Interface-Limited Amperometric Cholesterol Biosensing in Ultrathin Pd-NPs-Based-Enzyme Films
Source abstract
Abstract
Abstract This manuscript investigates the limitations of enzyme–electrocatalyst coupling in one-step designed amperometric cholesterol biosensors. One-step electrodeposition from Pd-ChOx-Nafion electrolyte produces a bioinorganic hybrid sensing layer, while preserving the enzyme’s native conformation and biocatalytic activity. Despite structural coupling between Pd and ChOx, the amperometric response remains dominated by enzymatic H2O2 production, indicating that direct electronic communication between ChOx and the electrode is not established. More specifically, we show that direct electron transfer (DET) cannot occur even in ultrathin electrodeposited nanostructured films, likely due to oxygen-dominated electrochemistry. Furthermore, the sensitivity of cholesterol determination using Pd-NPs/ChOx/Nafion-modified electrodes was independent of layer thickness and architecture, highlighting the limitations of the Pd-NPs–enzyme interface. These findings provide mechanistic insight into ultrathin enzyme–electrocatalyst interfaces and are expected to impact the development of next-generation cholesterol biosensors.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques · Lipid Membrane Structure and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Saarland University , , Campus B2.2 , , ,
HTW saar − University of Applied Sciences , , ,
Korea Institute of Science and Technology , , , ,
Funding
Deutsche Forschungsgemeinschaft
References (38)
Show source-provided references
1. Amperometric Cholesterol Biosensor Based on Cholesterol Oxidase and Pt-Au/MWNTs Modified Glassy Carbon Electrode10.1016/j.matpr.2021.03.128 ↗
2. Construction of an Amperometric Cholesterol Biosensor Based on DTP(Aryl)Aniline Conducting Polymer Bound Cholesterol Oxidase10.1002/elan.201800248 ↗
3. Immobilization of Cholesterol Oxidase: An Overview10.2174/1874070701812010176 ↗
4. Amperometric Cholesterol Biosensors Based on the Electropolymerization of Pyrrole and the Electrocatalytic Effect of Prussian-Blue Layers Helped with Self-Assembled Monolayers10.1016/j.talanta.2004.03.038 ↗
5. Covalent Immobilization of Cholesterol Oxidase on Self-Assembled Gold Nanoparticles for Highly Sensitive Amperometric Detection of Cholesterol in Real Samples10.1016/j.bios.2010.12.009 ↗
6. Nanostructures in Hydrogen Peroxide Sensing10.3390/s21062204 ↗
7. Nanomaterials Based Electrochemical Sensors for Biomedical Applications10.1039/c3cs35518g ↗
8. Recent Advances in Electrochemical Sensing for Hydrogen Peroxide: A Review10.1039/C1AN15738H ↗
9. Cholesterol Oxidase from Streptomyces Hygroscopicus and Brevibacterium Sterolicum: Effect of Surfactants and Organic Solvents on Activity10.1111/j.1470-8744.1999.tb01155.x ↗
10. Development of a Sensitive Electrochemical Enzymatic Reaction-Based Cholesterol Biosensor Using Nano-Sized Carbon Interdigitated Electrodes Decorated with Gold Nanoparticles10.3390/s17092128 ↗
11. Recent Advances in Cholesterol Biosensor10.1016/j.bios.2007.10.018 ↗
12. Electrochemical Operational Principles and Analytical Performance of Pd-Based Amperometric Nanobiosensors10.1039/D1AN00882J ↗
13. Investigation of the Binding Kinetics and Electrochemical Properties of in Situ Reconstructed Apo-GOx Using Electrodes with Electrodeposited10.1039/D5AN00337G ↗
14. Amperometric Biosensors Based on Direct Electron Transfer Enzymes10.3390/molecules26154525 ↗
15. Direct Electron Transfer from Glucose Oxidase Immobilized on an Overoxidized Polypyrrole Film Decorated with Au Nanoparticles10.1016/j.colsurfb.2012.11.010 ↗
16. Noble Metal Nanoparticles in Biosensors: Recent Studies and Applications10.1515/ntrev-2016-0014 ↗
17. Direct Electron Transfer of Cellobiose Dehydrogenase on Positively Charged Polyethyleneimine Gold Nanoparticles10.1002/cplu.201600453 ↗
18. One-Step Electrodeposited Hybrid Nanofilms in Amperometric Biosensor Development10.1039/D4AY00290C ↗
19. Electrochemical Operational Principles and Analytical Performance of Pd-Based Amperometric Nanobiosensors10.1039/D1AN00882J ↗
20. Mechanistic Aspects of Glycerol Oxidation on Palladium Electrocatalysts in Model Aqueous and Fermentation Media Solutions10.1016/j.electacta.2024.144479 ↗
21. First Principles of Hydrazine Electrooxidation at Oxide-Free and Oxide-Based Palladium Electrodes in Complex Media10.1039/D3CP00829K ↗
22. The Influence of the Enzyme Membrane Thickness on the Response of Amperometric Biosensors10.3390/s30700248 ↗
23. A Colorimetric Nanoprobe Based on Enzyme-Immobilized Silver Nanoparticles for the Efficient Detection of Cholesterol10.1039/C9RA08328F ↗
24. Purification, Characterization and Amino Acid Content of Cholesterol Oxidase Produced by Streptomyces Aegyptia NEAE 10210.1186/s12866-017-0988-4 ↗
25. Steady-State Oxidation of Cholesterol Catalyzed by Cholesterol Oxidase in Lipid Bilayer Membranes on Platinum Electrodes10.1016/j.aca.2004.03.030 ↗
26. Measurement of the Mass Sensitivity of QCM with Ring Electrodes Using Electrodeposition10.1016/j.elecom.2020.106744 ↗
27. Accelerated Electron Transfer in Nanostructured Electrodes Improves the Sensitivity of Electrochemical Biosensors10.1002/advs.202102495 ↗
28. Fundamentals, Applications, and Future Directions of Bioelectrocatalysis10.1021/acs.chemrev.0c00472 ↗
29. Direct Electrochemical Enzyme Electron Transfer on Electrodes Modified by Self-Assembled Molecular Monolayers10.3390/catal10121458 ↗
30. Immobilization of Glucose Oxidase into a Nanoporous TiO2 Film Layered on Metallophthalocyanine Modified Vertically-Aligned Carbon Nanotubes for Efficient Direct Electron Transfer10.1016/j.bios.2013.02.029 ↗
31. Electrochemical Biosensors: Towards Point-of-Care Cancer Diagnostics10.1016/j.bios.2005.10.027 ↗
32. Amperometric Biosensor for Cholesterol Based on Novel Nanocomposite Array Gold Nanoparticles/Acetone-Extracted Propolis/Multiwall Carbon Nanotubes/Gold10.1049/mnl.2013.0664 ↗
33. Development of an Amperometric Cholesterol Biosensor Based on Graphene-Pt Nanoparticle Hybrid Material10.1021/jp105895a ↗
34. Development of Highly Sensitive and Selective Cholesterol Biosensor Based on Cholesterol Oxidase Co-Immobilized with α-Fe2O3Micro-Pine Shaped Hierarchical Structures10.1016/j.electacta.2014.04.173 ↗
35. Enzyme-Based Biosensors: Tackling Electron Transfer Issues10.3390/s20123517 ↗
36. Direct Electrochemistry of Redox Proteins and Enzymes Promoted by Carbon Nanotubes10.3390/s5040220 ↗
37. Self-Assembled Glucose Oxidase/Graphene/Gold Ternary Nanocomposites for Direct Electrochemistry and Electrocatalysis10.1016/j.jelechem.2013.03.001 ↗
38. Biomimetic and Bioinspired Approaches for Wiring Enzymes to Electrode Interfaces10.1039/C6EE02801B ↗