Surface film characterizations and electrochemical behavior of type I collagen-immobilized interconnected porous Ti–Nb–Zr–Sn alloy scaffolds in simulated inflammatory environment
Source abstract
Abstract
Inflammation in the tissue surrounding titanium (Ti)-based alloy implants can lead to increased acidity and the release of reactive oxygen species (e.g., H2O2), which can undermine the corrosion resistance of surface protective films. This study created 3D-printed interconnected porous Ti–24Nb–4Zr–8Sn (Ti2448) alloy scaffolds, over which was applied alkali treatment followed by type I collagen immobilization via natural cross-linker procyanidin. The samples were characterized in terms of polarization curves, surface film characterizations, and electrochemical impedance spectroscopy analysis under simulated inflammatory (SI) environment (150 mM H2O2-containing simulated body fluid with pH 5.2). The SI environment was shown to compromise the corrosion resistance of untreated Ti2448 scaffolds. The surface-treated samples presented a dense, homogeneous surface film of mainly TiO2 and Nb2O5, which moderated the adverse effects of SI environment. Electrochemical equivalent circuits of the surface-treated Ti2448 scaffolds under SI environment included two resistor-capacitor (RC) circuits, corresponding to a protective inner film and a less protective outer film. This might be the first study which proposed a unique surface treatment to provide a protective surface film over 3D-printed interconnected porous biomedical Ti2448 alloy scaffolds under SI environment.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Improved bioactivity of 3D printed porous titanium alloy scaffold with chitosan/magnesium-calcium silicate composite for orthopaedic applications10.3390/ma12020203 ↗
2. Mesoporous surface topography promotes bone cell differentiation on low elastic modulus Ti-25Nb-25Zr alloys for bone implant applications10.1016/j.jallcom.2016.12.206 ↗
3. Additive manufacturing of titanium alloys by electron beam melting: a review10.1002/adem.201700842 ↗
4. Electron beam melted beta-type Ti-24Nb-4Zr-8Sn porous structures with high strength-to modulus ratio10.1016/j.jmst.2016.03.020 ↗
5. Elastic deformation behaviour of Ti-24Nb–4Zr-7.9 Sn for biomedical applications10.1016/j.actbio.2006.11.002 ↗
6. Enhancing corrosion resistance and biocompatibility of interconnected porous β-type Ti-24Nb-4Zr-8Sn alloy scaffold through alkaline treatment and type I collagen immobilization10.1016/j.apsusc.2019.01.084 ↗
7. Low-cycle fatigue properties of a titanium alloy exhibiting nonlinear elastic deformation behavior10.1016/j.actamat.2011.04.015 ↗
8. Comparison of the osteoblastic activity of low elastic modulus Ti-24Nb-4Zr-8Sn alloy and pure titanium modified by physical and chemical methods10.1016/j.msec.2020.111018 ↗
9. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty10.1002/jor.23445 ↗
10. Corrosion behaviour of Ti-Nb-Sn shape memory alloys in different simulated body solutions10.1016/j.msea.2006.01.131 ↗
11. Electrochemical and surface analyses of nanostructured Ti-24Nb-4Zr-8Sn alloys in simulated body solution10.1016/j.actbio.2014.02.032 ↗
12. Compressive and fatigue behavior of beta-type titanium porous structures fabricated by electron beam melting10.1016/j.actamat.2016.12.052 ↗
13. Early plastic deformation behaviour and energy absorption in porous β-type biomedical titanium produced by selective laser melting10.1016/j.scriptamat.2018.05.010 ↗
14. Effect of fluoride on the corrosion behavior of nanostructured Ti-24Nb-4Zr-8Sn alloy in acidulated artificial saliva10.1016/j.jmst.2018.01.008 ↗
15. Enhanced corrosion resistance of zinc-containing nanowires-modified titanium surface under exposure to oxidizing microenvironment10.1186/s12951-019-0488-9 ↗
16. Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium10.1002/jbm.a.10116 ↗
17. Warmuth · 2005
18. The effect of simulated inflammatory conditions on the surface properties of titanium and stainless steel and their importance as biomaterials10.1016/j.msec.2016.04.035 ↗
19. The production by leukocytes of superoxide, a potential bactericidal agent10.1172/JCI107236 ↗
20. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
21. The influence of cathodic polarization and simulated inflammation on titanium electrochemistry10.1002/jbm.b.33123 ↗
22. Effects of simulated inflammation on the corrosion of 316L stainless steel10.1016/j.msec.2016.10.012 ↗
23. Albumin coatings by alternating current electrophoretic deposition for improving corrosion resistance and bioactivity of titanium implants10.1016/j.msec.2016.12.129 ↗
24. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
25. The effect of hydrogen peroxide on the electrochemical behavior of ti and some of its alloys for dental applications10.1016/j.matchemphys.2005.10.032 ↗
26. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an in Vitro model of peri-implant inflammation
27. Corrosion behaviour of porous Ti intended for biomedical applications10.1007/s10934-016-0185-0 ↗
28. Electrochemical behavior of open-cellular structured Ti-6Al-4V alloy fabricated by electron beam melting in simulated physiological fluid: the significance of pore characteristics10.1016/j.jmst.2021.05.024 ↗
29. Allergic contact dermatitis caused by titanium screws and dental implants
30. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants-Is one truly better than the other?10.1016/j.msec.2016.01.032 ↗
31. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices-A mini review10.1016/j.toxlet.2021.07.004 ↗
32. Suspected association of an allergic reaction with titanium dental implants: a clinical report10.1016/S0022-3913(08)60233-4 ↗
33. Pain in the well-fixed, aseptic titanium hip replacement - the role of corrosion10.1302/0301-620X.86B1.14326 ↗
34. Do ’passive’ medical titanium surfaces deteriorate in service in the absence of wear?10.1098/rsif.2012.0438 ↗
35. Microstructure, defects and mechanical behavior of beta-type titanium porous structures manufactured by electron beam melting and selective laser melting10.1016/j.actamat.2016.04.029 ↗
36. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
37. A unique hybrid-structured surface produced by rapid electrochemical anodization enhances bio-corrosion resistance and bone cell responses of β-type Ti-24Nb-4Zr-8Sn alloy
38. A synergistic effect of albumin and H2O2 accelerates corrosion of Ti6Al4V10.1016/j.actbio.2015.07.046 ↗
39. Wear-Corrosion synergistic effect on Ti-6Al-4V alloy in H2O2 and albumin environment10.1016/j.jallcom.2020.154539 ↗
40. Time- dependent enhanced corrosion of Ti6Al4V in the presence of H2O2 and albumin
41. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy10.1002/jbm.b.33830 ↗
42. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
43. An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications10.1016/j.msec.2019.110305 ↗
44. Electrochemical characteristics of surface of titanium formed by electrolytic polishing and anodizing10.1007/s10853-005-2802-1 ↗
45. Resemblance in corrosion behavior of selective laser melted and traditional monolithic β Ti-24Nb-4Zr-8Sn alloy10.1021/acsbiomaterials.8b01341 ↗
46. Effect of Nb addition on the stability and biological corrosion resistance of Ti-Zr alloy passivation films10.1016/j.corsci.2020.108696 ↗
47. Atomic emission spectroelectrochemistry: real-time rate measurements of dissolution, corrosion, and passivation10.5006/3336 ↗
48. Corrosion behaviour of biomedical Ti under simulated inflammation: exploring the relevance of grain refinement and crystallographic texture10.1016/j.corsci.2022.110238 ↗