Effect of the Surface Peak–Valley Features on Droplet Impact Dynamics under Leidenfrost Temperature
Source abstract
Abstract
This study explores the kinetic behavior of droplets impacting microtextured surfaces under a Leidenfrost temperature, employing high-speed photography and picosecond laser micromachining techniques. The investigation focuses on two types of microtextured surfaces with totally different surface peak–valley features: a negatively skewed surface with micropit arrays ( Ssk < 0) and a positively skewed surface with micropillar arrays ( Ssk > 0). The results indicate that both microtextured surfaces contribute to a higher Leidenfrost temperature compared with the original smooth surface, which is consistent with previous studies. However, it is worth noting that the Leidenfrost points of the micropit and micropillar surfaces showed opposite trends with the microtexture area occupancy. Specifically, the Leidenfrost temperature on micropit surfaces increases with greater micropit area occupancy, while it decreases on micropillar surfaces under similar conditions, which is mainly attributed to the differential impact of area occupancy on droplet heat transfer efficiency. When the microtexture area occupancy is 50%, it is worth noting that the micropit and micropillar surfaces have nearly same roughness ( Sa ), but the Leidenfrost temperature was notably higher on the micropit surface with negative skewness ( Ssk < 0), which was related to differences in vapor flow dynamics. We further find that the Weber number ( We ) significantly influences the Leidenfrost point, with the droplet impact wall behavior going through the states of film bounce back, ejecting tiny droplets and bounce back, and ultimately droplet breakup as the We increases. The dynamic Leidenfrost point was found to be generally higher than the static point and increases with the We . Finally, we compare the cooling efficiency of these surfaces, and it is found that the micropit surfaces with a negative skewness exhibit superior heat dissipation performance under the same conditions, which proved that the negatively skewed surface may have great potential in high-density heat dissipation technology.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fluid Dynamics and Heat Transfer · Plant Surface Properties and Treatments · Surface Modification and Superhydrophobicity
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Tribology, Hefei University of Technology, Hefei 230009, China
School of Electrical Engineering and Automation, Anhui University, Hefei 230601, China
Funding
National Natural Science Foundation of China · Natural Science Foundation of Anhui Province
References (52)
Show source-provided references
1. 10.1016/0017-9310(66)90111-610.1016/0017-9310(66)90111-6 ↗
2. 10.1063/1.157216110.1063/1.1572161 ↗
3. 10.1021/nn405585m10.1021/nn405585m ↗
4. 10.1021/acs.langmuir.6b0057410.1021/acs.langmuir.6b00574 ↗
5. 10.1146/annurev-fluid-011212-14070910.1146/annurev-fluid-011212-140709 ↗
6. 10.1016/j.ijheatmasstransfer.2023.12463910.1016/j.ijheatmasstransfer.2023.124639 ↗
7. 10.1016/0894-1777(88)90016-710.1016/0894-1777(88)90016-7 ↗
8. 10.1103/PhysRevE.96.04310210.1103/PhysRevE.96.043102 ↗
9. 10.1063/1.480994410.1063/1.4809944 ↗
10. 10.1016/j.ijheatmasstransfer.2018.09.09110.1016/j.ijheatmasstransfer.2018.09.091 ↗
11. 10.1016/j.net.2019.08.02210.1016/j.net.2019.08.022 ↗
12. 10.1016/j.applthermaleng.2020.11568210.1016/j.applthermaleng.2020.115682 ↗
13. 10.1021/acs.langmuir.3c0190510.1021/acs.langmuir.3c01905 ↗
14. 10.1063/5.014472810.1063/5.0144728 ↗
15. 10.1115/1.403612310.1115/1.4036123 ↗
16. 10.1016/j.ijmecsci.2019.05.01510.1016/j.ijmecsci.2019.05.015 ↗
17. 10.1016/j.wear.2019.05.03710.1016/j.wear.2019.05.037 ↗
18. 10.1016/j.ijheatmasstransfer.2023.12463910.1016/j.ijheatmasstransfer.2023.124639 ↗
19. 10.1039/C7NR01845B10.1039/C7NR01845B ↗
20. 10.3901/JME.2018.20.02410.3901/JME.2018.20.024 ↗
21. 10.1016/j.energy.2004.05.00410.1016/j.energy.2004.05.004 ↗
22. 10.1016/j.ijheatmasstransfer.2006.06.03110.1016/j.ijheatmasstransfer.2006.06.031 ↗
23. 10.1016/j.ijheatmasstransfer.2015.01.08410.1016/j.ijheatmasstransfer.2015.01.084 ↗
24. 10.1038/s41586-021-04307-310.1038/s41586-021-04307-3 ↗
25. 10.1007/s11708-018-0541-710.1007/s11708-018-0541-7 ↗
26. 10.1016/j.applthermaleng.2024.12244510.1016/j.applthermaleng.2024.122445 ↗
27. 10.1016/S0017-9310(96)00067-110.1016/S0017-9310(96)00067-1 ↗
28. 10.1115/1.282608010.1115/1.2826080 ↗
29. Baumeister, K. J.; Henry, R.; Simon, F. In Role of the Surface in the Measurement of the Leidenfrost Temperature, Special session on augmentation of convective heat and mass transfer of the AmericanSociety of Mechanical Engineers Winter Annual meeting, 1970.
30. 10.1016/j.ijheatmasstransfer.2018.03.04210.1016/j.ijheatmasstransfer.2018.03.042 ↗
31. 10.1016/0017-9310(87)90126-810.1016/0017-9310(87)90126-8 ↗
32. 10.1039/C3SM27643K10.1039/C3SM27643K ↗
33. 10.1080/01457632.2015.111261010.1080/01457632.2015.1112610 ↗
34. 10.1007/s11434-010-4294-x10.1007/s11434-010-4294-x ↗
35. 10.1021/acs.langmuir.3c0059210.1021/acs.langmuir.3c00592 ↗
36. 10.1021/la302181f10.1021/la302181f ↗
37. 10.1021/acsami.1c0586710.1021/acsami.1c05867 ↗
38. 10.1063/5.016568910.1063/5.0165689 ↗
39. 10.1021/acs.nanolett.3c0504210.1021/acs.nanolett.3c05042 ↗
40. 10.1016/j.carbon.2024.11882410.1016/j.carbon.2024.118824 ↗
41. 10.1063/5.019929110.1063/5.0199291 ↗
42. 10.1063/5.004099010.1063/5.0040990 ↗
43. 10.1002/smll.20230775910.1002/smll.202307759 ↗
44. 10.1021/acs.nanolett.3c0075910.1021/acs.nanolett.3c00759 ↗
45. 10.1063/5.019098610.1063/5.0190986 ↗
46. 10.1021/ja01461a00310.1021/ja01461a003 ↗
47. 10.1063/1.482867310.1063/1.4828673 ↗
48. 10.1016/j.ijheatmasstransfer.2016.03.01110.1016/j.ijheatmasstransfer.2016.03.011 ↗
49. Park I. W. · 2016 · V001T009A001
50. 10.1021/acs.langmuir.0c0115110.1021/acs.langmuir.0c01151 ↗
51. 10.1115/1.165204510.1115/1.1652045 ↗
52. 10.1115/1.147048710.1115/1.1470487 ↗