Designing Synthetic, Pumping Cilia That Switch the Flow Direction in Microchannels
Source abstract
Abstract
Using computational modeling, we simulate the 3D movement of actuated cilia in a fluid-filled microchannel. The cilia are modeled as deformable, elastic filaments, and the simulations capture the complex fluid-structure interactions among these filaments, the channel walls, and the surrounding solution. The cilia are tilted with respect to the surface and are actuated by a sinusoidal force that is applied at the free ends. We find that these cilia give rise to a unidirectional flow in the system and by simply altering the frequency of the applied force we can controllably switch the direction of the net flow. The findings indicate that beating, synthetic cilia could be harnessed to regulate the fluid streams in microfluidic devices.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Micro and Nano Robotics · Microfluidic and Bio-sensing Technologies · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, The Rudolf Peierls Centre for Theoretical Physics, Oxford University, Oxford, OX1 3NP, U.K., and Chemical Engineering Department, University of Pittsburgh, Pittsburgh, Pennsylvania 15261
References (36)
Show source-provided references
1. Nonaka S. · PLoS Biol. · 2005 · 3 · 146710.1371/journal.pbio.0030268 ↗
2. Cartwright J. H. E. · J. R. Soc. Interface · 2007 · 4 · 4910.1098/rsif.2006.0155 ↗
3. Cartwright J. H. E. · Proc. Natl. Acad. Sci. U.S.A. · 2004 · 101 · 723410.1073/pnas.0402001101 ↗
4. Smith D. J. · J. R. Soc. Interface · 2008 · 5 · 56710.1098/rsif.2007.1306 ↗
5. Smith D. J. · Bull. Math. Biol. · 2007 · 69 · 147710.1007/s11538-006-9172-y ↗
6. Evans B. A. · Nano Lett. · 2007 · 7 · 142810.1021/nl070190c ↗
7. den Toonder J. · Lab Chip · 2008 · 888 · 53310.1039/b717681c ↗
8. Kim Y. W. · Phys. Rev. Lett. · 2006 · 96 · 15810110.1103/PhysRevLett.96.158101 ↗
9. Khatavkar V. V. · Phys. Fluids · 2007 · 19 · 08360510.1063/1.2762206 ↗
10. Mitran S. M. · Comput. Struct. · 2007 · 85 · 76310.1016/j.compstruc.2007.01.015 ↗
11. Gauger E. · Phys. Rev. E · 2006 · 74 · 02190710.1103/PhysRevE.74.021907 ↗
12. Guirao B. · Biophys. J. · 2007 · 92 · 1900−191710.1529/biophysj.106.084897 ↗
13. Gueron S. · Proc. Natl. Acad. Sci. U.S.A. · 1997 · 94 · 600110.1073/pnas.94.12.6001 ↗
14. Gueron S. · Biophys. J. · 1993 · 65 · 499−50710.1016/S0006-3495(93)81062-2 ↗
15. Dillon R. H. · Reprod. Biomech. · 2007 · 1101 · 494
16. Dillon R. H. · Comp. Math. Appl. · 2006 · 52 · 74910.1016/j.camwa.2006.10.012 ↗
17. Gebremichael Y. · Biophys. J. · 2006 · 91 · 3640−365210.1529/biophysj.106.091314 ↗
18. Vilfan A. · Phys. Rev. Lett. · 2006 · 96 · 05810210.1103/PhysRevLett.96.058102 ↗
19. Cosentino Lagomarsino M. · Eur. Phys. J. B · 2002 · 26 · 81−8810.1140/epjb/e20020069 ↗
20. Gauger, E. M., Downton, M. T., and Stark, H.,arXiv:0805.3114v1.
21. Aksak B. · Langmuir · 2007 · 23 · 332210.1021/la062697t ↗
22. Alexeev A. · Macromolecules · 2005 · 38 · 1024410.1021/ma0516135 ↗
23. Alexeev A. · Phys. Rev. Lett. · 2006 · 96 · 14810310.1103/PhysRevLett.96.148103 ↗
24. Alexeev A. · Langmuir · 2007 · 23 · 98310.1021/la062914q ↗
25. Succi S. · 200110.1093/oso/9780198503989.001.0001 ↗
26. Ladd A. J. C. · J. Stat. Phys. · 2001 · 104 · 119110.1023/A:1010414013942 ↗
27. Ladd A. J. C. · Physica A · 1997 · 240 · 34910.1016/S0378-4371(97)00158-1 ↗
28. Ladd A. J. C. · Phys. Rev. E · 1997 · 55 · 327110.1103/PhysRevE.55.3271 ↗
29. Buxton G. A. · Model. Simul. Mater. Sci. · 2001 · 9 · 48510.1088/0965-0393/9/6/302 ↗
30. We assign a value ofk/2 to those springs that are located on the cilia surfaces andk/4 to the springs at the edges. We also set the LSM masses equal tom/2 andm/4 for nodes at the surfaces and edges, respectively.
31. Note that the Poisson’s ratio of polymers can vary from 0.3 to −0.7 and be tailored by blending.(32)Thus, polymers blends with Poisson’s ratios of ∼0.25 can be synthesized.(33)
32. Perez-Rigueiro J. · Polymer · 2000 · 41 · 843310.1016/S0032-3861(00)00179-8 ↗
33. Bureau L. · Mater. Sci. Eng. A · 2001 · 308 · 23310.1016/S0921-5093(00)01980-8 ↗
34. Note that the cilia are constructed from a lattice with only four nodes across. To verify the accuracy of the model, we simulated the bending of a cilium due to a perpendicular force applied to its free end and found that an increase in lattice resolution effectively does not affect the deflection. Note also that for a 50% declination the difference between our LSM model and the linear theory prediction is about 10% and it increases to about 20% for a 100% declination (i.e., when declination is equal to the cilium length).
35. A range of polymeric materials could be used to manufacture artificial cilia with these sperm numbers. As an example, let us consider a cilium that is 10 μm in length and 1 μm in diameter oscillating with a frequency of about 10 Hz in water, whose viscosity is μ ≈ 10−3kg/m·s and density is ρ ≈ 103kg/m3. For such cilia, a sperm number in the range from 1 to 10 can be obtained with polymers having a modulus of approximately 20 Pa−200 kPa, which is in the range of experimentally realistic values. These values yield a bending rigidityEIin the range of 10−24to 10−20N·m2and a driving force amplitude of 0.1 pN <a< 1 nN. Alternatively, the relevant oscillation regimes can be excited by varying the driving frequency in the range of 10 Hz and 100 kHz.
36. Wiggins C. H. · Biophys. J. · 1998 · 74 · 104310.1016/S0006-3495(98)74029-9 ↗