journal article·1997

OPTIMIZATION OF A PLAIN-JET AIRBLAST ATOMIZER

Eran Sher, Ronen Harari

Atomization and Sprays· Volume 7· Issue 1
Publisher page

Abstract

The relationship between the geometric proportions of a simple external-mixing plain-jet airblast atomizer and the characteristics of the generated spray pattern has been investigated. The experimental conditions varied in the range of Re = 1236 to 3540, We = 65 to 595, and air/liquid velocity ratio 15 to 110. The minimum Sauter mean diameter was obtained when the axial location of the liquid orifice is such that the air jet impinges the liquid jet at 45° and the exposure length is maximal. The Sauter mean diameter is found to be proportional to (Vf/Va)0.5 over the entire range of operational conditions (within an error of ±7.5%). The most uniform droplet distribution was obtained when the axial location of the liquid orifice is such that the air jet impinges on the liquid jet at the orifice mouth with an impingement angle of 30°.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fluid Dynamics and Heat Transfer · Plant Surface Properties and Treatments · Electrohydrodynamics and Fluid Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.