journal article·2009-01-28

Multiplex Lateral-Flow Test Strips Fabricated by Two-Dimensional Shaping

Erin M. Fenton, Monica R. Mascarenas, Gabriel P. López, Scott S. Sibbett

Publisher page

Abstract

We have fabricated paper- and nitrocellulose-based lateral-flow devices that are shaped in two dimensions by a computer-controlled knife. The resulting star, candelabra, and other structures are spotted with multiple bioassay reagents to produce multiplex lateral-flow assays. We have also fabricated laminar composites in which porous nitrocellulose media are sandwiched between vinyl and polyester plastic films. This minimizes evaporation, protects assay surfaces from contamination and dehydration, and eliminates the need for the conventional hard plastic cassette holders that are typically used to package commercial lateral-flow diagnostic strips. The reported fabrication method is novel, low-cost, and well-suited to (i) fabrication and adoption in resource-poor areas, (ii) prototype development, (iii) high-volume manufacturing, and (iii) improving rates of operator error.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Biosensors and Analytical Detection · Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Center for Biomedical Engineering and Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, New Mexico 87131

References (28)

Show source-provided references
1. Free A. H. · Clin. Chem. · 1957 · 3 · 16310.1093/clinchem/3.3.163 ↗
2. Free H. M. · Clin. Chem. · 1960 · 6 · 35210.1093/clinchem/6.4.352 ↗
3. Brunzel, N. A.Fundamentals of Urine and Body Fluid Analysis,2nded.Saunders:New York, 2004; pp123−163.
4. Strasinger, S. K. and DiLorenzo, M. S.Urinalysis and Body Fluids,4thed.F. A. Davis Company:Philadelphia, 2001; pp44−64.
5. Hawkes R. · Anal. Biochem. · 1982 · 119 · 14210.1016/0003-2697(82)90677-7 ↗
6. Binder S. R. · Lupus · 2006 · 15 · 41210.1191/0961203306lu2326oa ↗
7. Rosenstein, R. W. and Bloomster, T. G.U.S. Patent 4,855,240, 1989.
8. Gordon, J., McMahon, M. E., and Ching, S.U.S. Patent 4,960,691, 1990.
9. Dullen F. A. L. · 1979
10. Haeberle S. · Lab Chip · 2007 · 7 · 109410.1039/b706364b ↗
11. 2006
12. Pawlak, C., Provonost, A. D., and Goins, K.U.S. Patent 5,766,961, 1998.
13. Eisinger, R. W., Khalil, M. H., Katz, D. H., and Sargeant, R. B.U.S. Patent 4,943,522, 1990.
14. Quidel QuickVue;Quidel Corp.:San Diego, CA,www.quidel.com.
15. Dineva M. A. · J. Clin. Microbiol. · 2005 · 43 · 401510.1128/JCM.43.8.4015-4021.2005 ↗
16. Martinez A. W. · Angew. Chem., Int. Ed. · 2007 · 46 · 131810.1002/anie.200603817 ↗
17. Bartholomeusz D. A. · J. Microelectromech. Syst. · 2005 · 14 · 136410.1109/JMEMS.2005.859087 ↗
18. Brooks T. · Lett. Appl. Microbiol. · 1997 · 24 · 20310.1046/j.1472-765X.1997.00378.x ↗
19. We have also cutunbackedsheets of both nitrocellulose and chromatography paper by first mating each with a more rigid substrate, viz., adhesive-coated overhead projector transparencies. However, once cut, we find that the task of delaminating the original unbacked sheet from the transparency, if possible, requires 10−60 min because of the low structural strength of nitrocellulose or chromatography paper.
20. Additional tests of uniform flow were performed with eight-arm type 3 stars, which had been prespotted with granular solid inorganic dyes, a different dye for each of the eight arms. Upon application of water to the center hole of these devices, the ensuing lateral flow migrates across the lines of dye, solubilizing the dye, and generating a distinct color on each arm. In this case, the rate of advancement of the visible dye front was observed to vary from arm to arm and, in some cases, laterally across an arm (photograph in theSupporting Information). We interpret this to indicate that granules of dye deposited atop nitrocellulose are not uniformly wetted and solubilized, as might be expected for different dyes, and/or when flow occurs primarily within, not atop, the nitrocellulose.
21. Supporting information of ref16.
22. Rao R. S. · Proc. SPIE · 2005 · 6007 · 600711-1
23. The U.S. Clinical Laboratory Improvement Act of 1988, (CLIA 88) requires FDA clearance of new test technologies. Tests deemed to be of “moderate or high complexity” (i.e., those requiring special knowledge and training, complex equipment, or both) require vigorous quality control, including proficiency and com-petency training for end users. In the U.S., most tests of moderate or high complexity are performed in clinical reference labs. Point-of-care and/or home-use marketers tend to focus on known testing techniques, such as immunorecognition, which are waived under CLIA 88.
24. Kost G. J. · Arch. Pathol. Lab. Med. · 2001 · 125 · 130710.5858/2001-125-1307-PMEIPO ↗
25. Nichols J. H. · Accred. Qual. Assur. · 2006 · 11 · 27310.1007/s00769-006-0130-z ↗
26. The manufacturer’s suggested retail price of a 3.77 × 9064 cm roll of Whatman Chr 1 is about U.S. $40 (∼$12/m2); for Millipore HF135, 30 × 10 000 cm, it is U.S. $5000 (∼$166/m2). These prices do not reflect volume discounts; hence, the costs per device given in the text are approximate upper limits.
27. Nat. Methods · 2007 · 4 · 87710.1038/nmeth1120 ↗
28. Grant R. M. · Nat. Methods · 2007 · 4 · 88710.1038/nmeth1119 ↗