Corrosion behaviour of sintered Ti–Ni–Cu–Nb in 0.9% NaCl environment
Source abstract
Abstract
The uniform and localized corrosion behaviour of sintered Ti–Ni containing niobium and copper additions were studied using potentiodynamic and cyclic polarization measurements in 0.9% sodium chloride. Results indicated that copper and niobium addition did not have significant effects on the uniform corrosion characteristics, but significantly improved the pitting corrosion resistance. Both copper and niobium additions significantly increased the re-passivation potentials, while copper was observed to reduce the pitting hysteresis loop area. Alloys containing 15% copper and 2% niobium additions depicted the most improved pitting corrosion resistance, and increased the re-passivation value from −315.60 mV to a high re-passivation potential of 840.68 mV.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties · Intermetallics and Advanced Alloy Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Physical metallurgy of Ti–Ni-based shape memory alloys10.1016/j.pmatsci.2004.10.001 ↗
2. Properties and heat treatment of high transition temperature Ti–Ni–Hf alloys10.1007/s11665-009-9357-2 ↗
3. Evaluation techniques of metallic biomaterials in vitro10.1016/S1468-6996(02)00028-1 ↗
4. Metal ion release from new and recycled stainless steel brackets10.1093/ejo/26.2.171 ↗
5. Surface structure and corrosion resistance of short-time heat-treated NiTi shape memory alloy10.1016/j.apsusc.2010.08.097 ↗
6. Corrosion performance of HVOF and APS thermally sprayed NiTi intermetallic coatings in 3.5% NaCl solution10.1016/j.corsci.2009.11.034 ↗
7. Effects of Cl− ion concentration and pH on the corrosion properties of NiTi alloy in NaCl solution10.1023/A:1022222631058 ↗
8. Corrosion and passivity of Ti-13% Nb-13% Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
9. Alloying of copper for use in microelectronic metallization10.1016/0254-0584(95)01513-2 ↗
10. Thermal efficiencies of NiTiCu shape memory alloys10.1016/S0040-6031(98)00607-8 ↗
11. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni–Ti alloy also in presence of stress-induced martensite10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P ↗
12. The effect of Cu addition on the hot deformation behavior of NiTi shape memory alloys10.1016/j.jallcom.2010.01.124 ↗
13. The thermal cycling effect on Ti–Ni–Cu shape memory alloy10.1016/0956-716X(95)93219-T ↗
14. An electrochemical study of the crevice corrosion resistance of NiTi in Hanks’ solution10.1016/j.jallcom.2006.07.127 ↗
15. The estimation of corrosion behavior of NiTi and NiTiNb alloys using dynamic electrochemical impedance spectroscopy
16. Corrosion behavior of a low modulus β-Ti-45%Nb alloy for use in medical implants10.1007/s10856-006-6330-6 ↗
17. Surface characteristics: nano-indentation and corrosion behavior of Nb implanted NiTi alloy10.1016/j.surfcoat.2011.03.061 ↗
18. Electrochemical and histomorphometric evaluation of the Ti–NiCu shape memory alloy10.3233/BME-1997-7101 ↗
19. Effect of ternary element addition on the corrosion behaviour of NiTi shape memory alloys
20. Electrochemical characterization of Ni47.7Ti37.8Nb14.5 shape memory alloy in artificial saliva10.1002/maco.201106337 ↗
21. Biomimetic implant coatings10.1016/j.bioeng.2006.05.016 ↗
22. Turbula mixing characteristics of carbide powders and its influence on laser processing of stainless steel composite coatings10.1016/j.powtec.2012.07.025 ↗
23. Synthesis and characterization of sub-micron sized copper–ruthenium–tantalum composites for interconnection application10.1016/j.microrel.2012.03.020 ↗
24. Effect of copper on the localized corrosion resistance of Ni–Ti shape memory alloy10.1016/S0142-9612(01)00142-9 ↗
25. High temperature oxidation behavior of NiTiNb intermetallic alloys10.1016/j.intermet.2007.01.005 ↗
26. Electrochemical corrosion behaviour of Ti44Ni47Nb9 alloy in simulated body fluid10.1016/j.msea.2006.02.185 ↗