journal article·2025-03-04

Enhanced Bioactive Compound Absorption on PMMA Microwell Plates via Fine Controlling Air Plasma Treatment Time for Disease Diagnosis Applications

Hailong Wang, Mengyao Wang, Jibo Tang, Yiman Zhang, Qingqian Wang, Yangming Hu, Wenjun Zhang, Xiaobo He, Hongxing Xu

Langmuir· Volume 41· Issue 8
Publisher page

Abstract

Microwell plates absorb bioactive compounds and are commonly used for disease prediction, diagnosis, and monitoring. Chemical absorption is more effective than physical absorption for stabilizing these compounds. This study systematically investigates the fundamental mechanisms of air plasma-induced surface modifications in poly(methyl methacrylate) (PMMA), focusing on carboxyl group formation kinetics, morphological evolution, and optical property changes. Air plasma treatment enhances the hydrophilicity and surface roughness of the PMMA plates. Light transmission remains comparable to untreated plates for 10 min treatment durations. Treatment for 3 min significantly increases the large-molecular-weight carboxyl compounds, with minimal loss after wash buffer rinsing. Thus, a 3 min air plasma treatment optimally enhances PMMA microwell plates for effective bioactive compound absorption.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · 3D Printing in Biomedical Research · Nanofabrication and Lithography Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Physics, Henan Academy of Sciences

School of Physics

Henan Normal University

Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology

Wuhan University

Funding

National Natural Science Foundation of China · Henan Academy of Sciences

References (31)

Show source-provided references
1. 10.1373/clinchem.2005.05153210.1373/clinchem.2005.051532 ↗
2. 10.1038/nbt.249210.1038/nbt.2492 ↗
3. 10.1038/nrd198510.1038/nrd1985 ↗
4. 10.1038/nprot.2011.30410.1038/nprot.2011.304 ↗
5. 10.1116/1.497843510.1116/1.4978435 ↗
6. 10.1016/S0022-1759(99)00051-410.1016/S0022-1759(99)00051-4 ↗
7. 10.1006/meth.2000.103110.1006/meth.2000.1031 ↗
8. 10.1021/am100566e10.1021/am100566e ↗
9. 10.1021/acs.analchem.1c0365410.1021/acs.analchem.1c03654 ↗
10. 10.1016/j.apsusc.2022.15560310.1016/j.apsusc.2022.155603 ↗
11. 10.1016/j.colsurfb.2022.11300310.1016/j.colsurfb.2022.113003 ↗
12. 10.1021/la304287v10.1021/la304287v ↗
13. 10.1007/s13204-013-0290-110.1007/s13204-013-0290-1 ↗
14. 10.1007/s00216-018-1019-510.1007/s00216-018-1019-5 ↗
15. 10.1016/j.surfcoat.2010.07.01610.1016/j.surfcoat.2010.07.016 ↗
16. 10.1007/s10047-020-01173-010.1007/s10047-020-01173-0 ↗
17. 10.1016/j.aca.2009.06.04810.1016/j.aca.2009.06.048 ↗
18. 10.1007/s10047-022-01323-610.1007/s10047-022-01323-6 ↗
19. 10.1016/j.apsusc.2014.08.16710.1016/j.apsusc.2014.08.167 ↗
20. Farahmand, E.; Ibrahim, F.; Hosseini, S.; Rothan, H. A.; Mokhtar, M. S.; Djordjevic, I. In Optimization of ELISA Buffers Vol. for CD-based Microfluidic Biosensors. In 2014 IEEE Conference on Biomedical Engineering and Sciences (IECBES), 8–10 Dec. 2014; IEEE, 2014; pp 575–577.10.1109/IECBES.2014.7047568 ↗
21. 10.1021/acsami.9b1463110.1021/acsami.9b14631 ↗
22. 10.1016/j.vacuum.2011.07.00510.1016/j.vacuum.2011.07.005 ↗
23. 10.1038/s41598-021-88553-510.1038/s41598-021-88553-5 ↗
24. 10.1002/ppap.20090011310.1002/ppap.200900113 ↗
25. 10.3390/coatings904022810.3390/coatings9040228 ↗
26. 10.1016/j.apsusc.2016.01.19910.1016/j.apsusc.2016.01.199 ↗
27. 10.1016/j.polymdegradstab.2012.03.02910.1016/j.polymdegradstab.2012.03.029 ↗
28. 10.1007/BF0090915910.1007/BF00909159 ↗
29. 10.1016/j.cplett.2005.02.12410.1016/j.cplett.2005.02.124 ↗
30. 10.1021/jp022602610.1021/jp0226026 ↗
31. 10.1063/1.168831210.1063/1.1688312 ↗