Inversion of Contrast in Ferroelectric Smectic C Liquid Crystal Displays
Source abstract
Abstract
Abstract Contrast inversion has been observed in ferroelectric smectic C liquid crystal displays when multiplexed using a standard two-slot multiplexing scheme. This occurs when the switching response moves from the trailing half of the double pulse to the leading half at relatively high voltages and short time slots. The effect is explained with reference to the voltage-time switching dependency. Some important implications for multiplexing are pointed out.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Liquid Crystal Research Advancements · Photonic Crystals and Applications · Advanced Optical Imaging Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (6)
Show source-provided references
1. Harada, T., Taguchi, M., Iwasa, K. and Kai, M. Proc. SID Int. Symp. Dig. pp.131
2. Lagerwall, S. T., Wahl, J. and Clark, N. A. Proc. Int. Display Research Conference, I.E.E.E. pp.213
3. 10.1080/0267829870808664210.1080/02678298708086642 ↗
4. Bishop, D., Jenner, J. A. and Sage, I. C. 11th International Liquid Crystal Conference. Berkeley, U.S.A.
5. 10.1088/0022-3735/19/9/00510.1088/0022-3735/19/9/005 ↗
6. Shimoda, S., Ito, K., Harada, T., Taguchi, M., Iwasa, K. and Kai, M. Proc. Japan Display ′86, Paper 12.2. pp.460