A layer of titanium oxide layer was coated on low temperature isotropic pyrolytic carbon (LTI-carbon), a prevailing material used for artificial heart valves' fabrication, by ion beam enhanced deposition (IBED). Glancing angle x-ray diffraction (GAXRD), X-ray photoelectron spectroscopy (XPS), Rutherford backscattering spectroscopy (RBS), atomic force microscopy (AFM) and transmission electronic microscopy (TEM) were used to characterize the deposited titanium oxide layer. The results show that the layer is polycrystalline with TiO, Ti2O3 and TiO2 coexisting and the root-mean-square (RMS) roughness of the surface is measured to be 8.7 nm. Platelet adhesion experiments show that the adherent platelet on titanium oxide layer is about four times less than that on LTI-carbon. In vivo investigation was performed by implanting LTI-carbon and a titanium oxide layer coated LTI-carbon into the femoral artery of a dog for 4 weeks. By means of scan electron microscopy, coagulation, fibrin, deformed blood red cells and aggregation of adherent platelet were found on the surface of the uncoated LTI-carbon, whereas, nothing but a few normal-shaped blood red cells were found on the titanium oxide coated LTI-carbon. It can be concluded that titanium oxide coated LTI-carbon has a much better blood compatibility than that of the LTI-carbon.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Polymer Nanocomposite Synthesis and Irradiation · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. J. C. Bokros, Carbon 15 (1977) 355.10.1016/0008-6223(77)90324-4 ↗
2. P. Baurschmidt and M. Schaldach, Med. Biol. Eng. Comput. 18 (1980) 496.10.1007/BF02443327 ↗
3. N. Huang, Y. R. Chen, J. M. Luo, J. Yi, R. Lu, J. Xiao, Z. X. Xue and X. H. Liu, J. Biomater. Appl. 8 (1994) 404.10.1177/088532829400800406 ↗
4. Feng Zhang, Zhihong Zheng, Xingzhao Ding, Yingjun Mao, Yu Chen, Zuyao Zhou, Shiqi Yang and Xianghuai Liu, J. Vac. Sci. Technol. A15 (1997) 1824.10.1116/1.580798 ↗
5. Feng Zhang, Zhihong Zheng, Duo Liu, Yinjun Mao, Yu Chen, Zuyao Zhou, Shiqi Yang and Xianghuai Liu, Nuxlear Instruments and Methods in Physics Research B132 (1997) 620.10.1016/S0168-583X(97)00495-3 ↗
6. Feng Zhang, Nan Huang, Ping Yang, Zhihong Zheng, Zuyao, Zhou and Xianghuai Liu, Surface & Coatings Technology 84 (1996) 476.10.1016/S0257-8972(96)02848-4 ↗
7. Xianghuai Liu, Feng Zhang, Zhihong Zheng and Nan Huang, J. Korean Vacuum Society 6(S1) (1997) 1.
8. Zhang Feng, Chen Yu, Zheng Zhihong, Huang Nan, Liu Xianghuai, Chen Anqing and Jiang Zhenbin, Science in China C41(4) (1998) 400.
9. Zengquan Xue, in “Thin Film Physics,” edited by Zengquan Xue (Electron press, 1991) chap II (In Chinese).
10. Lui Xianghuai, Zheng Zhihong and Zhou Zuyao, Journal of Biomaterials Applications 10 (1996) 330.10.1177/088532829601000403 ↗
11. Y. C. Ko, Journal of Colloid and Interface Science 82(1) July 1981.
12. C. P. Sharma, ibid. 97 (1984) 585.10.1016/0021-9797(84)90332-1 ↗
13. D. H. Kaelble and J. Moacanin, Polymer 18 (1977) 475.10.1016/0032-3861(77)90164-1 ↗
14. Fangyan Liu, Meiying Zhou and Feng Zhang, Appl. Radiat. Isot. 49 (1998) 67.10.1016/S0969-8043(97)00262-5 ↗