journal article·2025-05Open access

Effect of aging treatments on mechanical, chemical, and antibacterial properties of a β-type Ti–Nb–Cu alloy for implant applications

Ludovico Andrea Alberta, Paula Milena Giraldo-Osorno, Avinash Hariharan, Jithin Vishnu, Stefan Pilz, Andrea Voß, Anders Palmquist, Margarita Trobos, Annett Gebert, Mariana Calin

Abstract

Bacterial infections are one major cause of metallic implant failure. A metastable β-type 96(Ti–45Nb)–4Cu alloy was developed for potential load-bearing implant applications with tailored antibacterial properties. The cast alloy was initially subjected to homogenization (1000 °C, 24 h, water-quenched), and then aged at two temperatures (425 °C, 640 °C, 8 h). The influence of aged microstructures on structural (XRD, SEM, APT), mechanical (microhardness, tensile tests), and corrosion (potentiodynamic polarization, ion release) behaviour, as well as on macrophage cytocompatibility and antibacterial properties, was studied. The homogenized microstructure consists of a single-phase β, which partially decomposes into β+ω (aging at 425 °C), and into three phases, β+Ti 2 Cu+α (aging at 640 °C). The ω phase leads to a drastic increase in yield strength ( σ y > 1 GPa), and concomitant decrease in elongation ( ε max = 2 %). The three-phase alloy shows a moderate yield strength ( σ y = 578 MPa), acceptable elongation ( ε max = 10 %), and low Young's modulus ( E = 78 GPa). All three alloys exhibit, in simulated physiological solution, low free corrosion and direct transfer to stable anodic passivity, similar to Ti–6Al–4V. The alloy aged at 425 °C exhibits enhanced corrosion activity in the higher anodic polarization regime due to ω precipitates in the β matrix. The three-phase alloy shows good cytocompatibility with THP-1 macrophages at 24 h. Moreover, it exhibits antibacterial effect against S. aureus at 4 h. In conclusion, the aged alloy containing Ti 2 Cu precipitates exhibits a good combination of properties: high strength and elongation, low Young's modulus, excellent corrosion resistance, good biocompatibility, and antibacterial properties.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Intermetallics and Advanced Alloy Properties · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. Titanium alloys in total joint replacement—a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
2. Is aluminum exposure a risk factor for neurological disorders?10.4103/jrms.JRMS_921_17 ↗
3. Assessment of the genetic risks of a metallic alloy used in medical implants10.1590/S1415-47572010005000118 ↗
4. Problem of stress shielding and improvement to the hip implant designs: a review10.3923/jms.2007.460.467 ↗
5. Composition dependence of Young's modulus in beta titanium binary alloys10.4028/www.scientific.net/MSF.426-432.3103 ↗
6. Microstructural and mechanical properties of β-type Ti–Mo–Nb biomedical alloys with low elastic modulus10.1016/j.jallcom.2019.152412 ↗
7. Elastic softening of β-type Ti-Nb alloys by indium (In) additions10.1016/j.jmbbm.2014.07.010 ↗
8. Effects of Ga on the structural, mechanical and electronic properties of β-Ti-45Nb alloy by experiments and ab initio calculations10.1016/j.jmbbm.2023.105728 ↗
9. Novel low modulus beta-type Ti–Nb alloys by gallium and copper minor additions for antibacterial implant applications10.1016/j.jmrt.2022.08.111 ↗
10. Antimicrobial applications of copper10.1016/j.ijheh.2016.06.003 ↗
11. In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application10.1016/j.dental.2018.04.007 ↗
12. Biocorrosion properties of antibacterial Ti–10Cu sintered alloy in several simulated biological solutions10.1007/s10856-015-5459-6 ↗
13. Enhancement in mechanical properties, antimicrobial properties and osseointegration ability of porous TC4-5Cu alloys prepared via additive manufacturing10.1016/j.jmrt.2024.02.007 ↗
14. Characterization on corrosion and antibacterial properties of a new functionally graded porous Ti–Mo–Cu alloys with improved cytocompatibility10.1016/j.vacuum.2023.112353 ↗
15. Novel function-structure-integrated Ti-Mo-Cu alloy combined with excellent antibacterial properties and mechanical compatibility as implant application10.1016/j.jallcom.2023.169323 ↗
16. Design of a new Ti-Mo-Cu alloy with excellent mechanical and antibacterial properties as implant materials10.1016/j.matlet.2021.130875 ↗
17. Antibacterial Ti–Cu implants: a critical review on mechanisms of action
18. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
19. The effect of copper content on the mechanical and tribological properties of hypo-, hyper- and eutectoid Ti-Cu alloys10.3390/ma13153411 ↗
20. Development of antibacterial Ti-Cux alloys for dental applications: effects of ageing for alloys with up to 10 wt% Cu10.3390/ma12234017 ↗
21. Morphological evolution of transformation products and eutectoid transformation(s) in a hyper-eutectoid Ti-12 at% Cu alloy10.1016/j.actamat.2019.01.044 ↗
22. Ti-6Al-4V-5Cu synthesized for antibacterial effect in vitro and in vivo via contact sterilization10.1016/j.jmst.2021.03.007 ↗
23. Anti-bacterium influenced corrosion effect of antibacterial Ti-3Cu alloy in Staphylococcus aureus suspension for biomedical application10.1016/j.msec.2018.09.057 ↗
24. Antibacterial effect of the controlled nanoscale precipitates obtained by different heat treatment schemes with a Ti-based nanomaterial, Ti–7.5Mo–5Cu alloy10.1021/acsabm.0c00716 ↗
25. Biological corrosion behaviour and antibacterial properties of Ti-Cu alloy with different Ti2Cu morphologies for dental applications10.1016/j.matdes.2022.110540 ↗
26. Thermal stability and phase transformations of martensitic Ti–Nb alloys10.1088/1468-6996/14/5/055004 ↗
27. Tribocorrosion behavior of β-type Ti-Nb-Ga alloys in a physiological solution10.1016/j.triboint.2023.108325 ↗
28. In situ site-specific specimen preparation for atom probe tomography10.1016/j.ultramic.2006.06.008 ↗
29. Influence of isothermal omega precipitation aging on deformation mechanisms and mechanical properties of a β-type Ti-Nb alloy10.1016/j.jallcom.2022.167309 ↗
30. Effect of Cu content on the precipitation behaviors, mechanical and corrosion properties of as-cast Ti-Cu alloys10.3390/ma15051696 ↗
31. Phase transition, microstructural evolution and mechanical properties of Ti-Nb-Fe alloys induced by Fe addition10.1016/j.matdes.2016.02.094 ↗
32. Antibacterial Ti-35Nb-7Zr-xCu alloy with excellent mechanical properties generated with a spark plasma sintering method for biological applications10.1016/j.jallcom.2021.160473 ↗
33. Effect of minor gallium addition on corrosion, passivity, and antibacterial behaviour of novel β-type Ti–Nb alloys10.1016/j.jmrt.2023.06.219 ↗
34. Effect of indium (In) on corrosion and passivity of a beta-type Ti-Nb alloy in Ringer's solution10.1016/j.apsusc.2015.02.058 ↗
35. Corrosion behavior of copper alloys in chloride media10.1016/j.matdes.2008.10.015 ↗
36. Mechanical properties of Ti-Nb-Cu alloys for dental machining applications10.3390/jfb13040263 ↗
37. Effect of Cu addition on shape memory behavior of Ti-18 mol%Nb alloys10.2320/matertrans.48.414 ↗
38. Enhanced work hardening from oxygen-stabilized ω precipitates in an aged metastable β Ti-Nb alloy10.1016/j.actamat.2021.117302 ↗
39. Effects of Nb on superelasticity and low modulus properties of metastable β-type Ti-Nb-Ta-Zr biomedical alloys10.1007/s11665-019-03897-4 ↗
40. Effect of Cu-bearing precipitates on mechanical, wear and antibacterial properties of Ti–Nb–Zr–Cu alloy10.1016/j.jmrt.2024.11.141 ↗
41. Influence of ω phase precipitation on mechanical performance and corrosion resistance of Ti–Nb–Zr alloy10.1016/j.matdes.2016.09.026 ↗
42. Electrochemical behavior of centrifuged cast and heat treated Ti-Cu alloys for medical applications10.1016/j.electacta.2009.09.016 ↗
43. Optimization of mechanical property, antibacterial property and corrosion resistance of Ti-Cu alloy for dental implant10.1016/j.jmst.2019.03.044 ↗
44. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti–Cu alloys10.1088/1748-6041/11/6/065001 ↗
45. Cell membrane damage and protein interaction induced by copper containing nanoparticles-Importance of the metal release process10.1016/j.tox.2013.07.012 ↗
46. Biocompatibility and Cu ions release kinetics of copper-bearing titanium alloys10.1016/j.jmst.2021.03.074 ↗
47. Biomaterials-mediated regulation of macrophage cell fate10.3389/fbioe.2020.609297 ↗
48. Contact killing and antimicrobial properties of copper10.1111/jam.13681 ↗
49. Contact killing of Cu-bearing stainless steel based on charge transfer caused by the microdomain potential difference10.1021/acsami.9b19596 ↗