Electrohydrodynamic Jet-Printed X-ray Sensor Based on Iodide-Exchanged Lead(II) Sulfide Quantum Dots
Source abstract
Abstract
High Resolution Image Download MS PowerPoint Slide The detection of X-rays through innovative solution-processable semiconductors is gaining increasing attention for their widespread applicability in several fields, such as radiology, radiation therapy, and security. Reliable and controllable deposition techniques are pivotal to ensure the repeatability and optimization of devices based on such materials. Here, we used electrohydrodynamic jet (EHD-Jet) printing to fabricate X-ray detectors based on lead sulfide (PbS) quantum dots (QDs) treated with tetrabutylammonium iodide (TBAI). EHD-Jet printing offers significant advantages for scalable device production, allowing precise control over the deposition of the active layer, from nanometer to micrometer thicknesses, which is crucial for tuning device performance. Using a parallel setup with a reference boron-doped diamond dosimeter, we demonstrate a response of the active layer constituted of iodine-exchanged PbS QDs (I-PbS) to hard X-rays (22 keV) with a low-voltage biasing of 1 V. The devices show a linear current–dose rate relation. The best surface-specific sensitivity and limit of detection of S = 431 ± 30 μCGy air –1 cm –2 and LoD = 506.71 nGy air s –1, respectively, are measured, with 10–90% rise/fall times that were found to be <500 ms. This sensitivity is one order of magnitude higher than reported values for commercially available amorphous selenium.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrohydrodynamics and Fluid Dynamics · Diamond and Carbon-based Materials Research · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, via Vito Volterra 62, Rome 00146, Italy
National Institute for Nuclear Physics, INFN Roma Tre Division, via della Vasca Navale 84, Rome 00146, Italy
Department of Sciences, Roma Tre University, via della Vasca Navale 84, Rome 00146, Italy
Funding
Ministero dell?Istruzione, dell?Universit? e della Ricerca · Commissione Scientifica Nazionale 5, Instituto Nazionale di Fisica Nucleare
References (62)
Show source-provided references
1. 10.1002/admt.20200047510.1002/admt.202000475 ↗
2. 10.1007/s40820-024-01393-610.1007/s40820-024-01393-6 ↗
3. 10.1002/aelm.20220029310.1002/aelm.202200293 ↗
4. 10.1038/s41528-022-00229-w10.1038/s41528-022-00229-w ↗
5. 10.1021/acsaelm.3c0098610.1021/acsaelm.3c00986 ↗
6. 10.1021/jacs.9b0127010.1021/jacs.9b01270 ↗
7. PTW microDiamond. https://www.ptwdosimetry.com/en/products/microdiamond (accessed 2025–04–28).
8. 10.1016/j.cap.2005.11.00110.1016/j.cap.2005.11.001 ↗
9. 10.1016/S0022-0248(98)80270-410.1016/S0022-0248(98)80270-4 ↗
10. 10.1007/978-3-031-20955-0_410.1007/978-3-031-20955-0_4 ↗
11. 10.1016/j.jcrysgro.2020.12548210.1016/j.jcrysgro.2020.125482 ↗
12. 10.1134/1.159285110.1134/1.1592851 ↗
13. 10.1002/adom.20200027310.1002/adom.202000273 ↗
14. 10.1088/1361-6528/ab2f4b10.1088/1361-6528/ab2f4b ↗
15. 10.1021/nl503779e10.1021/nl503779e ↗
16. 10.1109/JPROC.2005.85030410.1109/JPROC.2005.850304 ↗
17. 10.1002/ente.20190099110.1002/ente.201900991 ↗
18. 10.1038/srep3791310.1038/srep37913 ↗
19. 10.1039/D0TC04612D10.1039/D0TC04612D ↗
20. 10.1016/j.aca.2020.12.06710.1016/j.aca.2020.12.067 ↗
21. 10.1021/acsaelm.1c0040110.1021/acsaelm.1c00401 ↗
22. 10.1016/j.solener.2011.02.00510.1016/j.solener.2011.02.005 ↗
23. 10.1002/adma.20030539510.1002/adma.200305395 ↗
24. 10.1126/science.aaz854110.1126/science.aaz8541 ↗
25. 10.1126/science.aac552310.1126/science.aac5523 ↗
26. 10.1021/ja510739q10.1021/ja510739q ↗
27. 10.1021/acs.jpclett.9b0086910.1021/acs.jpclett.9b00869 ↗
28. 10.1021/jz200166y10.1021/jz200166y ↗
29. Knoll G. F. · 2010
30. 10.1016/j.orgel.2016.03.02310.1016/j.orgel.2016.03.023 ↗
31. 10.1002/adma.20190164410.1002/adma.201901644 ↗
32. 10.1021/cr900137k10.1021/cr900137k ↗
33. 10.1039/C7TC00038C10.1039/C7TC00038C ↗
34. 10.1007/s00339-022-05796-310.1007/s00339-022-05796-3 ↗
35. 10.1109/JSEN.2014.237520310.1109/JSEN.2014.2375203 ↗
36. Brand O. · 2012
37. 10.1063/5.003166910.1063/5.0031669 ↗
38. 10.1038/nmat197410.1038/nmat1974 ↗
39. 10.1002/smsc.20210007310.1002/smsc.202100073 ↗
40. 10.1002/smll.20150059310.1002/smll.201500593 ↗
41. 10.1021/acs.langmuir.8b0433510.1021/acs.langmuir.8b04335 ↗
42. Ramos A. · 201110.1007/978-3-7091-0900-7 ↗
43. 10.1021/nn500897c10.1021/nn500897c ↗
44. 10.1063/1.496064510.1063/1.4960645 ↗
45. 10.1016/j.jallcom.2023.17065310.1016/j.jallcom.2023.170653 ↗
46. 10.1021/acs.chemmater.2c0278010.1021/acs.chemmater.2c02780 ↗
47. Amptek Mini-X2 X-Ray Tube System for XRF – Amptek – X-Ray Detectors and Electronics. https://www.amptek.com/products/mini-x2-x-ray-tube (accessed 2025–05–08).
48. 10.1016/j.nima.2008.06.02810.1016/j.nima.2008.06.028 ↗
49. 10.1088/1361-6439/ad6e9710.1088/1361-6439/ad6e97 ↗
50. 10.1002/anie.20220016610.1002/anie.202200166 ↗
51. 10.1021/ie301403g10.1021/ie301403g ↗
52. 10.1039/C9NR09651E10.1039/C9NR09651E ↗
53. NIST NIST X-Ray Form Factor, Attenuation and Scattering Tables Form Page. https://physics.nist.gov/PhysRefData/FFast/html/form.html (accessed 2025–03–05).
54. 10.1016/j.apsusc.2018.06.15210.1016/j.apsusc.2018.06.152 ↗
55. 10.1063/1.280080510.1063/1.2800805 ↗
56. 10.1021/nl080373e10.1021/nl080373e ↗
57. 10.1039/C8RA01422A10.1039/C8RA01422A ↗
58. 10.1016/j.tsf.2023.14013810.1016/j.tsf.2023.140138 ↗
59. 10.3390/ma1602082410.3390/ma16020824 ↗
60. 10.1038/s41467-021-25648-710.1038/s41467-021-25648-7 ↗
61. 10.1039/D1EE00832C10.1039/D1EE00832C ↗
62. 10.1002/adma.20200198110.1002/adma.202001981 ↗