Investigation of wear of ultra high molecular weight polyethylene in a soft tissue behaviour knee joint prosthesis wear test simulator
Source abstract
Abstract
Knee joint prostheses are commonly employed for therapy in over-use disorder, and as a result of traffic accident and sports injuries. However, errors that can occur due to their use need to be defined. In order to determine the types and rates of wear that might occur in prosthetic components, wear tests were performed in knee joint simulators that mimiced knee joint motion. In this study, the wear was specifically examined in ultra high molecular weight polyethylene (UHMWPE) insert material in the four-axis knee joint prosthesis wear test simulator, and the causes for it were examined. Wear tests were performed for 3 different cycles, 1 × 106, 2 × 106 and 3 × 106. Following wear tests, microscopic images, and mass loss and surface roughness measurements were taken from the UHMWPE insert condyle surface. With an increase in the number of cycles, pitting wear, scratches, agglomerated particles and delamination were seen more clearly on the UHMWPE material surface, due to repetitive forces on different axes. In addition, surface roughness measurements taken from worn surfaces increased the with the number of cycles, and flexion/extension (F/E) motion range increased with surface roughness. Wear rates in the medial region of the UHMWPE insert were higher than in the lateral region.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Analysis of wear and friction of total knee replacements: Part I. Wear assessment on a three station wear simulator10.1016/j.wear.2008.02.024 ↗
2. Shı · 2007
3. Romeo · 2015
4. Campbell · 2008
5. Quadriceps force during knee extension in different replacement scenarios with a modular partial prosthesis10.1016/j.clinbiomech.2013.11.007 ↗
6. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing10.1016/j.jbiomech.2015.09.007 ↗
7. Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator10.1016/j.jbiomech.2015.07.043 ↗
8. Kinematic differences in posterior stabilized total knees determined by a holistic experimental evaluation method10.1115/1.4024506 ↗
9. Differences in wear between load and displacement control tested total knee replacements10.1016/j.wear.2009.01.028 ↗
10. Wear performance of 1900 direct compression molded, 1020 direct compression molded, and 1020 sheet compression molded UHMWPE under knee simulator testing10.1016/j.wear.2007.01.120 ↗
11. ISO · 2014
12. ISO · 2009
13. Polyethylene wear is influenced by manufacturing technique in modular TKA10.1007/s11999-008-0470-6 ↗
14. What design factors influence wear behavior in total knee replacement?
15. Mechanical, anatomical, and kinematic axis in TKA: concepts and practical applications10.1007/s12178-014-9218-y ↗
16. Analysis of wear and friction of total knee replacements10.1016/j.wear.2008.02.024 ↗
17. Effect of joint laxity on polyethylene wear in total knee replacement10.1016/j.jbiomech.2009.12.016 ↗
18. Computational wear prediction of artificial knee joints based on a new wear law and formulation10.1016/j.jbiomech.2011.01.027 ↗
19. The study of granular agglomeration mechanism10.1016/j.powtec.2010.01.016 ↗
20. The biological response to nanometre-sized polymer particles10.1016/j.actbio.2015.05.016 ↗
21. Understanding deposition mechanism in cold sprayed ultra high molecular weight polyethylene coatings on metals by isolated particle deposition method10.1016/j.addma.2018.02.022 ↗
22. Rawal · 2016 · 60
23. A patient-specific wear prediction framework for an artificial knee joint with coupled musculoskeletal multibody-dynamics and finite element analysis10.1016/j.triboint.2016.10.050 ↗
24. Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations10.1016/S0021-9290(03)00255-0 ↗