu contents10.1088/2053-1591/ac2f74 ↗
23. A review on alloy design, biological response, and strengthening of β-titanium alloys as biomaterials10.1016/j.msec.2020.111661 ↗
24. Formation of Ti2Cu in Ti-Cu alloys10.1007/s11669-022-00964-7 ↗
25. The L-G phase transition in binary Cu-Zr metallic liquids10.1039/D1CP04157F ↗
26. Microstructure and mechanical properties of Ti-35Nb-2Ta-3Zr alloy by laser quenching10.3389/fmats.2019.00318 ↗
27. The influence of copper content on the elastic modulus and antibacterial properties of Ti-13Nb-13Zr-xCu alloy10.3390/met12071132 ↗
28. Rapid quenching of semisolid Ti-Cu alloys: insights into globular microstructure formation and coarsening10.1016/j.actamat.2017.08.006 ↗
29. Effect of Ti2Cu precipitates on mechanical behavior of Ti-2.5Cu alloy subjected to different heat treatments10.1016/j.jallcom.2009.04.095 ↗
30. Superelasticity over a wide temperature range in metastable β-Ti shape memory alloys10.1016/j.jallcom.2020.157090 ↗
31. Grindability of cast Ti-Cu alloys10.1016/S0109-5641(02)00080-5 ↗
32. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of wrought Ti-3Cu alloy by heat treatment
33. In situ growth of self-organized Cu-containing nano-tubes and nano-pores on Ti90−xCu10Alx (x=0, 45) alloys by one-pot anodization and evaluation of their antimicrobial activity and cytotoxicity10.1016/j.surfcoat.2013.12.036 ↗
34. Optimization of mechanical property, antibacterial property and corrosion resistance of Ti-Cu alloy for dental implant10.1016/j.jmst.2019.03.044 ↗
35. Low-cost powder metallurgy Ti-Cu alloys as a potential antibacterial material10.1016/j.jmbbm.2019.04.004 ↗
36. A novel biomedical titanium alloy with high antibacterial property and low elastic modulus10.1016/j.jmst.2021.01.015 ↗
37. Characterization of a new Ti-13Nb-13Zr-10Cu alloy with enhanced antibacterial activity for biomedical applications10.1016/j.matlet.2019.07.008 ↗
38. Strain energy evolution analysis of elastic-plastic deformation on polycarbonate by infrared radiation characteristics, Nondestruct. Test
39. Characterization on corrosion and antibacterial properties of a new functionally graded porous Ti-Mo-Cu alloys with improved cytocompatibility10.1016/j.vacuum.2023.112353 ↗
40. High-strength β stabilized Ti-Nb-Fe-Cr alloys with large plasticity10.1016/j.msea.2018.07.031 ↗
41. Mechanical and corrosion-resistant properties of Ti-Nb-Si-N nanocomposite films prepared by a double glow discharge plasma technique10.1016/j.ceramint.2014.01.079 ↗
42. Improvement of in vitro corrosion, wear, and mechanical properties of newly developed Ti alloy by thermal treatment for dental applications10.1016/S1003-6326(21)65552-8 ↗
43. Effect of annealing temperature on mechanical and antibacterial properties of Cu-bearing titanium alloy and its preliminary study of antibacterial mechanism10.1016/j.msec.2018.08.018 ↗
44. Microstructural characterization and antibacterial activity of carbon nanotube decorated with Cu nanoparticles synthesized by a novel solvothermal method10.1016/j.ceramint.2021.05.299 ↗
45. Enhancement in mechanical properties, antimicrobial properties and osseointegration ability of porous TC4-5Cu alloys prepared via additive manufacturing10.1016/j.jmrt.2024.02.007 ↗
46. Antibacterial effect of copper-bearing titanium alloy (Ti-Cu) against Streptococcus mutans and Porphyromonas gingivalis
47. Novel function-structure-integrated Ti-Mo-Cu alloy combined with excellent antibacterial properties and mechanical compatibility as implant application10.1016/j.jallcom.2023.169323 ↗