Connected Droplet Shape Analysis for Nanoflow Quantification in Thin Electroosmotic Micropumps and a Tunable Convex Lens Application

Sai Siva Kare, Pradeep Kumar Ramkumar, Yuan Gao, Jie Xu, John Desmond Finan

Langmuir· Volume 39· Issue 7

Abstract

Thin electroosmotic flow (EOF) micropumps can generate flow in confined spaces such as lab-on-a-chip microsystems and implantable drug delivery devices. However, status quo methods for quantifying flow and other important parameters in EOF micropumps depend on microfluidic interconnects or fluorescent particle tracking: methods that can be complex and error-prone. Here, we present a novel connected droplet shape analysis (CDSA) technique that simplifies flow rate and zeta potential quantification in thin EOF micropumps. We also show that a pair of droplets connected by an EOF pump can function as a tunable convex lens system (TCLS). We developed a biocompatible and all polymer EOF micropump with an SU-8 substrate and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) electrodes. We microdrilled a channel through the electrode/SU-8/electrode layers to realize a monolithic EOF micropump. Then, we deposited a pinned droplet on each end of the microchannel so that it connected them. By controlling the EOF between the droplets and measuring the corresponding change in their shape, we quantified the nanoliter EOF rate and zeta potential at the interface of SU-8 with two liquids (deionized water and a l-glutamate neurotransmitter solution). When the droplet pair and pump were used as a TCLS, CDSA successfully predicted how the focal length would change when the pump drove fluid from one droplet to another. In summary, CDSA is a simple low-cost technique for EOF rate and zeta potential measurement, and a pair of droplets connected by an EOF micropump can function as a TCLS without any moving parts.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Electrowetting and Microfluidic Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States

Funding

National Institute of Biomedical Imaging and Bioengineering · University of Illinois at Chicago

References (38)

Show source-provided references
1. 10.1007/s10404-008-0399-910.1007/s10404-008-0399-9 ↗
2. 10.1016/j.aca.2019.02.00410.1016/j.aca.2019.02.004 ↗
3. 10.1002/elps.20200031310.1002/elps.202000313 ↗
4. 10.1007/s10544-007-9130-y10.1007/s10544-007-9130-y ↗
5. 10.1039/C6NR02937J10.1039/C6NR02937J ↗
6. 10.1088/1741-2552/ac00d310.1088/1741-2552/ac00d3 ↗
7. 10.1007/s10404-018-2046-410.1007/s10404-018-2046-4 ↗
8. 10.1073/pnas.130810911010.1073/pnas.1308109110 ↗
9. 10.1039/C2LC40059F10.1039/C2LC40059F ↗
10. 10.1016/j.sna.2011.12.05010.1016/j.sna.2011.12.050 ↗
11. 10.1021/ja301715810.1021/ja3017158 ↗
12. 10.1007/s10404-017-2017-110.1007/s10404-017-2017-1 ↗
13. 10.1002/adma.20100169410.1002/adma.201001694 ↗
14. 10.1063/1.216253310.1063/1.2162533 ↗
15. 10.1007/s00348-007-0366-310.1007/s00348-007-0366-3 ↗
16. 10.1073/pnas.050532410210.1073/pnas.0505324102 ↗
17. 10.1016/j.orgel.2016.04.00410.1016/j.orgel.2016.04.004 ↗
18. 10.1039/D0QM00529K10.1039/D0QM00529K ↗
19. 10.1021/ac502596m10.1021/ac502596m ↗
20. 10.1039/B503016A10.1039/B503016A ↗
21. 10.1006/jcis.2000.678310.1006/jcis.2000.6783 ↗
22. 10.1016/S0021-9797(03)00142-510.1016/S0021-9797(03)00142-5 ↗
23. 10.1038/srep0141210.1038/srep01412 ↗
24. 10.1016/S0021-9797(02)00198-410.1016/S0021-9797(02)00198-4 ↗
25. 10.1088/0960-1317/18/8/08700210.1088/0960-1317/18/8/087002 ↗
26. 10.1039/B707637A10.1039/B707637A ↗
27. 10.1016/j.colsurfa.2016.12.03010.1016/j.colsurfa.2016.12.030 ↗
28. 10.1016/j.snb.2012.05.05810.1016/j.snb.2012.05.058 ↗
29. Hunter R. J. · 1981
30. Tokaty G. A. · 1994
31. 10.1021/la802949z10.1021/la802949z ↗
32. 10.1002/anie.20151202510.1002/anie.201512025 ↗
33. 10.1039/D1SM01725J10.1039/D1SM01725J ↗
34. 10.1038/s41467-020-19054-810.1038/s41467-020-19054-8 ↗
35. 10.3389/frobt.2021.67804610.3389/frobt.2021.678046 ↗
36. 10.1364/OE.20.01818010.1364/OE.20.018180 ↗
37. 10.1364/AO.54.00622410.1364/AO.54.006224 ↗
38. 10.1039/D0LC00144A10.1039/D0LC00144A ↗