journal article·2025-01-13

Practical and Thermodynamic Limits of Dual-Use, Potentiometric Energy Harvesters for Self-Powered Sensors

Ajanta Saha, Muhammad Ashraful Alam

ACS Applied Energy Materials· Volume 8· Issue 1
Publisher page

Abstract

Energy-autonomous ion-selective electrode (ISE) sensors (that would not require any battery or secondary energy harvester for signal acquisition and transmission) will find broad application in wearable and implantable devices for continuous health monitoring, smart agriculture, and environmental sensing. Although ISEs have been used as sensors for more than 50 years, their practical and thermodynamic potential as an energy harvester has not been explored. An ISE measures target ion concentration by the selective uptake of ions in the membrane. The concentration gradient across the membrane–solution boundary produces harvestable Gibbs free energy of mixing. The power harvested so far has been in the nW/cm 2 range, raising questions about the viability of the approach. Here, we present a model to calculate the theoretical and practical power harvest limit of an ISE. We show that the thermodynamic performance limit should approach mW/cm 2 in the limit of zero sensor and solution resistance. Indeed, we demonstrate experimentally that simple improvements in sensor electrodes can improve power harvest by 3 orders of magnitude, i.e., 100 s of nW/cm 2 . This power is sufficient to support a low-powered wearable, implantable device.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Advanced Sensor and Energy Harvesting Materials · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States

Funding

Wabash Heartland Innovation Network · Purdue University

References (33)

Show source-provided references
1. 10.1021/acs.est.2c0356210.1021/acs.est.2c03562 ↗
2. 10.1063/5.018753910.1063/5.0187539 ↗
3. 10.1038/nbt.239410.1038/nbt.2394 ↗
4. 10.1109/LMWC.2022.316731110.1109/LMWC.2022.3167311 ↗
5. 10.1038/s41587-023-01827-310.1038/s41587-023-01827-3 ↗
6. 10.1007/s12274-021-3330-810.1007/s12274-021-3330-8 ↗
7. 10.1007/s12274-023-5879-410.1007/s12274-023-5879-4 ↗
8. 10.1021/acs.chemrev.3c0030510.1021/acs.chemrev.3c00305 ↗
9. 10.1002/adfm.20190624310.1002/adfm.201906243 ↗
10. 10.1063/5.004934710.1063/5.0049347 ↗
11. 10.1021/es300060m10.1021/es300060m ↗
12. 10.1016/j.desal.2020.11484110.1016/j.desal.2020.114841 ↗
13. 10.1126/science.191.4227.55710.1126/science.191.4227.557 ↗
14. 10.1002/anie.20231594710.1002/anie.202315947 ↗
15. 10.1103/PhysRevLett.103.05850110.1103/PhysRevLett.103.058501 ↗
16. 10.1039/D1SE00562F10.1039/D1SE00562F ↗
17. 10.1142/s273759942240003510.1142/s2737599422400035 ↗
18. Makarychev-Mikhailov S. · 2008 · 7110.1016/B978-012373738-0.50006-4 ↗
19. 10.1021/acsaelm.4c0006410.1021/acsaelm.4c00064 ↗
20. 10.1021/es401391710.1021/es4013917 ↗
21. 10.1021/es201275810.1021/es2012758 ↗
22. 10.1109/TBME.2021.308744410.1109/TBME.2021.3087444 ↗
23. 10.1109/JSEN.2022.317829710.1109/JSEN.2022.3178297 ↗
24. 10.1021/acs.analchem.2c0155710.1021/acs.analchem.2c01557 ↗
25. 10.1126/science.191.4227.55710.1126/science.191.4227.557 ↗
26. 10.1021/acssensors.2c0116310.1021/acssensors.2c01163 ↗
27. 10.1021/je101012n10.1021/je101012n ↗
28. 10.1088/0143-0815/8/4a/00210.1088/0143-0815/8/4a/002 ↗
29. 10.1021/acssensors.0c0128410.1021/acssensors.0c01284 ↗
30. 10.1021/acs.analchem.0c0511710.1021/acs.analchem.0c05117 ↗
31. 10.1021/acssensors.2c0153310.1021/acssensors.2c01533 ↗
32. Datta, A.; Sen, S. Invited: Can Wi-R Enable Perpetual IoB Nodes? 2023, arXiv preprint arXiv:2307.11213.10.1109/BioCAS58349.2023.10388539 ↗
33. 10.1109/JSSC.2014.231623710.1109/JSSC.2014.2316237 ↗