Spontaneous Draining of Liquids from Vertically Oriented Tubes
Source abstract
Abstract
This paper describes experiments where liquid-filled tubes, with the bottom ends open, were pulled vertically from a reservoir. If the open diameter on the bottom of the tubes was sufficiently small, liquid was retained. Otherwise, if sufficiently large, the tubes drained from the bottom up. The critical diameter of the opening at the bottom of the tubes ranged from 10-15 mm for water to >5 mm for a dense, low surface tension, perfluoroether oil. The ability of relatively large diameter tubes to retain liquid is attributed to a combination of materials properties and atmospheric pressure. If surface tension were acting alone, the tubes would have had to be much smaller to prevent drainage or spillage.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fluid Dynamics and Heat Transfer · Enhanced Oil Recovery Techniques · Fluid Dynamics and Mixing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
CPC, Inc., 1001 Westgate Drive, St. Paul, Minnesota 55114, United States
References (12)
Show source-provided references
1. Wu S. · 1982
2. Adamson A. W. · 1990
3. Weast R. C. · 1992
4. DuPont Krytox VPF Vacuum Pump Fluids, Product Information; H-58530; E. I. du Pont de Nemours and Company, December, 2012.
5. Laplace P. S. · 1805 · 4
6. 10.1098/rsta.1973.011310.1098/rsta.1973.0113 ↗
7. 10.1063/1.219531410.1063/1.2195314 ↗
8. 10.1146/annurev.fluid.30.1.8510.1146/annurev.fluid.30.1.85 ↗
9. Savart F. · Ann. Chim. (Paris) · 1833 · 53 · 337
10. Plateau J. · 1873 · 1
11. 10.1112/plms/s1-10.1.410.1112/plms/s1-10.1.4 ↗
12. 10.1098/rspl.1879.001510.1098/rspl.1879.0015 ↗