Understanding the Adsorption and Desorption of Sitagliptin Phosphate Monohydrate on SS2343, Glass, and PTFE Using QCM-D and Raman Spectroscopy
Source abstract
Abstract
Cross-contamination during pharmaceutical drug manufacturing can result in expensive recalls. To counter that, companies spend significant time and resources to ensure equipment cleanliness, often relying on the compound solubility data in various solvents as the main indicator of cleaning success. The aim of this work is to provide an alternative way to analyze the fouling and cleaning of surfaces in pharmaceutical manufacturing processes by using the quartz crystal microbalance with dissipation (QCM-D) and Raman spectroscopy. In this study, we chose an active pharmaceutical ingredient (API), sitagliptin phosphate monohydrate (SIT), as the model drug compound and observed its adsorption and desorption on stainless steel (SS2343), borosilicate glass (glass), and polytetrafluoroethylene (PTFE) surfaces. SIT was selected as the model API since it is a product manufactured on a large scale and is part of the widely used dipeptidyl peptidase-IV inhibitor class of oral hypoglycemics used to treat type 2 diabetes mellitus, while the chosen surfaces mimic the wall materials of manufacturing equipment and components such as reactors, transfer lines, and valves. Both the QCM-D and Raman spectroscopy results show the highest physisorption on PTFE, followed by SS2343 and glass. Additionally, QCM-D revealed a harder removal of SIT from SS2343 compared to glass and PTFE. Raman analysis of the chemical interactions disclosed C-F and C═O bond interactions between SIT and the surfaces, and the lack of a peak shift suggested dipole-dipole interactions. Furthermore, contact angle measurements indicate that hydrophobic attraction contributed to SIT adhesion to the PTFE surface. Subsequently, SIT coverage upon deposition on a PTFE surface has a significantly smaller surface area than on SS2343 and glass due to surface hydrophobicity, hence resulting in a longer removal time. These results provide a practical use of QCM-D and Raman spectroscopy to enhance the understanding of fouling and improve the cleaning of complex small molecules on relevant surfaces during the pharmaceutical manufacturing process.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Acoustic Wave Resonator Technologies · Protein purification and stability · Crystallization and Solubility Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Food, Chemical and Biotechnology Cluster, Singapore Institute of Technology, 10 Dover Drive, Singapore 138683
Institute of Sustainability for Chemicals, Energy and Environment, Agency for Science, Technology and Research (A*STAR), 1 Pesek Road, Jurong Island, Singapore 627833
Funding
Singapore Institute of Manufacturing Technology
References (39)
Show source-provided references
1. 10.4103/2230-973X.14722210.4103/2230-973X.147222 ↗
2. 10.1016/j.apsb.2015.09.00910.1016/j.apsb.2015.09.009 ↗
3. Shanley, A. Pharma Manufacturing. cGMP Judgment Day. https://www.pharmamanufacturing.com/articles/2012/159/ (accessed Dec 16, 2021).
4. Chapman, J. Redica Systems. Cleaning and Cross-contamination Issues with an Encapsulator: CGMP Inspection Case Study by FDA National Drug Expert Ileana Barreto-Pettit. https://redica.com/pharma-cleaning-and-cross-contamination-issues-with-an-encapsulator-cgmp-inspection-case-study-by-fda-national-drug-expert-ileana-barreto-pettit/ (accessed Dec 16, 2021).
5. 10.1016/j.yrtph.2016.05.02910.1016/j.yrtph.2016.05.029 ↗
6. ECA Academy. Cross Contamination: One of FDA’s Current Issues. https://www.gmp-compliance.org/gmp-news/cross-contamination-one-of-fdas-current-issues (accessed Dec 16, 2021).
7. Rivera, E. PharmTech. Basic Equipment-Design Concepts to Enable Cleaning in Place: Part I. https://www.pharmtech.com/view/basic-equipment-design-concepts-enable-cleaning-place-part-i (accessed Dec 16, 2021).
8. 10.1021/acs.analchem.9b0465810.1021/acs.analchem.9b04658 ↗
9. 10.1039/D0AN01219J10.1039/D0AN01219J ↗
10. Walsh A. · Pharm. Eng. · 2011 · 31 · 74
11. FDA. Questions and Answers on Current Good Manufacturing Practices─Equipment. https://www.fda.gov/drugs/guidances-drugs/questions-and-answers-current-good-manufacturing-practices-equipment (accessed Dec 16, 2021).
12. Bader, K.; Jordan, K.; Forsyth, R. J. PharmTech. Ruggedness of Visible Residue Limits for Cleaning-Part III: Visible Residue Limits for Different Materials of Construction. https://www.pharmtech.com/view/ruggedness-visible-residue-limits-cleaning-part-iii-visible-residue-limits-different-materials-const (accessed Dec 16, 2021).
13. Forsyth R. J. · J. Valid. Technol. · 2009 · 15 · 91
14. National Library of Medicine. Sitagliptin phosphate monohydrate. https://pubchem.ncbi.nlm.nih.gov/compound/Sitagliptin-phosphate-monohydrate (accessed Dec 16, 2021).
15. 10.1021/acs.langmuir.9b0231810.1021/acs.langmuir.9b02318 ↗
16. 10.1021/acs.langmuir.9b0304210.1021/acs.langmuir.9b03042 ↗
17. 10.1021/acs.langmuir.7b0096810.1021/acs.langmuir.7b00968 ↗
18. 10.1021/acs.energyfuels.1c0279910.1021/acs.energyfuels.1c02799 ↗
19. Edvardsson, M. Biolin Scientific. How does QCM-technology work? https://www.biolinscientific.com/blog/how-does-qcm-technology-work (accessed Dec 16, 2021).
20. Biolin Scientific. QCM-D Measurement. https://www.biolinscientific.com/measurements/qcm-d (accessed Dec 16, 2021).
21. 10.1021/acs.langmuir.0c0010410.1021/acs.langmuir.0c00104 ↗
22. 10.1021/acsami.7b0277410.1021/acsami.7b02774 ↗
23. 10.1007/BF0133793710.1007/BF01337937 ↗
24. 10.1021/ac060302510.1021/ac0603025 ↗
25. Omnexus. Polytetrafluoroethylene (PTFE): Everything You Need to Know. https://omnexus.specialchem.com/selection-guide/polytetrafluoroethylene-ptfe-fluoropolymer (accessed Dec 16, 2021).
26. Fuller D. D. · 1972
27. FDA. Guidance for Industry, Q7A Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/guidance-industry-q7a-good-manufacturing-practice-guidance-active-pharmaceutical-ingredients#P1079_80165 (accessed Jul 24, 2022).
28. 10.3390/app1006211310.3390/app10062113 ↗
29. 10.1016/j.saa.2020.11890010.1016/j.saa.2020.118900 ↗
30. 10.1039/C5TC02174J10.1039/C5TC02174J ↗
31. 10.1016/B978-0-444-63359-0.00006-910.1016/B978-0-444-63359-0.00006-9 ↗
32. 10.1021/jp504568c10.1021/jp504568c ↗
33. 10.1039/D0CP05280A10.1039/D0CP05280A ↗
34. 10.1080/15583058.2017.129085010.1080/15583058.2017.1290850 ↗
35. 10.1016/j.foodhyd.2019.10519510.1016/j.foodhyd.2019.105195 ↗
36. 10.1016/j.apsusc.2018.04.18010.1016/j.apsusc.2018.04.180 ↗
37. 10.1016/j.memsci.2009.06.00110.1016/j.memsci.2009.06.001 ↗
38. Forsyth, R. J. Equipment Hold-Time for Cleaning Validation https://www.pharmtech.com/view/equipment-hold-time-cleaning-validation (accessed Apr 18, 2022).