journal article·2002-12-01

Polyethylene-co-acrylic Acid as Coating for Biosensor Application: A Quartz Crystal Microbalance Study

Kok Ting Chong, Xiaodi Su, Edmund J. D. Lee, S. J. O'Shea

Langmuir· Volume 18· Issue 25
Publisher page

Abstract

This study describes the use of an acrylic acid containing random copolymer (polyethylene- co -acrylic acid, PEAA) as quartz crystal microbalance (QCM) coatings for electrode shielding and covalent tethering of DNA oligonucleotides. Commercially available silver-coated QCM was used as reaction carriers, onto which PEAA was coated to protect the electrode from undesirable effects of oxidation. AFM and SEM/EDX were used to analyze the topology and coverage of the polymer coatings. Carbodiimide chemistry was applied to attach a 17- mer single-stranded DNA probe with a C 12 -alkylamino tail on the 5‘-end. Seventy -mer single-stranded DNA (ss-DNA) fragments containing complementary or noncomplementary sequences were hybridized to the end-attached probes. With the use of a high stringency hybridization buffer (2 × SSC with 2% SDS), the QCM-based DNA sensor was able to detect and differentiate single-base mismatches in the 70 -mer DNA target sequence . The response to the single-base mismatches near the 5‘ end or at the center of the immobilized probe was only ∼60% and ∼50% of that to the fully complementary sequence, respectively. The carbodiimide chemistry responsible for DNA immobilization creates a strong covalent bond that allows the probe modified surface to be reused upon denaturing the hybrids.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Acoustic Wave Resonator Technologies · Advanced biosensing and bioanalysis techniques · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Pharmacogenetics Laboratory, Department of Pharmacology, National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260, and Institute of Materials Research and Engineering, 3 Research Link, Singapore 117602

References (19)

Show source-provided references
1. Sakti S. P. · Sens. Actuators, A · 1999 · 76 · 9810.1016/S0924-4247(98)00358-6 ↗
2. Su X. D. · Analyst · 2000 · 125 · 226810.1039/b006895k ↗
3. Su X. D. · Biochem. Biophys. Res. Commun. · 2002 · 290 · 96210.1006/bbrc.2001.6297 ↗
4. Wessa T. · J. Biosens. Bioelectron. · 1999 · 14 · 9310.1016/S0956-5663(98)00087-6 ↗
5. Wessa T. · Colloids Surf. B · 1999 · 15 · 13910.1016/S0927-7765(99)00047-8 ↗
6. Barie N. · J. Biosens. Bioelectrons. · 1998 · 13 · 85510.1016/S0956-5663(98)00052-9 ↗
7. Jones R. A. L. · 199910.1017/CBO9780511623196 ↗
8. Nasreddine V. · Macromolecules · 2001 · 34 · 740310.1021/ma010833p ↗
9. Zhang P. · Anal. Biochem. · 2000 · 282 · 21810.1006/abio.2000.4610 ↗
10. Zhang P. · Macromolecules · 1999 · 32 · 214910.1021/ma9814088 ↗
11. Sano S. · Biomaterials · 1993 · 14 · 81710.1016/0142-9612(93)90003-K ↗
12. Schultz, J. S.Handbook of Chemical and Biological Sensor; Institute of Physics Publishing: Philadelphia, 1996; p 155.
13. Xia S. J. · Langmuir · 2000 · 16 · 137910.1021/la9907735 ↗
14. Daikhin L. · Langmuir · 1996 · 12 · 635410.1021/la950763d ↗
15. Daikhin L. · Faraday Discuss. · 1997 · 107 · 2710.1039/a703124f ↗
16. Cavic B. A. · Analyst · 1999 · 124 · 140510.1039/a903236c ↗
17. Su X. D. · Anal. Biochem. · 1999 · 273 · 6610.1006/abio.1999.4186 ↗
18. Huang E. · Langmuir · 2000 · 16 · 327210.1021/la9910834 ↗
19. Okahata Y. · J. Am. Chem. Soc. · 1992 · 114 · 829910.1021/ja00047a056 ↗